Laserfiche WebLink
By: J.R. <br />Date: 12/5/23 <br />Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7‐16) <br />Vult =130 mph Kzt =1.00 (sec 26.8.2)h = 15 ft <br />Exposure Category = C Kz = 0.85 (sec 26.10.1) <br />Roof Zone = 2 Kd =0.85 (sec 26.6) <br />Roof θ = 7‐27 deg Ke =1.00 (sec 26.9) <br />qh = 0.00256 Kz Kzt Kd Ke V2 qh =31.26 (eq. 26.10‐1) <br />GPp =‐2 uplift γE =1.5 (sec 29.4.4) <br />γa =0.76 (fig 29.4‐8) <br />γE =1.5 FIG 29.4‐7)γc =0.97 (fig 29.4‐7)hpt =0 <br />γa =0.76 (fig 29.4‐8)γp =0.9 (fig 29.4‐7)ω =0.00 deg (panel tilt) <br />GPp =‐2 uplift GCrm =1.4 uplift <br />p = qh (GPp) γE γa (eq 29.4‐7)p = qh (GCrn) γE γC γp (eq 29.4‐6) <br />p =‐71.6 p.s.f.p =57.3 p.s.f. <br />Check Anchorage to Existing Structur <br />0.6DL ‐ 0.6W controlling load combination (eq. 16‐15 for ASD) <br />DL = 2.8 p.s.f.dead load of panel (inlcuding rack system) <br />W = 71.6 p.s.f.wind load normal to face of panel <br />Arealag =12.3 sq. ft.area tributary to each anchor <br />SPanc =4.0 ft.spacing of anchors <br />Puplift = Arealag (0.6DL - 0.6W) =509.2 lbs total uplift on anchor <br />Material = DFL lumber anchor material <br />Dialag =5/16 in.diameter of screw <br />Penlag = 2.5 in.min. penetration to existing framing <br />W lag =266 lb/in.withdrawal load per in. of penetration per NDS Table 11.2A <br />CD = 1.6 load duration factor for wind per NDS Table 2.3.2 <br />Ct = 0.8 temperature factor per NDS Table 2.3.3 <br />Noscrews =2 number of screws in withdrawal <br />Pallow = Penlag (Wlag CD Ct) * Noscrews =1702.4 lbs total allowable withrawal on anchor <br />Puplift <br />Pallow <br />Anchorage =USE (2) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION <br />Wind Uplift Anchorage <br />Flush Mounted Panels ‐ ASCE Section  <br />29.4.4 (where applicable) <br />Flat Roof Panels ‐ ASCE Section 29.4.3  <br />(where applicable) <br />=0.30 < 1.00 Anchor is OK! <br />12/5/2023  9:03 AM <br />6 of 7 <br />©McPherson Engineering <br />2044 S Orange Ave - <br />101117921 & 201818526/13/2024