ELECTRIC / UTILITY SYMBOLS: <br />SINGLE POLE SWITCH @ 42" HIGH W/DIMMER <br />GROUND FAULT CIRCUIT INTERRUPTED DUPLEX OUTLET <br />SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE <br />FLUORESCENT SURFACE <br />240V OUTLET - GFI IN GARAGE <br />(INSTALL HIGH EFFICACY LIGHTING) <br />CLG. FAN & LIGHT <br />WALL HUNG FIXTURE WITH CFL OR LED LIGHTING U.N.O. (See Plans for Type) <br />RECESSED DOWN LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING) <br />CEILING LIGHT FIXTURE HIGH EFFICACY (CFL OR LED LIGHTING) <br />ARC FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET <br />SMOKE DETECTOR HARDWIRED TO HOUSE CIRCUITRY IN TANDEM <br />AND PROVIDE BATTERY BACK-UP SYSTEM. <br />D <br />WEATHERPROOF OUTLET - G.F.C.I. W/IN-USE COVER <br />CARBON MANOXIDE ALARMS <br />w/ms-pc <br />WALL MOUNTED MOTION SENSOR W/ PHOTO CONTROL FIXTURE <br />OUTDOOR LIGHTING SHALL BE HIGH-EFFICACY. <br />C.M. <br />S <br />S V <br />WP/ <br />GFI/C <br />BATHROOM EXHAUST FAN SHALL BE ENERGY STAR RATED AND EQUIPPED <br />RATED AND EQUIPPED WITH HUMIDISTAT (2022 CGBC) <br />GFCI <br />SEE LAMP SUPPORT NOTE <br />240 <br />GARAGE DOOR OUTLETGD <br />VACANCY SENSOR, SEE ENERGY CONSERVATION NOTE #1 SHEET E-1. <br />ENERGY STORAGE SYSTEM (ESS) NOTE: <br />Energy storage system (ESS) per (CEnC 150.0) (S). <br />At least one shall be provided: ESS ready interconnection <br />equipment with minimum backed up capacity of 60A and 4 ESS <br />supplied branch circuits. Dedicated raceway from main service to <br />sub-panel that supplies branch circuits. B. Identify at least 4 <br />branch circuits for emergency use (supply refrigerator, lighting <br />near front door, one outlet in bedroom). C. Space for future <br />system isolation equipment or transfer switch within 3 feet of main <br />panel as well as raceways installed between panel and system <br />isolation equipment or transfer switch location to allow the <br />connection of backup power source. <br />2022 ENERGY REQUIREMENTS FOR NEW ADU <br />Residential Energy ESS <br />l. At least one of the following shall be provided to demonstrate compliance with <br />energy storage system ready dwellings. Per CEnC Section 150.0(s)l: <br />a. ESS ready interconnection equipment with a minimum backed-up capacity of 60 <br />amps and a minimum of four ESS-supplied branch circuits, or; <br />b. The future location of a system isolation equipment / transfer switch and ensure a <br />clear space be reserved to allow installation within 3 feet of the main panel <br />board. See plan for proposed location. <br />2. Per CEnC Section 150.0(s)2; <br />"A minimum of four branch circuits shall be identified and have their source of supply <br />collocated at a single panel board suitable to be supplied by the ESS. At least one <br />circuit shall supply the refrigerator, one lighting circuit shall be located near the <br />primary egress and at least one circuit shall supply a sleeping room receptacle outlet." <br />3. Provide an electrical panel board with a minimum busbar rating of 200-Amps. [CEnC <br />150.0(s)3] <br />4. For the future energy storage system, sufficient space shall be reserved to allow <br />future installation of a system isolation equipment/transfer switch within 3 feet of the <br />main panel board. Raceways shall be installed between the panel board and the system <br />isolation equipment / transfer switch location to allow the connection of backup power <br />source. See plan for proposed location. [CEnC 150.0(s)4]. <br />Residential ENERGY ELECTRIC-READY. <br />1.Where gas appliances such as cooking range, dryer, etc. are proposed, provide <br />a dedicated 220-volt receptacle outlet on the plan to serve the appliance. See plan <br />for proposed locations. <br />2.Systems using gas or propane furnace to serve individual dwelling units shall <br />include the following to be heat pump space heater ready per CEnC Section 150.0(t): <br />a.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from <br />the furnace and accessible to the furnace with no obstructions. The branch <br />circuit conductors shall be rated at 30 amps minimum. The blank cover shall be <br />identified as "240V read." AII electrical components shall be installed in <br />accordance with the California Electrical Code. <br />b.The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future heat pump space heater <br />installation. The reserved space shall be permanently marked as "For Future <br />240V use." <br />3.Systems using gas or propane cooktop to serve individual dwelling units shall <br />include the following to be electric cooktop ready per CEnC Section 150.0(u): <br />a.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from <br />the cooktop and accessible to the cooktop with no obstructions. The branch <br />circuit conductors shaII be rated at 30 amps minimum. The blank cover shall be <br />identified as "240V ready." AII electrical components shall be installed in <br />accordance with the California Electrical Code. <br />b.The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future electric cooktop <br />installation. The reserved space shall be permanently marked as "For Future <br />240V use." <br />4.Clothes dryer locations with gas or propane plumbing to serve individual dwelling <br />units shaII include the following to be electric clothes dryer ready per CEnC Section <br />150.0(v): <br />a.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from <br />the clothes dryer location and accessible to the clothes dryer location with no <br />obstructions. The branch circuit conductor shall be rated at 30 amps minimum. <br />The blank cover shall be identified as "240V ready". All electrical components <br />shall be installed in accordance with the California Electrical Code. <br />b.The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future electric clothes dryer <br />installation. The reserved space shall be permanently marked as "For Future <br />240V use." <br />5.lf the designated space is more than 3 feet from the water heater, then this <br />space shall be include the following per CEnC section 150.0(n)lB: <br />a.A dedicated 240 volt branch circuit shall be installed within 3 feet from the <br />designated space.The branch circuit shall be rated at 30 amps minimum. The <br />blank cover shall be identified as "240V ready"; and <br />b.The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future HPWH installation. The <br />reserved space shall be permanently marked as "For Future 240V use"; and <br />c.Either a dedicated cold water supply, or the cold water supply shall pass <br />through HPWH location just before reaching the gas or propane water heater; <br />and <br />d.The hot water supply pipe coming out