Laserfiche WebLink
Service Voltage <br />240 <br />Section 220.82 Dwelling Unit <br />Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: <br />Amps Box A (VA) <br />15.63 3750 <br />Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: <br />Size in VA Size in VA <br />1500 <br />1500 <br />1500 <br />1000 <br />600 <br />1000 <br />1600 <br />5760 <br />3840 <br />Amps Box B (VA) <br />76.25 18300 <br />Total VA from Parts #1 and #2 combined:Box A + Box B =22050 <br />Total VA 22050 <br />First 10000 VA @ 100%10000 Remaining VA @ 40% <br />Remaining VA =12050 12050 x 40% =4820 VA <br />Adding First 10000 VA, if possible 10000 VA <br />Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:14820 VA <br />Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:61.75 Amps <br />Part #3 - Section 220.82(C) Heating and A/C loads: <br />*Combine the larger loads of either the Heating or the A/C loads togther <br />100% of all the Heating or A/C loads in VA:0 VA <br />100% of all the Heating or A/C loads in Amps:0.00 A <br />VA Volts Amps <br />Parts #1 & #2 14820 240 61.75 <br />Part #3 0 240 0.00 <br />Total VA for all Parts:14,820 <br />Totals Service/Feeder Load 61.75 <br />Dedicated circuit Dedicated circuit <br />Article 220 - Dedicated Backup Panel Calculation Job Code <br />5313 W Henderson Pl <br />Santa Ana, CA 92704 <br />109R-313VALA <br />Building Square Footage VA (watts)Amps <br />House 1250.00 3750 15.63 <br />Total for Part #1: <br />Laundry <br />Appliance Circuit - 1 <br />Appliance Circuit - 2 <br />Dishwasher <br />Disposal <br />Refrigerator <br />Microwave <br />Dryer <br />OTHER <br />Totals for Part #2: <br />Totals from all Parts <br />5313 W Henderson <br />Pl2/5/2025