Laserfiche WebLink
RE <br />F <br />. <br />DW <br />DOOR/WINDOW REMARKS: <br />(1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE <br />FACE OF THE DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE. <br />(2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF <br />THE THRESHOLD TO THE BOTTOM OF THE STOP <br />(3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE <br />USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. <br />(4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20- <br />MIN FIRERATED DOOR AT OPENING TO DWELLING (CBC 715.4.3). <br />(5) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED <br />CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND <br />COMPLIANCE WITH THE ENERGY CALCULATIONS. <br />(6) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE <br />DETERMINED IN ACCORDANCE WITH ASTM E1300. <br />(7) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING <br />WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. <br />(8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, <br />CERAMIC-FIRED, ASER-ETCHED, OR EMBOSSED PER CRC 2406.3. <br />(9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS <br />(INCLUDING HOUSE TO GARAGE <br />(10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE <br />BATHROOM FINISH FLOOR <br />1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE. <br />2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT SCREEN-METAL. <br />DOORS & WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR A1342. <br />3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE <br />NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY CALCULATIONS. <br />4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH <br />ASTM E1300. <br />5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, LASER-ETCHED, OR <br />EMBOSSED PER CRC 2406.3. <br />6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD. <br />7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE) <br />8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR <br />9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE AVAILABLE <br />FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY. MOVEABLE PANELS SHALL NOT <br />BE EASILY REMOVED FROM THE FRAME. <br />10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW <br />OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY BE POVIDED BY A DOOR <br />VIEW, A VIEW PORT, WINDOW, OR OTHER OPENING. <br />11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF 1 INCH AND <br />AN EMBEDMENT OF NOT LESS THAN 5/8 INCH. <br />12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE EQUIPPED <br />WITH A DEAD BOLT. <br />13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE <br />WHEN THE DOOR IS CLOSED. <br />14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK. <br />15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4" THICK. <br />16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR SHALL BE FULLY <br />TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS. <br />17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/WINDOW ROUGH OPENING DIMENSIONS WITH <br />THE MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION <br />18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. <br />(R309.4) <br />19. EMERGENCY EGRESS: <br />A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />B. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. <br />FINISH NOTES: <br />(1) SEAL AND PAINTED W/ A COAT FLAT VINYL. <br />(2) UNDERCOAT AND FINISH W/SEMI-GLOSS ENAMEL <br />(3) KNOCKDOWN TEXTURE. <br />(4) TAPED DRYWALL JOINTS. <br />(5) SPRAYED SIMULATED ACOUSTIC PLASTER. <br />(6) ORANGE PEEL FINISH. <br />1.GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN <br /> AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. CRC R702.3.7.1 <br />2.ALL DOORS & WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE <br />3.CONCRETE SLAB AND UNDER FLOOR INSPECTIONS SHALL BE MADE AFTER IN-SLAB OR UNDER-FLOOR <br /> REINFORCING STEEL AND BUILDING SERVICE EQUIPMENT, CONDUITS, PIPING OR OTHER ANCILLARY <br /> BUILDING TRADE PRODUCTS OR EQUIPMENT ARE INSTALLED, BUT BEFORE ANY CONCRETE IS PLACED <br /> OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE SUBFLOOR R109.1.1.1 <br />4.ROUGH INSPECTION OF PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS SHALL BE MADE PRIOR <br /> TO COVERING OR CONCEALMENT, BEFORE FIXTURES OR APPLIANCES ARE SET OR INSTALLED, AND <br /> PRIOR TO FRAMING INSPECTION R109.1.2 <br />5.WATER PIPING MATERIAL WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC 604.1 OF THE <br /> CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEM SHALL BE <br /> INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC 604 OF THE CPC, INSTALLATION <br /> STANDARDS OF APPENDIX 1 OF THE CPC AND MANUFACTURERS RECOMMENDED INSTALLATION <br /> STANDARDS. CPVC WATER PIPING REQUIRESA CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC <br /> 604.4.1.1 OF THE CPC PRIOR TO PERMIT ISSUANCE. <br />BUILDING DEPT. NOTES: <br />8' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />5'-0" <br />17 <br />" <br />17 <br />" <br />2' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />2' <br />- <br />8 <br />" <br />8' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />A.081 <br />2 <br />30'' CLR <br />ADU F.F. <br />0' -8" <br />ADU TOP PL <br />10' -8" <br />1' <br />- <br />0 <br />" <br />2' <br />- <br />6 <br />" <br />1' <br />- <br />6 <br />" <br />3' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />CEILING SOFFIT <br />RANGE <br />RE <br />F <br />R <br />I <br />G <br />E <br />R <br />A <br />T <br />O <br />R <br />2' <br />- <br />0 <br />" <br />ADU F.F. <br />0' -8" <br />ADU TOP PL <br />10' -8" <br />WI <br />N <br />D <br />O <br />W <br />WI <br />N <br />D <br />O <br />W <br />CEILING SOFFIT <br />DISH <br />WASHER <br />3' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />2' <br />- <br />6 <br />" <br />1' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />RE <br />F <br />R <br />I <br />G <br />E <br />R <br />A <br />T <br />O <br />R <br />2'-1"1'-11"3'-6"1'-6" <br />8'-11" <br />1' <br />- <br />0 <br />" <br />ADU F.F. <br />0' -8" <br />MIRROR <br />3' <br />- <br />0 <br />" <br />6" <br />3' <br />- <br />0 <br />" <br />17"17" <br />6' <br />- <br />0 <br />" <br />2'-8"2'-10"2'-11 1/2" <br />8'-5 1/2" <br />WI <br />N <br />D <br />O <br />W <br />WI <br />N <br />D <br />O <br />W <br />SHOWER <br />ADU F.F. <br />0' -8" <br />5'-0" <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />3'-3"1'-9" <br />31 1/2" <br />6' <br />- <br />0 <br />" <br />SHOWER <br />2'-0"2'-0"3'-6"1'-6" <br />9'-0" <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />6 <br />" <br />2' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />2' <br />- <br />0 <br />" <br />13 <br />' <br />- <br />0 <br />" <br />A.06 <br />1 <br />2 <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU 2 <br />BEDS, 2BATHS, <br />LIVING , KITCHEN, <br />DINING , GARAGE-1 <br />CAR <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />1 28/11/2023 PLANNING CORRECTIONS <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: <br />LOANPHAM8888@YAHOO.COM <br />A.08 <br />ROOM FINISH & <br />DOOR/WINDOW <br />SCHEDULE & <br />INTERIOR DETAILS <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(E <br />) <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />NUMBE <br />R DOOR SIZE QTY DESCRIPTION U-FACTOR SHGC REMARKS <br />1 3' - 0" x 6' - 8" 1 EXTERIOR DOOR 1 PANEL/TEMPERED GLASS, VINYL FRAME, PAINTED FINISH 0.5 ENTRY DOOR (1) (2) (3) (9) <br />2 2' - 8" x 6' - 8" 1 SOLID CORE 1 PANEL, WOOD FRAME, PAINTED FINISH, 20 MINUTES MIN. FIRE <br />RATED DOOR <br />GARAGE TO HOUSE (4) <br />3 2' - 8" x 6' - 8" 4 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR <br />4 5' - 0" x 6' - 8" 1 SIDELITE SOLID CORE/TEMP. GLASS, VINYL FRAME, PAINTED FINISH EXTERIOR (1) (2) (3) (9) <br />5 3' - 0" x 6' - 8" 1 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR <br />6 5' - 0" x 6' - 8" 1 SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH INTERIOR <br />7 8' - 0" x 8' - 0" 1 METAL GARAGE DOOR <br />Grand total: 10 <br />DOOR SCHEDULEXWINDOW SCHEDULEX <br />ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARKS <br />A 1 5' - 0" x 4' - 0"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH <br />PER MFGR. <br />0.3 0.23 <br />B 2 2' - 6" x 2' - 0"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH <br />PER MFGR. <br />0.3 0.23 TEMP. OBSCURED @BATH (5), (10) <br />C 1 3' - 6" x 3' - 6"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH <br />PER MFGR. <br />0.3 0.23 <br />Grand total: 4 <br />DOOR/WINDOW NOTES <br />ROOM FINISH SCHEDULE <br />ROOM FLOOR BASE WALL MATERIAL WALL FIN. <br />CEILING <br />MATERIAL CEILING FIN. HEIGHT <br />BEDROOM#1 VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' <br />KITCHEN VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' <br />LIVING VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' <br />BEDROOM#2 VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' <br />W.I.C VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' <br />BATH#1 TILE WOOD 1/2'' GYP.BD. 2,3 1/2'' GYP.BD. 2,3 10'-0'' <br />BATH#2 TILE WOOD 1/2'' GYP.BD. 2,3 1/2'' GYP.BD. 2,3 10'-0'' <br />1/2" = 1'-0"1PROPOSED ADU BATH#2 PLAN <br />1/2" = 1'-0"2KITCHEN ELEVATION 1 1/2" = 1'-0"3KITCHEN ELEVATION 2 <br />1/2" = 1'-0"4PROPOSED BATH#2 SECTION1 1/2" = 1'-0"5PROPOSED BATH#2 SECTION 2 <br />1/2" = 1'-0"6PROPOSED ADU KITCHEN PLAN <br />1. STRING SHALL BE FABRICATED FROM EITHER HARD-DRAWN SPRING WIRE ( PER ASTM A227-21) OR OIL-TEMPERED WIRE ( PER ASTM A229-71) <br />2. MINIMUM DESIGN STANDARD SHALL BE 9000 CYCLES. <br />3. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED TESTING AGENCY. <br />4. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED DEVICE CAPABLE OF RESTRAINING THE SPRING OR ANY PART THERE OF IN THE EVENT IT <br />BREAKS. CONTAINMENT DEVICE SHALL BE TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY. <br />GARAGE DOOR STRINGS PER SEC. R309.5 <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024