of the gas or propane water heater shall <br />be routed first through the designated HPWH location before serving any <br />fixtures; and <br />e.The hot and cold water piping at the designated HPWH location shall be exposed <br />and readily accessible for future installation of an HPWH; and <br />f.A condensate drain that is no more than 2 inches higher than the base of the <br />installed water heater, and allows natural draining without pump assistance. <br />IAQ FAN = 42 CFM (EACH UNIT)IAQ FAN <br />see T-24 Calc's <br />(UNITS) HVAC NOTE: HEAT PUMP SYSTEM REQUIRED. SEER 16 / HSPF 9. SEE T-24 CALC's. <br />APPLIANCES MODELING <br />GAS: KITCHEN RANGE, DRYER. <br />ELECTRICAL: WATER HEATER HEAT PUMP. <br />HVAC. <br />NOTE: <br />GAS APPLIANCES SHALL COMPLY WITH THE <br />ELECTRICAL READY REQUIREMENTS. <br />SEE RESIDENTIAL ENERGY ESS REQUIREMENTS. <br />(UNITS) HPWH NOTE: HEAT PUMP SYSTEM REQUIRED. RHEEM XE40T10H22U0 (40gal, JA13). <br />SEE T-24 CALC's. High-Efficiency Heat Pump. <br />ELECTRICAL PLANS <br />OWNER/CLIENT <br />PROJECT LOCATION <br />PROJECT TITLE <br />SHEET TITLE <br />DATE <br />AS SHOWN <br />SCALE <br />02 / 24 <br />D R A F T I N G S E R V I C E <br />TE <br />L <br /> <br />: <br /> <br /> <br /> <br />( <br />9 <br />5 <br />1 <br />) <br /> <br />9 <br />9 <br />2 <br />- <br />7 <br />2 <br />3 <br />4 <br />ju <br />a <br />n <br />. <br />g <br />o <br />n <br />z <br />a <br />l <br />e <br />z <br />. <br />1 <br />9 <br />7 <br />1 <br />@ <br />h <br />o <br />t <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />FI <br />N <br />. <br />G <br />. <br />S <br />& <br /> <br />P <br />WA <br />R <br />D <br />F. <br />M <br />. <br />C <br />. <br />FR <br />. <br /> <br />D <br />R <br />. <br /> <br />VL <br />. <br /> <br />S <br />L <br />. <br />KE <br />E <br />P <br /> <br />L <br />A <br />B <br />E <br />L <br /> <br />O <br />N <br /> <br />T <br />H <br />E <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />H <br />E <br />A <br />T <br />E <br />R <br />3. <br /> <br /> <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />5 <br />0 <br /> <br />G <br />A <br />L <br />L <br />O <br />N <br />S <br /> <br />M <br />I <br />N <br />. <br />1. <br /> <br /> <br /> <br />A <br />L <br />L <br /> <br />H <br />O <br />R <br />I <br />Z <br />O <br />N <br />T <br />A <br />L <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br /> <br />D <br />R <br />Y <br />W <br />A <br />L <br />L <br /> <br />A <br />P <br />P <br />L <br />I <br />E <br />D <br /> <br />T <br />O <br /> <br />T <br />R <br />U <br />S <br />S <br />E <br />S <br />2. <br /> <br /> <br /> <br />A <br />L <br />L <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />S <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />W <br />H <br />I <br />T <br />E <br />. <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />P <br />L <br />A <br />N <br /> <br />FO <br />R <br /> <br />S <br />I <br />Z <br />E <br /> <br />A <br />N <br />D <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />E <br />L <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br /> <br />F <br />O <br />R <br /> <br />A <br />L <br />L <br /> <br />B <br />R <br />E <br />A <br />K <br />- <br />U <br />P <br />S <br />SH <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />5 <br />/ <br />8 <br />" <br /> <br />G <br />Y <br />P <br />S <br />U <br />M <br /> <br />B <br />O <br />A <br />R <br />D <br />SI <br />N <br />G <br />L <br />E <br /> <br />H <br />U <br />N <br />G <br />OP <br />T <br />I <br />O <br />N <br />A <br />L <br />SL <br />I <br />D <br />E <br />R <br /> <br />O <br />R <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br />FI <br />X <br />E <br />D <br /> <br />G <br />L <br />A <br />S <br />S <br />CE <br />I <br />L <br />I <br />N <br />G <br />EL <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br />F. <br />G <br />. <br />S. <br />H <br />. <br />SL <br />. <br />OP <br />T <br />. <br />CL <br />' <br />G <br />. <br />EL <br />E <br />V <br />. <br />W/ <br />SH <br />E <br />L <br />F <br /> <br />& <br /> <br />P <br />O <br />L <br />E <br />FR <br />E <br />N <br />C <br />H <br /> <br />D <br />O <br />O <br />R <br />FL <br />O <br />O <br />R <br /> <br />M <br />A <br />T <br />E <br />R <br />I <br />A <br />L <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br />FI <br />N <br />I <br />S <br />H <br /> <br />G <br />R <br />A <br />D <br />E <br />WI <br />T <br />H <br />WA <br />R <br />D <br />R <br />O <br />B <br />E <br />VI <br />N <br />I <br />L <br /> <br />S <br />L <br />I <br />D <br />E <br />R <br />G& <br />S <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />a <br />l <br /> <br />D <br />e <br />s <br />i <br />g <br />n <br /> <br />a <br />n <br />d <br /> <br />P <br />l <br />a <br />n <br />n <br />i <br />n <br />g <br />JU <br />A <br />N <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />12 <br />5 <br />9 <br />4 <br /> <br />M <br />i <br />c <br />h <br />i <br />g <br />a <br />n <br /> <br />S <br />t <br />, <br /> <br />G <br />r <br />a <br />n <br />d <br /> <br />T <br />e <br />r <br />r <br />a <br />c <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />3 <br />1 <br />3 <br />AB <br />B <br />R <br />E <br />V <br />I <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />TY <br />P <br />I <br />C <br />A <br />L <br /> <br /> <br />N <br />O <br />T <br />E <br />S <br />PL <br />A <br />N <br />S <br /> <br />P <br />R <br />E <br />P <br />A <br />R <br />E <br /> <br />B <br />Y <br />: <br />SHEET <br />Mailing address: <br />JC IMP EXP INC <br />14881 ALDER LN, TUSTIN, <br />CA 92780-6742 <br />PROPOSED (2) TWO NEW <br />ADU's. <br />NOTE: <br />MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN <br />REVIEW AND APPROVAL. <br />MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. <br />(N) <br />C.M. <br />(N) <br />LaundrySee elec & mech <br />notes sheet E-1 <br />FU <br />R <br />N <br />A <br />C <br />E <br />(N) <br />(N) <br />See elec & <br />mech notes E-1 <br />Kitchen <br />Bedroom 2 <br />Bedroom 1 <br />Bath <br />See elec & mech <br />notes sheet E-1 <br />ACCESS <br />(N) <br />Dining <br />(N) <br />Living <br />(N)Sub Panel. <br />See E-1 <br />ELECTRICAL PLAN (UNIT#100 & UNIT#101) <br />1/4" = 1'-0" <br />cl <br />o <br />s <br />e <br />t <br />st <br />o <br />v <br />e <br />ADU #101 <br />NEW UNIT #101 <br />C.M. <br />(N) <br />FU <br />R <br />N <br />A <br />C <br />E <br />See elec & <br />mech notes E-1 <br />Kitchen <br />ACCESS <br />cl <br />o <br />s <br />e <br />t <br />st <br />o <br />v <br />e <br />ADU #100 <br />A. <br />A <br />. <br />M <br />e <br />t <br />a <br />l <br /> <br />A <br />t <br />t <br />i <br />c <br /> <br />S <br />t <br />a <br />i <br />r <br />s <br />pe <br />r <br /> <br />M <br />a <br />n <br />u <br />f <br />a <br />c <br />t <br />u <br />r <br />e <br />d <br />. <br />Sa <br />f <br />e <br /> <br />S <br />t <br />e <br />p <br /> <br />S <br />t <br />a <br />i <br />r <br />. <br />(N) <br />Front porch <br />(N) <br />Rear cover patio <br />(N) <br />Rear cover patio <br />IAQ in ATTIC <br />see T-24 calc's & <br />elec plans <br />SEE LAMP <br />SUPPORT NOTE <br />20'-0" MAX. <br />F.C.U. <br />30"x30" ATTIC ACCESS <br />CORROSION-RESISTANT PAN <br />SHT. MTL. <br />SET 0/ 26 GA <br />COLD AIR RETURN <br />ROOF RAFTER <br />PLYWOOD PLATFORM BY TRUSS <br />ATTIC - MOUNTED <br />DOUBLE - WALLED <br />VENT CONNECTORS <br />FRONT OF CONTROL <br />SIDE OF UNIT <br />2x PLATFORM <br />12" INSOLATION DAM <br />TILE 24 CALC'S <br />ISULATION PER <br />FRAMING <br />WALKWAY (un-obstructed) <br />24" WIDE CONT. PLYWOOD <br />MANUFACTURER <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />LIGHT <br />1" CLR. MIN <br />WORKSPACE IN <br />30' CLEAR <br />CLASS "B" VENT W/ 26 GA. <br />GALV. FLASHING COLLAR <br />PROVIDED W/ 1/4" SCREENING <br />PROVIDE GAS & OUTLET AT IN <br />ATTIC FOR F.C.U. <br />COMBUSTION & SUPPLY AIR <br />PROVIDE SEPARATE DUCT <br />OPENINGS FOR UPPER & LOWER <br />PROVIDE CIRCULATING AIR SUPPLY <br />OPENINGS OR DUCT W/ 2 SQ. IN. <br />PER 1000 BTU (100 SQ. IN. MIN.) <br />TO COMPARTMENT TO BE <br />NOTES : <br />COMBUSTION AIR FORM OUTSIDE <br />A MINIMUM 22"x30" ATTIC ACCESS <br />SHALL BE PROVIDED INTO ALL ATTIC <br />AREAS. <br />ACCESS SHALL BE LOCATED WITHIN 20' <br />OF ATTIC MOUNTED EQUIPMENT. <br />CATWALK FROM ACCESS OPENING TO <br />EQUIPMENT SHALL BE UNOBSTRUCTED <br />BY TRUSS MEMBERS OR OTHER <br />FEATURES. <br />MINIMUM 30" HEADROOM SHALL BE <br />MAINTAINED AT ACCESS, CATWALK AND <br />WORK AREA. <br />OUTLET <br />SWITCH <br />WP <br />/ <br />GF <br />I <br />/ <br />C <br />GF <br />I <br />/ <br />C <br />w/ms-pc <br />w/ms-pc <br />w/ms-pc <br />w/ms-pc <br />WP <br />/ <br />GF <br />I <br />/ <br />C <br />WP <br />/ <br />GF <br />I <br />/ <br />C <br />(N)Sub Panel. <br />See E-1 <br />EXHAUST 4"d VENT TO <br />OUT W/BACK-DRAFT <br />DAMPER <br />(N) Hyb HW. <br />See T-24 Calc's. <br />See elec, plmbg & mech <br />notes. <br />See Water Heater <br />Components note sheet E-1. <br />Provide water heater <br />disconnect <br />240 <br />GFI <br />(N) <br />Attic space UNIT #101. <br />A. <br />A <br />. <br />Me <br />t <br />a <br />l <br /> <br />A <br />t <br />t <br />i <br />c <br /> <br />S <br />t <br />a <br />i <br />r <br />s <br /> <br />p <br />e <br />r <br />Ma <br />n <br />u <br />f <br />a <br />c <br />t <br />u <br />r <br />e <br />d <br />. <br />Sa <br />f <br />e <br /> <br />S <br />t <br />e <br />p <br /> <br />S <br />t <br />a <br />i <br />r <br />. <br />(N) <br />Attic space UNIT #100. <br />A. <br />A <br />. <br />Me <br />t <br />a <br />l <br /> <br />A <br />t <br />t <br />i <br />c <br /> <br />S <br />t <br />a <br />i <br />r <br />s <br /> <br />p <br />e <br />r <br />Ma <br />n <br />u <br />f <br />a <br />c <br />t <br />u <br />r <br />e <br />d <br />. <br />Sa <br />f <br />e <br /> <br />S <br />t <br />e <br />p <br /> <br />S <br />t <br />a <br />i <br />r <br />. <br />ATTIC ELECTRICAL