My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2210 3%4 N Grand Ave Unit# WCC01 - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
2210 3/4 N Grand Ave Unit# WCC01
>
2210 3%4 N Grand Ave Unit# WCC01 - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 3:47:25 AM
Creation date
6/6/2025 1:22:17 PM
Metadata
Fields
Template:
Plan
Permit Number
101118404
101122299
Full Address
2210 3/4 N Grand Ave Unit# WCC01
Street Number
2210
Partial
3/4
Street Direction
N
Street Name
Grand
Street Suffix
Ave
Unit Number
WCC01
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Geotechnical Report of Subsurface Investigation <br />LA3642 SCE LAVETA SUB CS (LA23642A) <br />Job Number: 24125796 <br /> <br /> <br />April 29, 2024│4 <br />Fill Material Types <br />Soil Type USCS Classification Acceptable Parameters (for Structural Fill) <br />Imported Low- to <br />Moderate- Plasticity <br />Soil 2 <br />CL, ML, SC or SM All locations and elevations <br />Sand / Gravel with <br />greater than 12% <br />fines <br />GW/GP, SW/SP <br />Crushed stone base course may be used for the access <br />roadway or beneath shallow foundations as a <br />replacement material for overexcavated soils. <br />Near-Surface <br />On-site soils 2 SM <br />On-site soils generally appear suitable for use as fill <br />when they contain at least 12% fines (clay and/or silt) <br />and are compacted at an appropriate moisture content. <br />1. Controlled, compacted fill should consist of approved materials that are free of organic matter and <br />debris. A sample of each material type should be submitted to the geotechnical engineer for evaluation. <br />2. Low- to moderate-plasticity cohesive soil or granular soil having at least 12% fines <br />Fill Compaction Requirements <br />Item Structural Fill General Fill <br />Maximum Lift <br />Thickness <br />8 inches or less in loose thickness when heavy, self- <br />propelled compaction equipment is used Same as Structural fill <br />Minimum <br />Compaction <br />Requirements 1, 2 <br />98% of max. below foundations and within 1 foot of <br />finished pavement subgrade <br />95% of max. above foundations, below floor slabs, <br />and more than 1 foot below finished pavement <br />subgrade <br />92% of max. <br />Water Content <br />Range 1 <br />Low plasticity cohesive: -2% to +3% of optimum <br />High plasticity cohesive: 0 to +4% of optimum <br />Granular: -3% to +3% of optimum <br />As required to achieve <br />min. compaction <br />requirements <br />1. Maximum density and optimum water content as determined by the standard Proctor test (ASTM D 698). <br />2. High plasticity cohesive fill should not be compacted to more than 100% of standard Proctor maximum <br />dry density. <br />2210 3%4 N Grand Ave Unit# <br />WCC01 - 1011184045/30/2024
The URL can be used to link to this page
Your browser does not support the video tag.