AT <br />T <br />I <br />C <br />HP <br />W/H <br />RE <br />F <br />. <br />DW <br />DW <br />AT <br />T <br />I <br />C HP <br />1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO CASEWORK FABRICATION <br />INSTALLATION. <br />2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. <br />INSTALL MATCHING BASE BD. <br />3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. <br />4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NON- <br />ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. <br />5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. <br />6. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. <br />7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD WIRED WITH BATTERY BACK-UP AND <br />LOCATED (1) IN EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE AUDIBLE <br />IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. <br />INSTALL AND LOCATE PER MFGR. LISTED REQUIREMENTS. <br />8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING ROOMS PER CHAPTER 3 CRC. <br />9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO THE EXTERIOR OF THE BUILDING <br />10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. <br />11. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. <br />12. PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE SHEATHING AT EXTERIOR WALLS. <br />13. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3½ INCHES SHALL BE <br />PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR <br />2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) <br />14. ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID WALKWAY AT LEAST 24" WIDE. A SWITCH <br />CONTROL IS ALSO REQUIRED (CMC 304.4.1) <br />15. DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET <br />(4267 MM), INCLUDING TWO 90 DEGREE (1.57 RAD) ELBOWS. A LENGTH OF 2 FEET (610 MM) SHALL BE DEDUCTED FOR EACH 90 DEGREE (1.57 <br />RAD) ELBOW IN EXCESS OF TWO. <br />16. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED <br />FOR LOW WATER CONSUMPTION. <br />17. WATER HEATER MUST BE STRAPPED TO WALL. <br />18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR <br />SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR <br />LEVEL. <br />19. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 <br />CRC <br />20. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. <br />21. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: <br />(BEES 150.0(N)1A-D) <br />A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. <br />B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. <br />C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. <br /> D. A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM. <br />22. ADU FINISH FLOOR ELEVATION IS NOT NOT LOWER THAN THE FINISH FLOOR OF THE MAIN HOUSE AND HIGHER 1' MINIMUM THAN BASE FLOOD <br />ELEVATION. <br />EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% <br />CE OR 250 CFM (EXHAUST THROUGH ROOF) <br />(N) 2X4 INTERIOR WALL <br />(N) 2X4 EXTERIOR WALL / INFILL <br />WITH INSULATION PER T-24 <br />1-HOUR FIRE RATED WALL <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING <br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ <br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />IAQ FAN: ( MIN 46 CFM PER T-24 ) <br />PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, <br />MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD <br />CARBON MONOXIDE DETECTOR ALARM <br />HARDWIRED w/ BATTERY BACK UP <br />CD <br />22X30 ATTIC ACCESS <br />HEATPUMP + AIR HANDLER <br />HEATPUMP UNIT ON PAD 3" MIN. <br />LAUNDRY DRYER EXHAUST <br />CEILING AIR DIFFUSER <br />ELECTRICAL PANEL/METER PER KEYNOTE <br />CONSUMER TANK WITH/ HEAT PUMP <br />DOOR TYPE SEE A.08 FOR SCHEDULE <br />WINDOW TYPE SEE A.08 FOR SCHEDULE <br />KEY NOTE <br />FLOOR DEPRESSION1.5'' <br />XX <br />XX <br />XX <br />WHOLE HOUSE FAN: 1186.5 CFM PER T-24 <br />E ELECTRICAL VEHICLE CHARGING <br />STATION LOCATION. 208/240-VOLT <br />BRANCH CIRCUIT (40 AMP) <br />1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />7 <br />9 EXHAUST FAN FOR BATHROOM SHALL BE MINIMUM 50 CFM <br />AND CONTAIN HUMIDISTAT (EXHAUST THROUGH ROOF). <br />10 EXHAUST FAN ABOVE KITCHEN GAS RANGE SHALL BE 85% CE OR 250 <br />CFM (EXHAUST THROUGH ROOF) <br />11 <br />8 <br />(N) DUAL-GANG ELECT. METER BOX <br />(N) ELECTRICAL SUB-PANEL 225 AMPS <br />(N) LANDING. 