My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2309 N Spurgeon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
2309 N Spurgeon St
>
2309 N Spurgeon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:51:20 PM
Creation date
6/6/2025 1:20:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20184262
Full Address
2309 N Spurgeon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). <br />2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC310.10(C). <br />3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. <br />4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO CEC <br />240.6 CODE SECTION. <br />6.AC GROUNDING ELECTRODE CONDUCTOR SIZED PER CEC 250.66. <br />7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(A). <br />8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2). <br />9.MAX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. <br />10.CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE CEC 310.15(B)(16). <br />SCOPE:SCOPE: <br />DATE:11/19/2024 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />OMAR NASSER <br />NAME: DOUG RISK <br />ADDRESS: 2309 NORTH SPURGEON <br />STREET, SANTA ANA, CA 92706 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />COMPANY NAME: TREEPUBLIC <br />LICENSE:# 996593 <br />ADDRESS: 3521 JACK NORTHROP AVE, <br />HAWTHORNE CA 90250 <br />PHONE: (800) 701-8073 <br />6.56 KW DC Roof Mounted <br />PV Electrical System <br />16 - Solarever 410W PV Modules <br />1 - Tigo 11.4KW Inverter <br />2 - Tesla Powerwall 3 Battery <br />TWO STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' TRUSSES 24'' O/C <br />CONSTRUCTION TYPE:V-B <br />OCCUPANCY GROUP: R3 <br />FIRE SPRINKLERS: NO <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 00307232 <br />LOT AREA: 6,000 SQFT <br />LIVING AREA: 2,614 SQFT <br />PV-3 <br />ELECTRICAL CALCULATION <br />WIRE SIZE CALCULATION <br />WIRE TAG#WIRE TYPE <br />AND SIZE <br /> QUANTITY OF <br />WIRES <br />GROUNDING <br />SIZE <br />WIRE <br />AMPACITY TEMPERATURE CONDUIT TYPE ABOVE ROOF TEMP. DERATE <br />FACTOR ADJUSTING FACTOR <br />CORRECTED <br />CONDUCTOR <br />AMP <br />CURRENT <br />AMP <br />A PV WIRE #10 2 #6, BARE CU 40 A 90°Free in the air >3.5 - 12''0.71 1 N/A 28.4 18.8 <br />B THWN-2 #10 <br />2x(DC+,DC-)4 #8, EGC CU 40 A 90°3/4'' EMT >3.5 - 12''0.71 0.8 4 Thru 6 Wires 22.7 18.8 <br />C THWN-2 #6 <br />(L1,L2,N)3 #8, EGC CU 75 A 90°3/4'' EMT ALONG THE <br />WALL 0.91 1 N/A 68.3 60.0 <br />NEW PV SYSTEM OUTPUT CALCULATION <br />1 TIGO 11.4KW (TSI-11.4K-US)97.5 % <br />16 <br />Solarever 410W (SE-182*91-410M-108)410.0 W <br />Pmax (PTC Rating)380.0 W <br />1 Inverter Output 11400 W <br />Max DC Output 16 * 410.0 6.56 KW <br />Max AC Output 16 * 380.0 * 0.975 5.93 KW <br />Inverters Output:1 * 11400.0 11.40 KW <br />WIRE AMPACITY DC <br />#RSD <br />AMP <br /> CONSIDER <br />CONTINUOUS <br />COEFFICIENT <br />CURRENT <br />AMP <br />A 15 1.25 18.8 <br />B 15 1.25 18.8 <br />WIRE AMPACITY AC <br /># <br />INVERTER <br />MAX <br />OUTPUT <br />CURRENT <br />QUANTITY <br /> CONSIDER <br />CONTINUOUS <br />COEFFICIENT <br />CURRENT <br />AMP <br />C 48.0 1 1.25 60.0 <br />EXISTING PV SYSTEM OUTPUT CALCULATION <br />1 ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A)96.0 % <br />19 <br />JA SOLAR 395W (JAM54S31-395/MR)395.0 W <br />Pmax (PTC Rating)368.7 W <br />1 Inverter Output 3600 W <br />Max DC Output 19 * 395.0 7.51 KW <br />Max AC Output 19 * 368.7 * 0.960 6.73 KW <br />Inverters Output:1 * 3600.0 3.60 KW <br />PANEL SCHEDULE <br />BREAKER <br />AMP PHOLES AMOUNT DESCRIPTION TYPE <br />20 1 1 Light Single <br />20 1 1 Bedroom Light Single <br />20 1 4 Kitchen Light Multi Wire Circuit <br />20 1 4 Kitchen Plug Multi Wire Circuit <br />30 2 1 Dryer - <br />40 2 1 AC Unit - <br />30 2 1 AC Unit - <br />20 1 1 El. Plugs Multi Wire Circuit <br />20 1 1 Washer Multi Wire Circuit <br />20 1 1 Garage Multi Wire Circuit <br />15 1 2 1st Floor Lights Multi Wire Circuit <br />20 1 2 1st Floor Plugs Multi Wire Circuit <br />50 2 1 EV Charger - <br />20 1 1 Bathroom+Bedroom Switch Multi Wire Circuit <br />50 2 1 SPA - <br />[3] <br />Note: All multi-wire circuits to be bundled with a single neutral. <br />[4] <br />2309 N Spurgeon <br />St12/11/2024