PLAN (UNIT#100 & UNIT#101) <br />1/4" = 1'-0" <br />GFI <br />EXHAUST 4"d VENT TO <br />OUT W/BACK-DRAFT <br />DAMPER <br />(N) Hyb HW. <br />See T-24 Calc's. <br />See elec, plmbg & mech <br />notes. <br />See Water Heater <br />Components note sheet E-1. <br />Provide water heater <br />disconnect <br />240 <br />GFI <br />GFI <br />S <br />V <br />S <br />V <br />S SSee elec, plumbg <br />& mech notes E-1 See elec, plumbg <br />& mech notes E-1 <br />cl <br />o <br />s <br />e <br />t <br />cl <br />o <br />s <br />e <br />t <br />SEE LAMP <br />SUPPORT NOTE <br />SS <br />D <br />SS <br />D <br />Vacancy <br />Sensor <br />GFI <br />VS <br />S <br />V <br />S <br />S <br />4" EXHAUST DUCT <br />UP THRU ROOF <br />CONNECT TO <br />ROOF JACK. MIN <br />50 CFM FAN <br />Humidity Control. <br />See Mechanical <br />Note <br />SS <br />S <br />S <br />4" EXHAUST DUCT SHALL TERMINATE NO <br />LESS THAN 3'-0" FROM OPENINGS INTO <br />THE BUILDING (502.2.1 CMC) <br />Provide under counter <br />for garbage disposal <br />GFI <br />240 <br />Kitchen exhaust shall be Min <br />180 CFM for gas stove. Per <br />2022 BEES table 150.0G <br />GF <br />I <br />GFI <br />GFI <br />GFIGF <br />I <br />GF <br />I <br />S <br />EXHAUST 4"d METAL SMOOTH VENT <br />TO OUT W/BACK-DRAFT DAMPER <br />4" DRYER EXHAUST DUCT SHALL <br />TERMINATE NO LESS THAN 3'-0" FROM <br />OPENINGS INTO THE BUILDING (502.2.1 <br />CMC) SEE ELEC & MECH NOTES <br />S S <br />V <br />Vacancy <br />Sensor <br />DRYER VENT <br />KITCHEN VENT <br />SS <br />EXHAUST 4"d METAL SMOOTH VENT <br />TO OUT W/BACK-DRAFT DAMPER <br />4" DRYER EXHAUST DUCT SHALL <br />TERMINATE NO LESS THAN 3'-0" FROM <br />OPENINGS INTO THE BUILDING (502.2.1 <br />CMC) SEE ELEC & MECH NOTES <br />S <br />S <br />S <br />(N) <br />Bedroom 1 <br />SEE LAMP <br />SUPPORT NOTE <br />SS <br />D <br />SS <br />D <br />(N) <br />Bedroom 2 <br />SEE LAMP <br />SUPPORT NOTE <br />Vacancy <br />Sensor <br />GFI <br />V <br />S <br />S <br />V <br />S <br />S <br />4" EXHAUST DUCT <br />UP THRU ROOF <br />CONNECT TO <br />ROOF JACK. MIN <br />50 CFM FAN <br />Humidity Control. <br />See Mechanical <br />Note <br />24 <br />0 <br />LaundrySee elec & mech <br />notes sheet E-1 S SV <br />Vacancy <br />Sensor <br />24 <br />0 <br />(N) <br />Bath <br />See elec & mech <br />notes sheet E-1 <br />A. <br />A <br />. <br />M <br />e <br />t <br />a <br />l <br /> <br />A <br />t <br />t <br />i <br />c <br /> <br />S <br />t <br />a <br />i <br />r <br />s <br />pe <br />r <br /> <br />M <br />a <br />n <br />u <br />f <br />a <br />c <br />t <br />u <br />r <br />e <br />d <br />. <br />Sa <br />f <br />e <br /> <br />S <br />t <br />e <br />p <br /> <br />S <br />t <br />a <br />i <br />r <br />. <br />(N) <br />Front porch <br />Provide under counter <br />for garbage disposal <br />GF <br />I <br />GF <br />I <br />GF <br />I <br />GFI <br />240 <br />GFI <br />GFI <br />GFI <br />(N) <br />Dining <br />(N) <br />Living <br />NEW UNIT #100 <br />IAQ in ATTIC <br />see T-24 calc's & <br />elec plans <br />2010 AND 2012 N BUSH <br />AVE #100 AND #101, SANTA <br />ANA, CA 92706-2818 <br />05-E-2 <br />REG <br />ISTERED PROF E S S IONAL ENGI <br />NE <br />ER <br />STATE OF CAL IFORNIA <br />NO. C-31397 <br />EXP. 12/31/2024 <br />C I V I L <br />LEO A . A GUILERA <br />2010 & 2012 N Bush Ave, <br />#100 and #1012/21/2025