Laserfiche WebLink
EW <br />S <br />N <br />VANDERVOORT, DAVID <br />2307 NORTH TOWNER STREET <br />SANTA ANA, CA 92706 <br /> ÀPN/PARCEL NO: 00121406 <br />EXO ENERGY <br />1358 LA MIRADA DRIVE <br />SAN MARCOS, CA 92071 <br />(208) 351-4153 <br />MICHAEL ESPINOZA <br />CSLB: 1063308 <br />ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA <br />UM MSPBI GENINVINVCOM <br />AC <br />ACB <br />(E) CONCRETE DRIVEWAY <br />NO <br />R <br />T <br />H <br /> <br />T <br />O <br />W <br />N <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SWIMMING POOL (TYP.) <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />M <br />E <br />PROPERTY LINE <br />B <br />BB <br />GATE <br />GATE <br />UTILITY METER <br />MAIN SERVICE PANEL <br />AC DISCONNECT <br />DC DISCONNECT <br />AC COMBINER PANEL <br />INVERTER <br />BACKUP INTERFACE <br />BATTERY <br />PRODUCTION METER <br />SUBPANEL <br />UNCTION BOX <br />FIRE PATHWAY <br />PROPERTY LINE <br />ATTIC RUN CONDUIT <br />EXTERNAL CONDUIT <br />SATELLITE DISH <br />SITE PLAN LEGEND <br />MODULE SPEC AND ROOF INFO: <br />SCALE: 1/16À À 1À-0À <br />ROOF OBSTRUCTION (TYP.) <br />CHIMNEY <br />ROOF VENT (TYP.) <br />COM <br />PM <br />B <br />B <br />UM <br />MSP <br />INV <br />DC <br />BI <br />AC <br />SUB <br />PV MODULE TYPE - HANWHA .CELL BLK ML-G10À 400 (400W) <br />SOLAR AREA - 380.44 S FT <br />EXISTING SOLAR AREA - 635.04 S FT <br />ROOF AREA - 4610 S FT <br />ROOF COVERAGE -22.03 <br />UTILITY: <br />GAS METER GM <br />PV-2 <br />DATE:8/9/2024 <br />SITE PLAN-1 <br />swyssling@wysslingconsulting.com <br />(201) 874-3483 <br />DESIGN ENGINEER <br />SOLAR COMPANY/CLIENT <br />76 N. MEADOWBROOK DRIVE <br />ALPINE, UTAH 84004 <br />I SYSTEM CONTROLLER I <br />SITE PLAN NOTES: <br />1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. <br />2. PROVIDE RAIL SPLICES AS REUIRED BY MANUFACTURERÀS GUIDELINES. <br />3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. <br />4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, FURNACE OR <br />WATER HEATER VENTS <br />5. AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESSIBLE. TO <br />BE WITHIN 10À OF THE UTILITY METER <br />6. 3/4À OR GREATER CONDUIT RUN (7/8À ABOVE ROOF SURFACE) <br />7. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REUIRE THE <br />PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND <br />LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE <br />ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE <br />LIMBS, WIRES OR SIGNS. <br />LOAD CENTER LC <br />127À-11À <br />81À-11À <br />125À-4À <br />82À-5À <br />3À-9À <br />36À-11À <br />7À-1À <br />17À-11À <br />2307 N Towner St <br />8/23/2024