Laserfiche WebLink
- <br />- <br />- <br />- <br />SOLAREDGE SE80KUS <br />(N) PANELBOARD DP-PV2 <br />300A, 480/277VAC, 3Ø, 4W, NEMA 3R <br />LOCATED ON BLDG E SOUTH ROOF <br />(N) 70A AC DISCONNECT - RSD 1 <br />70A, 600V, 3Ø, 3W, NEMA 3R <br />LOCATED INSIDE BLDG C <br />SOLAREDGE SE100KUS <br />(N) 125A AC DISCONNECT - RSD 2 <br />125A, 600V, 3Ø, 3W, NEMA 3R <br />LOCATED IN BLDG F GYM STORAGE ROOM <br />- <br />SOLAREDGE SE40KUS <br />2 <br />2 <br />2 <br />1.25" EMT CONDUIT <br />(3) #3 AWG CU THWN-2 <br />(1) #8 AWG CU GROUND <br />1.5" EMT CONDUIT <br />(3) #1 AWG CU THWN-2 <br />(1) #6 AWG CU GROUND <br />TO PANELBOARD DP-PV1 <br />70A, 3P CIRCUIT BREAKER <br />1.5" RMC/PVC 40 CONDUIT <br />(3) #2/0 AWG AL XHHW-2 <br />(1) #6 AWG CU GROUND <br />TO PANELBOARD DP-PV1 <br />125A, 3P CIRCUIT BREAKER <br />TO PANELBOARD DP-PV1 <br />250A, 3P CIRCUIT BREAKER <br />M <br />(E) MAIN SWITCHBOARD "MS" <br />3000A, 227/480VAC, 3Ø, 4W, 65KAIC, NEMA 3R <br />W12 <br />5 6 <br />TO PANELBOARD DP-PV11.5" RMC/PVC 40 CONDUIT <br />(3) #1/0 AWG AL XHHW-2 <br />(1) #6 AWG CU THWN-2 GROUND <br />800A <br />43 <br />480V <br />208V <br />(N) XFMR "T-EVC" <br />75KVA, 480V-208/120V <br />#2 AWG CU GEC <br />(E) GROUNDING <br /> ELECTRODE <br />SYSTEM <br />1.25" EMT CONDUIT <br />(3) #1 AWG CU THWN-2 <br />(1) #6 AWG CU GROUND <br />2.5" EMT CONDUIT <br />(4) #350 KCMIL CU THWN-2 <br />(1) #4 AWG CU GROUND <br />3" RMC/PVC 40 CONDUIT <br />(3) #400 KCMIL AL XHHW-2 <br />(1) #4 AWG CU GROUND <br />TO DATA ACQUISTION SYSTEMS <br />DAS ENCLOSURE <br />W5 <br />W6 <br />W8 <br />W9 <br />W10 <br />Ip = 90.3A <br />Is = 208.4A <br />(N) UTILITY PV DISCONNECT <br />800A, 600V, 3Ø, 4W, NEMA 3R <br />LOCATED NEXT TO (E) MSB <br />MODEL NO. SIEMENS HF367NR .SUSE RATED <br />5 <br />5 <br />5 <br />6 <br />8 <br />1 <br />2 <br />- <br />(N) DUAL CHARGEPOINT CP6021B <br />EV CHARGING STATION #1.1 & 1.2 <br />(N) PANELBOARD DP-EV <br />300A, 208/120VAC, 3Ø, 4W, NEMA 3R <br />LOCATED NEXT TO NORTH ELECTRICAL ENCLOSURE <br />1.5" RMC/PVC 40 CONDUIT <br />(3) #4 AWG CU THWN-2 <br />(2) #8 AWG CU GROUND <br />7 <br />(N) SINGLE CHARGEPOINT CP6011B <br />EV CHARGING STATION #2.1 <br />2" EMT CONDUIT <br />(3) #2/0 AWG CU THWN-2 <br />(1) #6 AWG CU GROUND W7 <br />(N) 250A AC DISCONNECT - RSD 3 <br />250A, 600V, 3Ø, 3W, NEMA 3R <br />LOCATED INSIDE BLDG E GROUND LEVEL <br />(N) 30A DC DISCONNECT - RSD 4 <br />LOCATED INSIDE BLDG B ELECTRICAL ROOM <br />FLA=208A <br />TO CUSTOMER NETWORK <br />(2 SETS) <br />3.5" EMT CONDUIT <br />(3) #600 KCMIL CU THWN-2 <br />(1) #3/0 AWG CU THWN-2 NEUTRAL <br />W12 <br />- <br />SOLAREDGE SE40KUS <br />5 <br />- <br />SOLAREDGE SE40KUS <br />ELECTRICAL ROOM <br />5 <br />(N) 70A AC DISCONNECT - RSD 5 <br />70A, 600V, 3Ø, 3W, NEMA 3R <br />LOCATED INSIDE BLDG A ELECTRICAL ROOM <br />TO PANELBOARD DP-PV1 <br />70A, 3P CIRCUIT BREAKER <br />1.5" RMC/PVC 40 CONDUIT <br />(3) #1/0 AWG AL XHHW-2 <br />(1) #6 AWG CU THWN-2 GROUND <br />W5 <br />W7B <br />2 <br />12 <br />13 <br />14 <br />1615 (N) SINGLE CHARGEPOINT CP6011B <br />EV CHARGING STATION #3.1 <br />1" RMC/PVC 40 CONDUIT <br />(3) #4 AWG CU THWN-2 <br />(1) #8 AWG CU THWN-2 GROUND <br />ALL LOCATED ON NORTH <br />SIDE OF PARKING LOT <br />#3/0 AWG CU GEC <br />(E) GROUNDING <br /> ELECTRODE <br />SYSTEM <br />CUSTOMER <br />DATE: <br />SCALE: <br />SHEET # <br />CUSTOMER <br />E-9.2 <br />APN <br />PLAN SET REVISIONS <br />399-031-24 / 399-031-23 <br />6/8/2023 <br />SAMUELI ACADEMY <br />1901/1919 N. FAIRVIEW ST. <br />SANTA ANA, CA. 92705 <br />CONTRACTOR SIGNATURE: <br />DAVID CLEVELAND <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br /> <br />C <br />L <br />A <br />S <br />S <br /> <br />B <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />ENGINEER STAMP <br />PROJECT NUMBER <br />1074220072 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />j <br />o <br />d <br />i <br />a <br />z <br />\ <br />M <br />o <br />t <br />i <br />v <br />e <br /> <br />E <br />n <br />e <br />r <br />g <br />y <br />, <br /> <br />I <br />n <br />c <br />\ <br />M <br />E <br />S <br /> <br />- <br /> <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br /> <br />- <br /> <br />C <br />& <br />I <br />\ <br />O <br />r <br />a <br />n <br />g <br />e <br />w <br />o <br />o <br />d <br /> <br />F <br />o <br />u <br />n <br />d <br />a <br />t <br />i <br />o <br />n <br />\ <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br />\ <br />C <br />A <br />D <br />\ <br />P <br />l <br />a <br />n <br />\ <br />S <br />a <br />m <br />u <br />e <br />l <br />i <br /> <br />A <br />c <br />a <br />d <br />e <br />m <br />y <br />_ <br />M <br />A <br />S <br />T <br />E <br />R <br /> <br />P <br />L <br />A <br />N <br /> <br />S <br />E <br />T <br />_ <br />0 <br />2 <br />- <br />0 <br />9 <br />- <br />2 <br />4 <br />_ <br />R <br />e <br />v <br /> <br />2 <br />. <br />d <br />w <br />g <br /> <br />F <br />e <br />b <br /> <br />1 <br />5 <br />, <br /> <br /> <br />2 <br />0 <br />2 <br />4 <br /> <br />- <br /> <br />9 <br />: <br />1 <br />1 <br />a <br />m <br />SINGLE LINE DIAGRAM <br />SHEET 2 <br />SINGLE LINE DIAGRAM <br />GENERAL NOTES <br />1.ALL EQUIPMENT TO BE LISTED. <br />2.ALL EQUIPMENT WIRING AND GROUNDING SHALL CONFORM TO THE MANUFACTURER'S <br />RECOMMENDED PRACTICES. REFER TO THE INSTALLATION AND USER MANUALS FOR GUIDANCE. <br />3.