Laserfiche WebLink
2% <br />W <br />G <br />5% <br />5% <br />5% <br />5% <br />2% <br />2% <br /> <br />2% <br />5% <br />2% <br /> <br />2% <br /> <br />5% <br />5% <br />2% <br />2% <br />2% <br />5%5% <br />5% <br />5% <br />2% <br />2% <br /> <br />2% <br /> <br />2% <br /> <br />W <br />G <br />5% <br />5% <br />5% <br />5% <br />2% <br />2% <br /> <br />2% <br />5% <br />2% <br /> <br />2% <br /> <br />5% <br />5% <br />2% <br />2% <br />2% <br />G <br />W <br />2% <br />2% <br />2% <br />5% <br />2% <br />5% <br />5% <br />5%2% <br />2%2% <br />1 <br />(N) ELECTRICAL SUB-PANEL 225AMPS FOR ADU <br />2 PERIMETER FENCE / BLOCK WALL <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />(E) WALK WAY <br />LANDSCAPE <br />(E) TREE <br />(N) CONSUMER TANK WITH/ HEAT PUMP <br />(E) GATE <br />17 <br />(N) HEAT PUMP UNIT ON 3''. THK CONCRETE PAD <br />(E) MAIN HOUSE ELECTRICAL PANEL V.I.F <br />(E) WATER METER <br />(N) ELECTRICAL METER FOR ADU <br />(E) GAS METER V.I.F <br />3 <br />ROOF LINE ABOVE <br />(N) LANDING <br />18 <br />(N) GAS METER <br />(N) WATER METER (1" MINIMUM PER CITY REQUIREMENTS) <br />(E) A/C UNIT V.I.F <br />(E) POST <br />13 <br />14 <br />15 <br />16 <br />19 (N) 6X6 POST <br />20 <br />21 <br />1-HR FIRE RESISTANT EAVE PROJECTION SEE DETAIL 05/AD.20 & 01/AD.20 <br />PROVIDE 2-2X FULL HEIGHT FIRE BLOCKING FROM TOP PLATE TO UNDERSIDE <br />OF EXISTING ROOF SHEATHING, NO VENT HOLE ALLOWED. <br />22 1-HR FIRE RATED WALL, SEE SHEET 01/AD20 FOR DETAIL. <br />23 (N) DRIVE WAY <br />23 ELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH <br />CIRCUIT (40 AMP) <br />1 <br />DRAINAGE DIRECTION AND SLOPE <br />PROPERTY LINE CORNER POINTS AND ELEVATION DATUM <br />#KEYNOTE CALLOUTS <br />EXISTING TO BE REMAINED AND NEW CONSTRUCTION <br />EXISTING TO BE DEMOLISHED <br />F.S.D <br />F.S.L <br />FIRE SEPARATION DISTANCE <br />FIRE SEPARATION LINE (IMAGINARY PROPERTY LINE) <br />1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO <br />DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED <br />APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND <br />DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED <br />DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE <br />FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP <br />SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR <br />STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, <br />ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER <br />PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING <br />AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE- <br />WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS- <br />BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS <br />REQUIRED. <br />2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS <br />PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL <br />PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER <br />GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES <br />SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER <br />OR STORM DRAIN SYSTEM. <br />3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND <br />UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION <br />FACILITIES (POWER POLES, PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, <br />VALVES, METERS, PPURTENANCES, ETC.) OR TO THE LOCATION OF THE <br />HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY <br />POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS <br />AND/OR ADDITIONAL EXPENSES. <br />4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION <br />PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING <br />INSPECTOR PRIOR TO INSTALLATION. <br />5. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL <br />TIMES. <br />6. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE <br />DURATION OF THE PROJECT. <br />7. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN <br />REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. <br />1 <br />1. