My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
901 E Myrtle St Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Myrtle St
>
901 E Myrtle St Unit# 2
>
901 E Myrtle St Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:39 PM
Creation date
6/6/2025 1:22:10 PM
Metadata
Fields
Template:
Plan
Permit Number
101118160
Full Address
901 E Myrtle St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. WINDOW MANUFACTURER AND INSTALLER SHALL INSURE THAT ALL WINDOWS <br />MEET OR EXCEED ALL EGRESS REQUIREMENTS OF CRC R310 & R312 <br />2. ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE INSTALLED PER <br />AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION AAMA 2400=02 <br />RECOMMENDATIONS "STANDARD PRACTICE FOR INSTALLATION OF WINDOWS <br />WITH INTEGRAL MOUNTING FLANGES IN STUD FRAME CONSTRUCTION". <br />3. INSTALL AN ISOLATION MEMBRANE BELOW THE THRESHOLD OF ALL SLIDING <br />GLASS DOORS THAT REST ON A CONCRETE SLAB. <br />4. ALL SEALANT SHALL BE OF HIGH QUALITY AND REVIEWED OFR COMPATIBILITY <br />WITH ASPHALTIC MEMBRANES AND FLASHING MATERIAL. <br />44 <br />" <br /> <br />M <br />A <br />X <br />I <br />M <br />U <br />M <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />20" MINNIMUM <br />F.F. > 72" ABV. FINISH GRADE. <br />24 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br /> <br />@ <br />44 <br />" <br /> <br />M <br />A <br />X <br />I <br />M <br />U <br />M <br />20" MINNIMUM <br />F.F. > 72" ABV. FINISH GRADE. <br />24 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br /> <br />@ <br />5.7 S.F MINIMUM <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />5. <br />7 <br /> <br />S <br />. <br />F <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />2. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />3. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES <br />ABOVE THE FLOOR. <br />EMERGENCY EGRESS <br />WINDOW AND DOOR NOTE <br />AGING IN PLACE <br />R327.1.3 INTERIOR DOORS <br />EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN 32 <br />INCHES (812.8 MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A TWOOR THREE-STORY SINGLE <br />FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />R327.1.4 DOORBELL BUTTONS <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE <br />DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED <br />FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE <br />EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. <br />R327.1.1 REINFORCEMENT FOR GRAB BARS <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON <br />THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 39 1/4 INCHES (997 MM) <br />ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL <br />REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. <br />EXCEPTIONS: <br />1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR <br />INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PREFABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORYINSTALLED <br />GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION <br />OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED <br />REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS: <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING <br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES <br />(1219.2 MM) MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH <br />FLOOR. <br />EXCEPTIONS: <br />1. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />2. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE <br />ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR <br />AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW,IS <br />LESS THAN 15 INCHES (381 MM) <br />1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE. <br />2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT SCREEN-METAL. DOORS & <br />WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR A1342. <br />3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONALS <br />FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE W ITH THE ENERGY CALCULATIONS. <br />4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. <br />5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, LASER-ETCHED, OR <br />EMBOSSED PER CRC 2406.3. <br />6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD. <br />7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE) <br />8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR <br />9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE AVAILABLE FOR USE BY <br />THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY. MOVEABLE PANELS SHALL NOT BE EASILY REMOVED <br />FROM THE FRAME. <br />10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA <br />IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY BE POVIDED BY A DOOR VIEW, A VIEW PORT, <br />WINDOW, OR OTHER OPENING. <br />11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF 1 INCH AND AN <br />EMBEDMENT OF NOT LESS THAN 5/8 INCH. <br />12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE EQUIPPED WITH A DEAD <br />BOLT. <br />13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE WHEN THE <br />DOOR IS CLOSED. <br />14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK. <br />15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4" THICK. <br />16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR SHALL BE FULLY <br />TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS. <br />17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/W INDOW ROUGH OPENING DIMENSIONS WITH THE <br />MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION <br />18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. (R309.4) <br />19. EMERGENCY EGRESS: <br />A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />B. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. <br />ATTIC AIR HANDLER <br />20' MAX. <br />30" MIN. <br />MIN. 30X30" WORKING <br />PLATFORM SECURED IN <br />PLACE <br />22x30" MIN. <br />ATTIC ACCESS <br />MIN. 24" WIDE SOLID <br />FLOORING FROM ACCESS <br />OPENING TO FURNACE <br />WORKING PLATFORM <br />LIGHT SWITCH <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />ELECTRIC OUTLET AND <br />LIGHT FIXTURE <br />AIR HANDLER DISCONNECT <br />AND ELECTRICAL OUT LET <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU 2 <br />BEDS, 2BATHS, <br />LIVING , KITCHEN, <br />DINING , GARAGE-1 <br />CAR <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />1 28/11/2023 PLANNING CORRECTIONS <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: <br />LOANPHAM8888@YAHOO.COM <br />A.03 <br />GENERAL DETAILS <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(E <br />) <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DOOR/ WINDOW NOTES <br />ATTIC AIR HANDLER REQUIREMENTS <br />WATER HEATER REQUIREMENTS <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024
The URL can be used to link to this page
Your browser does not support the video tag.