Laserfiche WebLink
ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA <br />VANDERVOORT, DAVID <br />2307 NORTH TOWNER STREET <br />SANTA ANA, CA 92706 <br /> PN/PARCEL NO: 00121406 <br />EXO ENERGY <br />1358 LA MIRADA DRIVE <br />SAN MARCOS, CA 92071 <br />(208) 351-4153 <br />MICHAEL ESPINOZA <br />CSLB: 1063308 <br />THE EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL OVERCURRENT DEVICES, <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, <br />SHALL NOT EXCEED AMPACITY OF BUSBAR <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SECOND SOURCE IS PHTOVOLTAIC SYSTEM <br />MAXIMUM AC OPERATING CURRENT: <br />PHOTOVOLTAIC <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />PHOTOVOLTAIC AC DISCONNECT <br />DUAL POWER SOURCE <br />NOMINAL OPERATING AC VOLTAGE: <br />DC DISCONNECT <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />DO NO TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />WARNING! <br /> INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />WARNING! <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />! <br />WARNING! <br />77.78 <br />240 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />!! <br />LABELING NOTES: <br />1.LABELING REQUIREMENTS BASED ON THE 2022 CALIFORNIA ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. <br />2.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />3.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] <br />4.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC <br />605.11.1.1] <br />AT POINT OF INTERCONNECTION, <br />MARKED AT DISCONNECTING MEANS <br />[CEC 690.54] <br />AT POINT OF INTERCONNECTION. <br />[CEC 705.12(C), 690.59] <br />EACH PV SYSTEM DISCONNECTING MEANS <br />SHALL PLAINLY INDICATE WHETHER IN THE <br />OPEN (OFF) OR CLOSED (ON) POSITION AND <br />BE PERMANENTLY MARKED [CEC. 690.13(B)] <br />AT EACH DC DISCONNECTING MEANS <br />[CEC 690.13(B)] <br />AT EACH AC DISCONNECTING <br />MEANS [CEC 690.13(B)] <br />AT EXPOSED RACEWAYS, CABLE TRAYS, <br />AND OTHER WIRING METHODS; SPACED <br />AT MAXIMUM 10FT SECTION OR WHERE <br />SEPARATED BY ENCLOSURES, WALLS, <br />PARTITIONS, CEILINGS, OR FLOORS <br />[CEC 690.31(D)(2)] <br />AT BUILDING OR STRUCTURE MAIN <br />DISCONNECTING MEANS. [CEC 690.12(E), <br />CEC 690.13(B)] <br />A RAPID SHUTDOWN SWITCH SHALL <br />HAVE A LABEL LOCATED ON OR NO MORE <br />THAN 3 FT FROM THE SWITCH THAT <br />INCLUDES THIS WORDING. THE LABEL <br />SHALL BE REFLECTIVE, WITH ALL <br />LETTERS CAPITALIZED AND HAVING A <br />MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON <br />RED BACKGROUND.[CEC 690.56(C)(2)] <br />FOR PV SYSTEMS THAT SHUT DOWN THE <br />ARRAY AND CONDUCTORS LEAVING THE <br />ARRAY: THE TITLE “SOLAR PV SYSTEM IS <br />EQUIPPED WITH RAPID SHUTDOWN” <br />SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT <br />OF 3/8 IN. IN BLACK ON YELLOW <br />BACKGROUND, AND THE REMAINING <br />CHARACTERS SHALL BE CAPITALIZED <br />WITH A MINIMUM HEIGHT OF 3/16 IN. IN <br />BLACK ON WHITE BACKGROUND. [CEC <br />690.56(C)(1)(A)] <br />A PERMANENT WARNING LABEL SHALL BE <br />APPLIED TO THE DISTRIBUTION <br />EQUIPMENT ADJACENT TO THE <br />BACK-FED BREAKER FROM THE <br />INVERTER. <br />[CEC 705.12(B)(3)(2)] <br />PERMANENT WARNING LABELS SHALL BE <br />APPLIED TO DISTRIBUTION EQUIPMENT <br />E-3 <br />DATE:7/26/2024 <br />swyssling@wysslingconsulting.com <br />(201) 874-3483 <br />DESIGN ENGINEER <br />SOLAR COMPANY/CLIENT <br />76 N. MEADOWBROOK DRIVE <br />ALPINE, UTAH 84004 <br />PV LABELS <br />PLACE LABEL AT MAIN SERVICE PANELCAUTION: DO NOT INSTALL <br />ADDITIONAL LOADS IN THIS PANEL <br />PLACE LABEL AT MAIN SERVICE PANEL <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />WARNING <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />DO NOT ADD LOADS <br />CAUTION AT EXTERNAL LOCATION NEAR METER <br />AND UTILITY SERVICE DISCONNECT <br />TRI POWER SOURCE <br />SECOND SOURCE IS <br />BATTERY THIRD SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />PLACE LABEL EXTERNAL AT MAIN <br />SERVICE DISCONNECTENERGY STORAGE SYSTEM <br />ON SITE LOCATED OUTSIDE <br />PLACE ESS LABELS AT BATTERY AND/OR <br />CONTROLLERWARNING <br />ELECTRIC SHOCK IF A <br />GROUND FAULT IS <br />INDICATED, NORMALLY <br />GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND <br />ENERGIZED <br />AT AC COMBINER PANEL. NEC 690.13(B) <br />ON THE DEAD FRONT BELOW THE TRANSPARENT <br />BREAKER, POSITION THE COVER FOR THE MAINS <br />BREAKER. <br />THE MAXIMUM CURRENT BACKFED BY THIS SYSTEM TO THE MAIN <br />PANEL MAY BE CONTROLLED ELECTRONICALLY. REFER TO THE <br />MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. <br />PC CONTROLLED CURRENT SETTINGS:AMPS44 <br />2307 N Towner St <br />8/23/2024