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE <br />FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE <br />RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE <br />CONTAINING THE FUEL GAS PIPING. <br />2. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW <br />CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED <br />FOR LOW WATER CONSUMPTION. <br />3. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND <br />APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. <br />4. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR <br />STREET IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE <br />PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO <br />DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. <br />5. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE <br />AND LOCAL CODES AND AMENDMENTS. <br />6. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES <br />WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR <br />STREET RIGHT-OF-WAY. <br />7. WATER HEATER MUST BE STRAPPED TO WALL. <br />8. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />9. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO <br />CONFIRM THAT THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN <br />5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, <br />THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL <br />ENGINEER TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. <br />10. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE <br />STANDARD LISTED IN CH.6 & CH.7 CRC <br />11. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. <br />12. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR <br />ELECTRICAL, CABLE TV. AND TELEPHONE <br />13. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH <br />CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED <br />14. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED <br />RECEPTACLE OUTLETS. <br />15. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS <br />WITHOUT OPENABLE WINDOW. <br />16. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC <br />OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC <br />17. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE <br />WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. <br />18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A <br />NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE <br />AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM <br />AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. <br />19. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT <br />DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE <br />EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE <br />BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. <br />ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR <br />PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER <br />OF RECORD. <br />20. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER <br />SCALE. <br />21. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE <br />OWNER AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, <br />IMMEDIATELY. <br />22. VERIFY WITH AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT <br />ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT <br />ISSUANCE. <br />23. WHEN SOLAR PANEL IS REQUIRED, SOLAR PLANS SHALL BE REVIEWED AND <br />APPROVED BY BUILDING DIVISION PRIOR TO ROOF SHEATHING INSPECTION. <br />24. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TO ACCOMMODATE A <br />DEDICATED 208/240-VOLT BRANCH CIRCUIT (40 AMP) COMPLIANCE WITH <br />SECTION 4.106.4.1 <br />25. THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE <br />OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV <br />CHARGING AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE <br />PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". <br />1 <br />THE PROPOSED PROJECT IS A NEW 791 SF DETACHED ADU, ATTACHED 302 SF 1-CAR GARAGE AND <br />CONSIST OF: <br />• 2 BEDROOMS, 2 BATHROOMS. <br />• KITCHEN, DINING, LIVING ROOM. <br />• 52 SF PATIO, 19 SF LANDING. <br />• NEW CENTRAL AC, NEW HEATPUMP WATER HEATER, NEW AIR HANDLERS. <br />• DUAL-GANG ELEC PANEL METER AND SUB-PANEL. <br />THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE . <br />SANTA ANA, AMENDMENTS AND MUNICIPAL CODE. <br />LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92701 1 <br />THE DESIGN OF THE ACCESSORY DWELLING UNIT SHALL BE ARCHITECTURALLY <br />COMPATIBLE WITH THE MAIN DWELLING UNIT, WITH ALL DESIGN. THE DESIGN, ROOF <br />PITCH, DEPTH OF EAVE, COLOR, MATERIAL AND TEXTURE OF THE ROOF SHALL BE <br />SUBSTANTIALLY THE SAME AS THE MAIN DWELLING UNIT. <br />PL 56.58' <br />PL <br /> <br />1 <br />0 <br />0 <br />. <br />0 <br />2 <br />' <br />PL <br /> <br />6 <br />4 <br />. <br />8 <br />7 <br />' <br />PL <br />1 <br />4 <br />.28' <br />PL <br />35. <br />4 <br />6 <br />' <br />PL 42.84' <br />(E) <br />42'-11 1/2" <br />(E <br />) <br /> <br />25 <br />' <br />- <br />9 <br />" <br /> <br />(E <br />) <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />22 <br />' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />(E <br />) <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />4' <br />- <br />1 <br />0 <br />" <br />(E) <br />32'-4" <br />27 <br />' <br />- <br />0 <br />" <br />(E <br />) <br /> <br />27 <br />' <br />- <br />0 <br />" <br /> <br />(E) S <br />E <br />T <br />B <br />A <br />C <br />K <br />5'-8 <br /> 1/2" <br />(E) <br />13'-8" <br />(E) <br />5'-0" <br />(E <br />) <br />3' <br />- <br />0 <br />" <br />(E) <br />23'-8" <br />(E) <br />21'-0" <br />(E <br />) <br /> <br />19 <br />' <br />- <br />1 <br />" <br />(E) <br />20'-1" <br />(E) 2- CAR GARAGE <br /> 420 SF <br />SINGLE FAMILY RESIDENCE <br />1044 SF <br />901 E MYRTLE ST, SANTA ANA, CA 92701 <br />(E) PROCH <br />STREET CURB & <br />GUTTER <br />CENTERLINE OF <br />STREET <br />CENTERLINE OF <br />STREET <br />(E <br />) <br /> <br />22 <br />' <br />- <br />6 <br />" <br /> <br />(E) POWER POLE <br />1 <br />2 <br />2 <br />2 <br />8 <br />4 4 <br />4 <br />8 <br />9 <br />9 <br />9 <br />9 <br />3 <br />15 <br />16 <br />7 <br />5 <br />2 <br />9 <br />9 <br />9 <br />9 <br />4 <br />21 <br />2 2 <br />9 <br />(E <br />) <br /> <br />1' <br />- <br />0 <br />" <br />(E) <br />18'-8" <br />(E) <br />4'-9 1/2" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E) <br />1'-0" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E) SET BACK <br />5'-9 1/2" <br />(E <br />) <br />3' <br />- <br />1 <br />0 <br />" <br />(E) <br />31'-4" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E) <br />19'-3 1/2" <br />(E <br />) <br />22 <br />' <br />- <br />9 <br />" <br />(E <br />) <br /> <br />4' <br />- <br />0 <br />" <br /> <br />(E <br />) <br /> <br />3' <br />- <br />0 <br />" <br /> <br />(E <br />) <br />6" <br /> <br />TO <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />30 <br />' <br />- <br />0 <br />" <br />(E <br />) <br /> <br />20 <br />' <br />- <br />0 <br />" <br /> <br />E MYRTLE ST <br />S <br />S <br />T <br />A <br />N <br />D <br />A <br />R <br />D <br /> <br />A <br />V <br />E <br />ALLEY <br />PL 56.58' <br />PL <br /> <br />1 <br />0 <br />0 <br />. <br />0 <br />2 <br />' <br />PL <br /> <br />64 <br />. <br />87 <br />' <br />PL <br />14.28' <br />PL <br />3 <br />5 <br />. <br />46' <br />PL 42.84' <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E <br />) <br /> <br />1' <br />- <br />0 <br />" <br /> <br />(E) <br />1'-0" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />(E) <br />1'-0" <br />(E <br />) <br /> <br />T <br />O <br /> <br />C <br />E <br />NT <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br /> <br />30 <br />' <br />- <br />0 <br />" <br /> <br />(E) <br />42'-11 1/2" <br />(E <br />) <br /> <br />25 <br />' <br />- <br />9 <br />" <br /> <br />(E <br />) <br /> <br />F <br />R <br />O <br />N <br />T <br /> S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />22 <br />' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />(E <br />) <br /> <br />S <br />E <br />T <br />B <br />A <br />CK <br /> <br />4' <br />- <br />1 <br />0 <br />" <br /> <br />(E) 2- CAR GARAGE <br /> 420 SF <br />SINGLE FAMILY RESIDENCE <br />1044 SF <br />901 E MYRTLE ST, SANTA ANA, CA 92701 <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />TO <br /> <br />C <br />E <br />N <br />T <br />E <br />RL <br />I <br />N <br />E <br />10 <br />' <br />- <br />0 <br />" <br />(E) <br /> SE <br />TBA <br />C <br />K <br />5'-8 1/ <br />2" <br />(E) <br />13'-8" <br />(E) TOCENTER LINE <br />30'-0" <br />(E) PROCH <br />STREET CURB & <br />GUTTER <br />CENTERLINE OF <br />STREET <br />CENTERLINE OF <br />STREET <br />(E <br />) <br />4' <br />- <br />0 <br />" <br />(E <br />) <br /> <br />3' <br />- <br />0 <br />" <br /> <br />(E <br />) <br />6" <br />(E <br />) <br /> <br />22 <br />' <br />- <br />6 <br />" <br /> <br />(E) <br />5'-0" <br />(E <br />) <br />3' <br />- <br />0 <br />" <br />(E) <br />19'-3 1/2" <br />(E) <br />23'-8" <br />(E) <br />4'-0" <br />(E) <br />3'-0" <br />(E) <br />6" <br />(E) POWER POLE <br />(E <br />) <br />19 <br />' <br />- <br />1 <br />" <br />(E) <br />20'-1" <br />1 <br />2 <br />2 <br />2 <br />8 <br />44 <br />4 <br />8 <br />9 <br />9 <br />9 <br />9 <br />3 <br />15 <br />16 <br />7 <br />5 <br />2 <br />9 <br />9 <br />9 <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />DI <br />S <br />T <br />A <br />N <br />C <br />E <br /> <br />6' <br />- <br />0 <br />" <br /> <br />F. <br />S <br />. <br />D <br />3' <br />- <br />0 <br />" <br />F. <br />S <br />. <br />D <br /> <br />3' <br />- <br />0 <br />" <br /> <br />DISTANCE <br />5'-1" <br />(N) ADU 1-CAR <br />GARAGE <br />302 SF <br />20 <br />20 <br />20 <br />4 <br />F.S.L <br />17'-4 1/2"9'-10 1/2" <br />10'-2" <br />(E) SETBACK <br />18'-0" <br />(N) DETACHED ADU - UNIT 2 <br />791 SF <br />901 E MYRTLE ST, SANTA ANA, CA 92701 <br />(E) SETBACK <br />5'-9 1/2" <br />21 <br />22 <br />22 <br />F. <br />S <br />. <br />D <br />3' <br />- <br />0 <br />" <br />F. <br />S <br />. <br />D <br /> <br />3' <br />- <br />0 <br />" <br /> <br />22 <br />2 <br />AD.20 <br />2 <br />AD.20 <br />14 <br />(E) <br />1'-0" <br />(E) <br />18'-0" <br />(E) <br />4'-9 1/2" <br />9 <br />9 <br />23 <br />9 <br />3' <br />- <br />1 <br />0 <br />" <br />51'-7" <br />41 <br />' <br />- <br />0 <br />" <br /> <br />22 <br />9 <br />2 <br />AD.20 <br />19 <br />19 <br />17 <br />13 <br />MIN. <br />2'-0" <br />18 <br />23 <br />35 <br />' <br />- <br />1 <br />0 <br />" <br />10 <br />10 <br />11 <br />12 <br />(E <br />) <br />1' <br />- <br />0 <br />" <br />DI <br />S <br />T <br />A <br />N <br />C <br />E <br />6' <br />- <br />0 <br />" <br />(N) WALKWAY <br />CLR <br />12'-0"9 <br />E MYRTLE ST <br />S <br />S <br />T <br />A <br />N <br />D <br />A <br />R <br />D <br /> <br />A <br />V <br />E <br />4' <br />- <br />0 <br />" <br />ADU SETBACK <br />5'-0" <br />16'-4 1/2"1'-0" <br />1'-0" 4'-0" <br />ALLEY <br />21 <br />' <br />- <br />5 <br />" <br />20 <br />5 <br />AD.20 <br />1 <br />9 <br />E <br />JURISDICTION HAVING AUTHORITY: CITY OF SANTA ANA, CA 92701 <br />LEGAL DESCRIPTION: N TRACT 2482 BLK, LOT 72 <br />ASSESSORS PARCEL NO. APN: 404-011-11 <br />IN FLOOD ZONE FEMA SHFA'S: FLOOD ZONE X <br />CONSTRUCTION TYPE: V-B <br />ZONING: R1 (SINGLE FAMILY RESIDENTIAL) <br />OCCUPANCY GROUP: R3/U <br />SPRINKLERS: <br />EXISTING: NO <br />ADU: NO <br />(E) MAINHOUSE MAX HEIGHT: 15 FT <br />ADU MAX. HEIGHT: 14 FT <br />(E) REQUIRED SETBACKS: <br />FRONT: 4 FT <br />SIDE: 4 FT <br />REAR: 4 FT <br />DISTANCE TO (E) STRUCT: 6 FT <br />LOT SIZE: 6,554 SF <br />EXISTING: <br />(E) MAIN HOUSE LIVING AREA: 1,044 SF <br />(E) GARAGE: 420 SF <br />EXISTING TOTAL: 1,464 SF <br />NEW CONSTRUCTION <br />(N) DETACHED ADU: 791 SF <br />(N) GARAGE: 302 SF <br />(N) COVER PORCH: 52 SF <br />(N) LANDING: 19 SF <br />NEW TOTAL: 1,164 SF <br />MAXIMUM LOT COVERAGE: 35% <br />OVERALL LOT COVERAGE: (1,164 SF + 1,464 SF) / 6,554 SF = 40,1% <br />LOT COVERAGE AND USE INTENSITY MAXIMUM ESTABLISHED IN ZONING <br />DISTRICT MAY BE EXCEEDED TO PERMIT AN ADU UP TO EIGHT HUNDRED <br />(800) SQUARE FEET IN SIZE <br />PARKING REQUIREMENT <br />NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS <br />ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN <br />ACCORDANCE WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN <br />ACCESSORY DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: <br />THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING <br />DISTANCE OF PUBLIC TRANSIT. <br />TOTAL PARKING REQUIRED <br />(E) MAIN HOUSE: 2 STALLS <br />(N) ADU 1 STALL (SEE EXCEPTION ABV.) <br />TOTAL: 3 STALLS <br />PROJECT LOCATION <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATE DELTA <br />NEW DETACHED ADU 2 <br />BEDS, 2BATHS, <br />LIVING , KITCHEN, <br />DINING , GARAGE-1 <br />CAR <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />28/11/2023 PLANNING CORRECTIONS <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: <br />LOANPHAM8888@YAHOO.COM <br />1 02/22/2024 1ST PLAN CHECK <br />03/11/2024 2ND PLAN CHECK2 <br />A.00 <br />SITE PLAN <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(E <br />) <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />SHEET INDEX <br />SITE PLAN KEYNOTES <br />GENERAL NOTES PROJECT DATA <br />ARCHITECTURAL <br />A.04 EXISTING - FLOOR PLAN <br />A.05 PROPOSED ADU FLOOR & ROOF PLAN <br />A.06 PROPOSED ADU SECTIONS & ELEVATIONS <br />AD.10 ARCHITECTURAL DETAILS <br />AD.20 ARCHITECTURAL DETAILS <br />D.01 DRAINAGE PLAN <br />T24.1 TITLE 24 <br />T24.2 TITLE 24 (CONT.) <br />T24.3 TITLE 24 (CONT.) <br />STRUCTURAL <br />S-0.10 GENERAL NOTES & REQUIREMENTS <br />S-0.11 GENERAL NOTES & REQUIREMENTS <br />S-1.0 FOUNDATION PLAN <br />S-2.0 FRAMING PLAN <br />SD1.0 FOUNDATION DETAILS <br />SD2.0 STRUCTURAL DETAILS <br />WSWH1 STRONG WALL WSWH ANCHORAGE DETAIL <br />WSWH 1.1 STRONG WALL WSWH ANCHORAGE ALTERNATE DETAIL <br />WSWH2 STRONG WALL WSWH FRAMING DETAIL <br />APPLICABLE CODE <br />SPECIAL NOTES <br />1" = 10'-0" 1EXISTING SITE PLAN 1" = 10'-0" 2PROPOSED SITE PLAN <br />SYMBOL LEGEND CONSTRUCTION NOTES <br />VINCITY MAP <br />DEFERRED SUBMITTALS <br />SCOPE OF WORK <br />2.41 KW PER T24 PV SYSTEM WILL BE UNDER A SEPARATE PERMIT FOR ADU <br />THE MAIN ELECTRICAL SERVICE PANEL RATING OF 225 AMPS. THE MAIN SERVICE PANEL SHALL HAVE A <br />MINIMUM BURSAR A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. <br />THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER <br />LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY MARKED AS "FOR FUTURE SOLAR <br />ELECTRIC". <br />SOLAR PV SYSTEM MUST BE APPROVED REQ BUILDING DIVISION PRIOR ROOF SHEATHING INSPECTION. <br />2.15 kW PHOTOVOLTAIC SYSTEM WILL BE SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE ISSUED <br />PRIOR TO BUILDING FRAME INSPECTION REQUEST <br />(E) BLOCK WALL TO BE DEMOLISHED <br />NOTE: <br />THE APPLICANT / PROPERTY OWNER SHALL BE RESPONSIBLE <br />FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND / <br />OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. <br />1 <br />1 <br />1 <br />2 <br />A.01 CAL GREEN CODE <br />A.02 CAL GREEN CODE <br />A.03 GENERAL DETAILS <br />A.00 SITE PLAN <br />A.08 ROOM FINISH & DOOR/WINDOW SCHEDULE & INTERIOR DETAILS <br />A.07 PROPOSED ADU ELECTRICAL PLAN <br />S-0.20 TYPICAL DETAILS <br />S-0.12 SOIL REPORT <br />S-0.13 SOIL REPORT <br />S-0.14 SOIL REPORT <br /> & SOIL REPORT <br />BLDG# 101118160 <br />APPROVALS <br />PLNG - ASevilla <br />BLDG - GHuang <br />POLICE - BMartin <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024