My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995 S Standard Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Standard Ave
>
1995 S Standard Ave
>
1995 S Standard Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:20:22 PM
Creation date
6/6/2025 1:20:10 PM
Metadata
Fields
Template:
Plan
Permit Number
101120656
Full Address
1995 S Standard Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 1:20 PM
Modified:
5/30/2025 2:13 PM
Text:
www.hilti.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.1 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />9 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Depal - Anchorage Design <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />9 <br />7/19/2024 <br />6 Warnings <br />• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, <br /> EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the <br /> anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br />• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential <br /> concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout <br /> or pryout strength governs. <br />• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the <br /> Evaluation Service Report for cleaning and installation instructions. <br />• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ <br />• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19, <br /> Section 26.7. <br />Fastening meets the design criteria! <br />1995 S Standard Ave- <br />Concrete Pads10/15/2024
The URL can be used to link to this page
Your browser does not support the video tag.