Laserfiche WebLink
SCOPE:SCOPE: <br />DATE:11/19/2024 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />OMAR NASSER <br />NAME: DOUG RISK <br />ADDRESS: 2309 NORTH SPURGEON <br />STREET, SANTA ANA, CA 92706 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />COMPANY NAME: TREEPUBLIC <br />LICENSE:# 996593 <br />ADDRESS: 3521 JACK NORTHROP AVE, <br />HAWTHORNE CA 90250 <br />PHONE: (800) 701-8073 <br />6.56 KW DC Roof Mounted <br />PV Electrical System <br />16 - Solarever 410W PV Modules <br />1 - Tigo 11.4KW Inverter <br />2 - Tesla Powerwall 3 Battery <br />TWO STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' TRUSSES 24'' O/C <br />CONSTRUCTION TYPE:V-B <br />OCCUPANCY GROUP: R3 <br />FIRE SPRINKLERS: NO <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 00307232 <br />LOT AREA: 6,000 SQFT <br />LIVING AREA: 2,614 SQFT <br />PV-2 <br />THREE LINE DIAGRAM <br />NOTE: Photovoltaic system is rapid shut down ready <br />1 2 9 <br />INV <br />G N L2 L1 <br />EXISTING CONDUIT <br />EXISTING ABB 3.6KW <br />(PVI-3.6-OUTD-S-US-Z-A) <br />INVERTER <br />EXISTING <br />3/4'' EMT CONDUIT <br />(3) THWN-2, #10 (L1, L2, N) <br />(1) #8, EGC CU <br />1 2 10 <br />TESLA <br />POWERWALL <br />3 <br />L1 <br />L2 <br />N <br />GG <br />- <br />+ <br />- <br />+ <br />TESLA <br />BATTERY <br />TESLA <br />POWERWALL <br />3 <br />L1 <br />L2 <br />N <br />GG <br />- <br />+ <br />- <br />+ <br />TESLA <br />BATTERY <br />NEW <br />3/4'' EMT CONDUIT <br />(3) THWN-2, #6 (L1, L2, N) <br />(1) #8, EGC CU <br />L1 <br />L2 <br />G <br />L1 <br />L2 <br />G <br />N N <br />8 <br />NEW <br />3/4'' EMT CONDUIT <br />(3) THWN-2, #6 (L1, L2, N) <br />(1) #8, EGC CU <br />L1 <br />L2 <br />G <br />L1 <br />L2 <br />G <br />N N <br />N <br />G <br />L2L1 <br />L2 <br />L1 <br />CTRL <br />L2 <br />L1 <br />L1 <br />L1 <br />L2 <br />L1 <br />L2 <br />L1 <br />L2 <br />L1 <br />L1 <br />L1 <br />L2 <br />L2 <br />L2 <br />N <br />G <br />L2 <br />N <br />G <br />NEW 60A <br />BREAKER <br />NOTE: AFCI PROTECTION IS REQUIRED <br />FOR CIRCUITS RELOCATED MORE <br />THAN 6 FT. PER SECT. 210.12(B). <br />NEW WIRING <br />2'' EMT CONDUIT <br />(3) THWN-2, #3/0 (L1, L2, N) <br />(1) #4, EGC CU <br />NEW 200A <br />OCPD <br />L2 <br />L1 <br />L2 <br />L1 <br />L1 <br />L2 <br />G <br />L1 <br />L2 <br />G <br />N N <br />1 2 8 <br />INV <br />G N L2 L1 <br />EXISTING SOLAR SYSTEM <br />(19) JA SOLAR 395W MODULES <br />TIGO 11.4KW <br />(TSI-11.4K-US) <br />INVERTER <br />1 2 8 <br />L1 <br />L2 <br />G <br />L1 <br />L2 <br />G <br />N N <br />1 <br />2 <br />6 <br />4 <br />7 <br />5 <br />8 <br />9 <br />9 <br />10 <br />11 <br />INSTALL 2P <br />20A CB(PV) <br />FURTHEST FROM <br />MAIN FEEDER CB <br />8' Minimum Embedment Rod at 6' <br />From Equipment Ground Conductor Unless <br />Existing Ground is UFER. <br />N <br />G <br />M <br />L1 <br />L1 <br />N L2 <br />N L2 <br />N <br />L2 <br />L1 <br />L1 <br />L2 <br />EXISTING 200A <br />CENTER FEED OCPD <br />TO UTILITY GRID <br />NEW 2P 200A <br />12 <br />NOTE: 705.12.(B)(3)(3) <br />connection method will be used. <br />A <br />B <br />ELECTRICAL EQUIPMENT INFORMATION <br />#Quantity Description <br />-19 (E) JA SOLAR 395W (JAM54S31-395/MR) Modules <br />1 16 (N) Solarever 410W (SE-182*91-410M-108) Modules <br />2 16 (N) TIGO TS4-A-O Optimizers <br />3 1 (N) Junction-Box <br />4 1 (E) ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) (120/240V) Inverter <br />5 1 (E) 30A Non-Fused AC Disconnect (120/240V) <br />6 1 (N) TIGO 11.4KW (TSI-11.4K-US) (120/240V) Inverter <br />7 1 (N) 60A Non-Fused AC Disconnect (120/240V) <br />8 2 (N) 11.5 kW TESLA POWERWALL 3 1707000-xx-y (120/240V) <br />(All-In-One Solar & Battery System (DC-Coupled Solar)) (Page D-1) <br />9 2 (N) 60A Non-Fused AC Disconnect (120/240V) <br />10 1 (N) Tesla Backup Gateway 2 (120/240V) (Page D-2) <br />11 1 (N) 200A Back-up Load Panel (120/240V) <br />12 1 (E) 200A Main Service Panel (120/240V) <br />3 <br />J/B <br />C C <br />STRINGS A,B <br />(8) SOLAREVER 410W MODULES <br />(8) TIGO TS4-A-O OPTIMIZERS STRING CALCULATION <br />Number of <br />Modules <br />Module <br />VOC Coefficient Total Inp. <br />Voltage <br />Max Inp. <br />Voltage <br />8 37.12 1.12 332.6V <=600V <br />[1] <br />[2] <br />[5] <br />EXISTING ABB RAPID <br />SHUTDOWN DEVICE <br />SEE PAGE D-16 <br />[6] <br />Rerouted circuits will be 10 x #8 wires, and 33 x #10 wires <br />Multiple conduit will be used 1 x 1 1/4'' EMT and 3 x 1'' EMT Conduits <br />[7] <br />2309 N Spurgeon <br />St12/11/2024