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND <br />ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC ART. 250.134 AND 250.136. <br />CONTRACTOR TO REFER TO MANUFACTURER'S INSTALLATION MANUAL FOR APPROVED METHOD OF <br />GROUNDING. <br />4.INSTALLATION SHALL COMPLY WITH THE 2019 CEC. <br />5.ALL EXPOSED RACEWAY OPENINGS SHALL BE SEALED USING A SUITABLE METHOD SUCH AS DUCT <br />SEAL. <br />6.MOTIVE ENERGY IS NOT RESPONSIBLE FOR ENGINEERING OF EXISTING CIRCUITS. <br />7.BONDING SHALL BE PROVIDED WHERE NECESSARY TO ENSURE ELECTRICAL CONTINUITY AND THE <br />CAPACITY TO CONDUCT SAFELY ANY FAULT CURRENT IN ACCORDANCE WITH CEC ART. 250. <br />8.THE UTILITY MUST BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY ONSITE GENERATION <br />SYSTEM(S). <br />9.SYSTEM INCLUDING CONDUIT AND CONDUCTORS SHALL BE INSTALLED IN A NEAT AND <br />WORKMANLIKE MANNER IN ACCORDANCE WITH CEC ART. 110.12. ALL ELECTRICAL EQUIPMENT, <br />EXPOSED RACEWAYS, CONDUCTORS, AND CONNECTIONS SHALL BE MECHANICALLY SECURED VIA <br />HARDWARE RATED FOR OUTDOOR AND UV LIGHT EXPOSURE. <br />10.ALL PLAQUES, LABELS AND WARNINGS CAN BE FOUND ON CORRESPONDING LABELS AND WARNINGS <br />SHEETS(S). <br />11.CONNECTORS SHALL BE TORQUE PER DEVICE LISTING OR MANUFACTURER'S RECOMMENDATION. <br />SEE THE MANUFACTURER'S INSTALLATION MANUAL FOR THE SPECIFIC TORQUE VALUES. <br />12.PVC CONDUIT SHALL NOT BE USED UNDER THE CONDITIONS SPECIFIED IN CEC ART. 35.12(A)-(D). <br />13.INTERRUPTING CURRENT RATINGS (KAIC) FOR EQUIPMENT SUCH AS PANELBOARDS, CIRCUIT <br />BREAKERS, FUSES, AND DISCONNECTS HAS BEEN SPECIFIED BASED ON THE RATINGS OF THE MAIN <br />SERVICE UNLESS SPECIFIC FAULT CURRENTS AT THE SITE HAVE BEEN PROVIDED BY THE UTILITY. <br />14.NEW OVERCURRENT PROTECTION DEVICES SHALL HAVE THE SAME INTERRUPTING CURRENT <br />RATING (KAIC) AS THE RATING OF THE PANELBOARD OR SWITCH BOARD IN WHICH THEY ARE <br />LOCATED. <br />15.CONTRACTOR TO VERIFY THE TERMINALS AND BENDING RADII OF PROCURED ELECTRICAL <br />EQUIPMENT ARE APPROPRIATE TO ACCOMMODATE THE SIZE OF THE SPECIFIED CONDUCTORS. <br />16.MODULES AND RACKING SYSTEM MUST BE PROPERLY GROUNDED PER THE GROUNDING METHOD <br />PROVIDED IN THE RACKING MANUFACTURER'S INSTALLATION MANUAL. SEE SHEET E-8 FOR <br />ADDITIONAL INFORMATION. <br />17.CONTRACTOR MAY UPSIZE CONDUIT SIZE WHILE ENSURING CONNECTED ENCLOSURES/EQUIPMENT <br />IS CAPABLE OF ACCOMMODATING LARGER CONDUIT SIZES THAN LISTED. <br />18.SEE SECTION 3 ON SHEET E-1 FOR APPROPRIATE CONDUIT TYPES DEPENDING ON THE <br />INSTALLATION LOCATION OF THE CORRESPONDING CONDUCTORS. <br />LEGEND <br /># <br /># <br />W# <br />KEYNOTES# <br />1.PV SOURCE CIRCUITS CONSIST OF ZNSHINE SOLAR ZXM7-SHLDD144 SERIES / BFG MODULES. SEE <br />SINGLE LINE DIAGRAM FOR NUMBER OF MODULES CONNECTED IN SERIES. <br />VMP = 41.50V <br />VOC = 49.80V <br /> IMP = 13.02A <br /> ISC = 13.77A <br />2.PV SOURCE CIRCUIT CONNECTIONS BETWEEN MODULES AND COMBINER BOXES SHALL BE THE <br />SAME MANUFACTURER AND OF THE SAME MODULE SERIES. THERE SHALL BE NO MIXING <br />MANUFACTURERS OR MODULES FOR ANY CONNECTION POINTS. CONTRACTOR SHALL VERIFY THAT <br />CONDUIT SIZE FOR PV SOURCE CIRCUITS WILL FIT INVERTER SPECIFICATIONS. <br />PV SOURCE CIRCUITS TO USE: <br />-#10 AWG CU 1000/2000V PV WIRE CONDUCTORS PER UL 4703 <br />-#8 AWG CU GROUND <br />-MAXIMUM OF (2) PV SOURCE CIRCUITS PER 1.00 INCH CONDUIT. <br />-MAXIMUM OF (4) PV SOURCE CIRCUITS PER 1.25 INCH CONDUIT. <br />-MAXIMUM OF (6) PV SOURCE CIRCUITS PER 1.50 INCH CONDUIT. <br />3.PROVIDED (3) 800A CLASS L FUSES, MERSEN #A4BY800 OR EQUIVALENT. <br />4.DISCONNECT SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF LOCAL ELECTRIC UTILITY. <br />PROVIDE VISIBLE BLADE DISCONNECT SWITCH WITH HANDLE THAT CAN BE PADLOCKED IN THE OFF <br />POSITION. <br />5.SUPPLY SIDE CONNECTION PER 2022 CEC 705.12(A) IN CUSTOMER SIDE OF MAIN SERVICE. USE <br />COMPRESSION CONNECTORS TO TERMINATE THE CONDUCTORS AT THE SUPPLY SIDE CONNECTION. <br />IF THE NEW CONNECTION TO THE EXISTING SERVICE EQUIPMENT MODIFIES THE EXISTING <br />EQUIPMENT, IT MUST BE RECERTIFIED BY A THIRD PARTY TESTING LABORATORY. <br />6.PER CEC 705.31 OVER CURRENT PROTECTION FOR ELECTRICAL POWER PRODUCTION SOURCE <br />CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS IN <br />ACCORDANCE WITH 705.12(A). THE CONDUCTOR LENGTH SHALL BE LESS THAN 16.5 FT OF CABLE. IF <br />THE CABLE LENGTH IS MORE THAN 16.5 FT, USE APPROPRIATE CABLE LIMITERS AT THE POINT OF <br />INTERCONNECTION. <br />7.TERMINATE EGC AT SAME BUS AS EXISTING EGC TERMINATION. <br />J.D. 10-27-23 <br />J.M. 10-27-23 <br />B.B. 10-27-23 <br />SYSTEM SUMMARY <br />TOTAL MODULES 1092 <br />MODULE POWER 540 <br />TOTAL PV DC SYSTEM SIZE 589.680 kW DCp <br />TOTAL PV AC SYSTEM SIZE 544.970 kW CEC AC <br />MAXIMUM OUTPUT CURRENT 632.15 A <br />N.T.S. <br />2 <br />E9.3 <br />3 <br />E9.3 <br />1/2 <br />E9.3 <br />5 <br />E9.3 <br />2 <br />E9.3 <br />5 <br />E9.3 <br />KETNOTE <br />LABELS & WARNINGS REFERENCING NUMBER. <br />SEE SHEETS E-10 & E-11 <br />COUNDUIT / CONDUCTOR TAG, SEE SHEETS E-5.1 & E-5.2 <br />2 <br />E9.3 <br />5 <br />E9.3 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024