1 1/2" BELOW THRESHOLD. MINIMUM 36" IN <br />DEPTH.MIN. 2% SLOPE AWAY FROM BUILDING. <br />(N) 22X30 ATTIC ACCESS <br />2'' SHOWER CURB <br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK <br />DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 <br />FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH <br />EXTERIOR WALL/ROOF) <br />6 <br />(N) HEAT PUMP UNIT ON 3" THIK. CONCRETE PAD <br />(N) 6X6 POST <br />TEMPERED GLASS <br />12 (N) CONSUMER TANK WITH/ HEAT PUMP, DETAIL ON SHEET A.03 <br />13 APPROVED PRE-FABRICATED SHOWER ENCLOSURES WALL PANELS <br />WITH FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS. SMOOTH, <br />NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES <br />ABOVE THE DRAIN INLET <br />14 FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR <br />15 2X8 BACKING FOR FUTURE GRAB BAR INSTALLATION <br />16 32'' MIN. CLR. INTERIOR DOOR SEE NOTE ON ''AGING-IN-PLACE'' <br />17 <br />18 OBSCURED,TEMPERED GLASS <br />19 1HR FIRE RATED WALL, UPNPROTECTED OPENING MAX <br />25% WALL AREA, SEE CALCULATION ON ELEV. 01/A.06,02/A.06 <br />20 8'' GARAGE CURB, SEE STRUCTURAL DWG <br />21 DOOR BETWEEN GARAGE AND LIVING AREA SHALL BE 20 MIN. RATED 1-3/8" <br />SOLID CORE WITH CLOSER AND LATCHING HARDWARE, SMOKE SEAL @ <br />JAMB, HEAD @ METAL THRESHOLD <br />5/8" TYPE "X" GYPSUM BOARD ALL WALLS, CEILINGS, BEAMS, POSTS <br />AND COLUMNS, SMOOTH FINISH TYPICAL AT GARAGE <br />1.ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE <br />UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING <br />OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST <br />DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE <br />PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH <br />OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM <br />TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. <br />2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE <br />NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN <br />CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE <br />CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS <br />LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE <br />THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF <br />TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF <br />FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET <br />BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. <br />3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF <br />A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. <br />4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF <br />VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF <br />VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. <br />5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) <br />AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE <br />UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF <br />FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: <br />1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. <br />2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE <br />UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. <br />3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR <br />SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. <br />4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR <br />RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE <br />UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) <br />5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION <br />DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD <br />SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS <br />INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER <br />WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); <br />5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE <br />UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. <br />5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY <br />BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE <br />INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. <br />5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE <br />APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION <br />CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE <br />INSULATION. <br />5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR0IMPERMEABLE INSULATION LAYER, IT SHALL <br />BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. <br />ATTIC AREA: 800 SF <br />USE BALANCE METHOD : 1/300 <br />NET VENT AREA REQUIRE : 800/300 x 144 SQ.IN. = 384 SQ.IN <br />FOR WHOLE HOUSE VENT: 1186.5 CFM-227 SQ.IN VENT NFA IS REQUIRED ( 144 SQFT PER 750 <br />CFM) <br />TOTAL VENT AREA REQUIRED: 611 SQ.IN <br />NOTE: MAX 50% ON UPPER ROOF AREA <br />LOW: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) = 216 SQ.IN (1/3 LOW AREA OF ROOF) <br />HIGHT: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT)= 216 SQ.IN (1/3 HEIGHT AREA OF ROOF) <br />+ 10 FT RIGDE VENT (18 SQ.IN/FOOT)= 180 SQ.IN <br />TOTAL = 612 SQ.IN <br />4'-9 1/2"4'-9 1/2" <br />9'-7 1/2" <br />2' <br />- <br />0 <br />" <br />3'-1" <br />11 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />5 <br />" <br />20 <br />' <br />- <br />1 <br />0 <br />" <br />15'-1 1/2"8'-10"5'-4 1/2" <br />5' <br />- <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />7 <br />" <br />3'-10"8'-4"5'-4 1/2" <br />B <br />A.06 <br />B <br />A.06 <br />GARAGE <br />15"15" <br />17 <br />" <br />17 <br />" <br />21'-1 1/2"12'-8" <br />5' <br />- <br />8 <br />" <br />17 <br />' <br />- <br />1 <br />1 <br />" <br />8'-0" <br />5' <br />- <br />0 <br />" <br />5'-0" <br />14 <br />' <br />- <br />9 <br />" <br />51'-4" <br />A.06 <br />2 <br />A. <br />0 <br />6 <br />3 <br />A.06 <br />1 <br />A. <br />0 <br />6 <br />4 8' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />11'-9 1/2" <br />3' <br />- <br />6 <br />" <br />5' <br />- <br />3 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />8'-11 1/2" <br />5'-0" <br />A <br />A.06 <br />A <br />A.06 <br />SD <br />CDSD <br />CDSD <br />SD <br />30" <br />3'-0" <br />6' <br />- <br />0 <br />" <br />1. <br />5 <br />' <br />' <br />1.5'' <br />1 2 <br />3 <br />5 <br />3 <br />3 <br />3 <br />4 <br />6 <br />5' <br />- <br />0 <br />" <br />20'-9" <br />14 <br />' <br />- <br />1 <br />" <br />A <br />B <br />B C <br />30'' CLR <br />30'' CLR 12 <br />6 <br />11 <br />3 <br />3 11 <br />16 <br />9 <br />9 <br />7 <br />10 <br />13 <br />13 <br />11 5 <br />5 <br />15 <br />3'-5 1/2" <br />36'' CLR. <br />FRONT OF <br />PANEL <br />15 14 <br />14 <br />BEDROOM#1 <br />10FT CL'G <br />KITCHEN <br />10FT CL'G <br />LIVING <br />10FT CL'G <br />BEDROOM#2 <br />10FT CL'G <br />W.I.C <br />10FT CL'G <br />BATH#1 <br />10FT CL'G <br />BATH#2 <br />10FT CL'G <br />PORCH <br />CLOSET <br />4' <br />- <br />6 <br /> <br />1 <br />/ <br />2 <br />" <br />EE&RO <br />EE&RO <br />18 <br />18 <br />19 <br />19 <br />2 <br />AD.20 <br />2 <br />AD.20 <br />88 <br />21 <br />NOTE: NO INSULATION <br />NO HEATING <br />NO COOLING <br />20 <br />17 <br />2 <br />AD.20 <br />6 <br />AD.20 <br />2'' <br />4 <br />11 <br />2020 <br />10FT CL'G <br />19 <br />COVER PORCH <br />12'-0" <br />6'-4"6'-0" <br />7 <br />1 <br />1 <br />1 <br />1 <br />21 <br />' <br />- <br />5 <br />" <br />EELECTRICAL VEHICLE <br />CHARGING STATION <br />LOCATION. 208/240-VOLT <br />BRANCH CIRCUIT (40 AMP) <br />1 <br />B <br />A.06 <br />B <br />A.06 <br />1'-0"1'-0" <br />6' <br />- <br />2 <br />" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br />B <br />E <br />L <br />O <br />W <br /> <br />WALL LINE BELOW <br />WALL LINE BELOW <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br /> <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br /> <br />WALL LINE BELOW <br />WALL LINE BELOW <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br /> <br />A.06 <br />2 <br />A. <br />0 <br />6 <br />3 <br />A.06 <br />1 <br />A. <br />0 <br />6 <br />4 <br />ROOF MATERIAL COVERING CLASS "A", TO MATCH WITH <br />EXISTING ROOF (EXISTING ROOFING MATERIAL TYPE: <br />ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537). <br />OVER PLYWOOD SHEATING OVER RADIANT BARRIER <br />OVER RAFTERS PWE STRUCTURAL DWGS. <br />3'-0" <br />4:12 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />A <br />A.06 <br />A <br />A.06 <br />O'HAGIN VENT 72 SQ.IN TYP. <br />O'HAGIN VENT 72 SQ.IN TYP. <br />3FT MIN. <br />3' <br />- <br />4 <br />" <br />3FT MIN. <br />3'-0" <br />O'HAGIN VENT 72 SQ.IN TYP. <br />FUTURE SOLAR ZONE <br />100 SF <br />FUTURE SOLAR ZONE <br />160 SF <br />POST BELOW POST BELOW <br />2 <br />AD.20 <br />2 <br />AD.20 <br />2 <br />AD.20 <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />11" <br />RIDGE VENT <br />10'-0" <br />EQEQEQ <br />EQ EQ EQ <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU 2 <br />BEDS, 2BATHS, <br />LIVING , KITCHEN, <br />DINING , GARAGE-1 <br />CAR <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />28/11/2023 PLANNING CORRECTIONS <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: <br />LOANPHAM8888@YAHOO.COM <br />1 02/22/2024 1ST PLAN CHECK <br />A.05 <br />PROPOSED ADU <br />FLOOR & ROOF <br />PLAN <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(E <br />) <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />1/4" = 1'-0"1PROPOSED ADU FLOOR PLAN <br />1/4" = 1'-0"2PROPOSED ADU ROOF PLAN <br />ROOF VENTILATION <br />NOTES: (CRC R806)PLAN KEYNOTES FLOOR PLAN NOTES <br />PLAN LEDGEND <br />ROOF VENTILATION <br />CALCULATION <br />ROOF PLAN <br />GENERAL NOTES <br />1. ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY <br />CERTAINTEED ICC-ESR# 3537. COLOR & PER THE INSTALLATION <br />OF ROOF COVERING SHALL BE IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />2. PROJECTIONS LESS THAN 5'-0" (HOUSE WITH NO SPRINKLER) <br />TO PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. <br />3. ROOF VENT : SEE ROOF VENTILATION CALCULATION. <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024