M <br />LOCATED NORTH ELECTRICAL <br />ENCLOSURE <br />DATA ACQUISTION SYSTEMS <br />DAS ENCLOSURE <br />DAS, NEMA 3R <br />WEATHER STATION <br />ENCLOSURE <br />7 <br />7 <br />2 <br />2 <br />2 <br />(N) PANELBOARD DP-PV1 <br />800A, 480VAC, 3Ø, 4W, 42 KAIC, NEMA 3R <br />LOCATED IN NORTH ELECTRICAL ENCLOSURE <br />1.25" RMC/PVC 40 CONDUIT <br />(3) #4 AWG AL XHHW-2 <br />(1) #8 AWG CU GROUND <br />1.25" RMC/PVC 40 CONDUIT <br />(3) #2 AWG AL XHHW-2 <br />(1) #8 AWG CU GROUND <br />FROM 70A AC DISCONNECT RSD 1 <br />FROM 125A AC DISCONNECT <br />FROM PANELBOARD DP-PV2 <br />FROM (N) UTILITY DISCONNECT <br />- <br />- <br />- <br />FROM PANELBOARD DP-EV <br />15A 1P, CIRCUIT BREAKER <br />- <br />2 <br />- <br />2 <br />- <br />W2 <br />W4 <br />W3 <br />W11 <br />SPD <br />2 <br />W4 <br />1.25" RMC/PVC 40 CONDUIT <br />(3) #2 AWG AL XHHW-2 <br />(1) #8 AWG CU GROUND <br />W3 <br />4 <br />4 <br />4 <br />4 <br />4 <br />4 <br />3 <br />8 <br />TO CUSTOMER NETWORK <br />FROM 70A AC DISCONNECT RSD 5 <br />9 <br />9 <br />10 <br />11 <br />10 <br />11 <br />CUSTOMER <br />DATE: <br />SCALE: <br />SHEET # <br />CUSTOMER <br />E-9.1 <br />APN <br />PLAN SET REVISIONS <br />399-031-24 / 399-031-23 <br />6/8/2023 <br />SAMUELI ACADEMY <br />1901/1919 N. FAIRVIEW ST. <br />SANTA ANA, CA. 92705 <br />CONTRACTOR SIGNATURE: <br />DAVID CLEVELAND <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br /> <br />C <br />L <br />A <br />S <br />S <br /> <br />B <br />CON <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br />' <br />S <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br /> <br />1 <br />0 <br />8 <br />9 <br />1 <br />1 <br />7 <br /> <br />C <br />L <br />A <br />S <br />S <br /> <br />B <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />ENGINEER STAMP <br />PROJECT NUMBER <br />1074220072 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />j <br />o <br />d <br />i <br />a <br />z <br />\ <br />A <br />p <br />p <br />D <br />a <br />t <br />a <br />\ <br />L <br />o <br />c <br />a <br />l <br />\ <br />T <br />e <br />m <br />p <br />\ <br />A <br />c <br />P <br />u <br />b <br />l <br />i <br />s <br />h <br />_ <br />2 <br />0 <br />1 <br />2 <br />8 <br />\ <br />S <br />a <br />m <br />u <br />e <br />l <br />i <br /> <br />A <br />c <br />a <br />d <br />e <br />m <br />y <br />_ <br />M <br />A <br />S <br />T <br />E <br />R <br /> <br />P <br />L <br />A <br />N <br /> <br />S <br />E <br />T <br />_ <br />1 <br />0 <br />- <br />2 <br />6 <br />- <br />2 <br />3 <br />. <br />d <br />w <br />g <br /> <br />N <br />o <br />v <br /> <br />0 <br />7 <br />, <br /> <br /> <br />2 <br />0 <br />2 <br />3 <br /> <br />- <br /> <br />3 <br />: <br />5 <br />8 <br />p <br />m <br />SINGLE LINE DIAGRAM <br />SINGLE LINE DIAGRAM <br />GENERAL NOTES <br />1. ALL EQUIPMENT TO BE LISTED. <br />2. ALL EQUIPMENT WIRING AND GROUNDING SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDED <br />PRACTICES. REFER TO THE INSTALLATION AND USER MANUALS FOR GUIDANCE. <br />3. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND <br />ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC ART. 250.134 AND 250.136. <br />CONTRACTOR TO REFER TO MANUFACTURER'S INSTALLATION MANUAL FOR APPROVED METHOD OF <br />GROUNDING. <br />4. INSTALLATION SHALL COMPLY WITH THE 2019 CEC. <br />5. ALL EXPOSED RACEWAY OPENINGS SHALL BE SEALED USING A SUITABLE METHOD SUCH AS DUCT SEAL. <br />6. MOTIVE ENERGY IS NOT RESPONSIBLE FOR ENGINEERING OF EXISTING CIRCUITS. <br />7. BONDING SHALL BE PROVIDED WHERE NECESSARY TO ENSURE ELECTRICAL CONTINUITY AND THE <br />CAPACITY TO CONDUCT SAFELY ANY FAULT CURRENT IN ACCORDANCE WITH CEC ART. 250. <br />8. THE UTILITY MUST BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY ONSITE GENERATION <br />SYSTEM(S). <br />9. SYSTEM INCLUDING CONDUIT AND CONDUCTORS SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE <br />MANNER IN ACCORDANCE WITH CEC ART. 110.12. ALL ELECTRICAL EQUIPMENT, EXPOSED RACEWAYS, <br />CONDUCTORS, AND CONNECTIONS SHALL BE MECHANICALLY SECURED VIA HARDWARE RATED FOR <br />OUTDOOR AND UV LIGHT EXPOSURE. <br />10. ALL PLAQUES, LABELS AND WARNINGS CAN BE FOUND ON CORRESPONDING LABELS AND WARNINGS <br />SHEETS(S). <br />11. CONNECTORS SHALL BE TORQUE PER DEVICE LISTING OR MANUFACTURER'S RECOMMENDATION. SEE <br />THE MANUFACTURER'S INSTALLATION MANUAL FOR THE SPECIFIC TORQUE VALUES. <br />12. PVC CONDUIT SHALL NOT BE USED UNDER THE CONDITIONS SPECIFIED IN CEC ART. 35.12(A)-(D). <br />13. INTERRUPTING CURRENT RATINGS (KAIC) FOR EQUIPMENT SUCH AS PANELBOARDS, CIRCUIT <br />BREAKERS, FUSES, AND DISCONNECTS HAS BEEN SPECIFIED BASED ON THE RATINGS OF THE MAIN <br />SERVICE UNLESS SPECIFIC FAULT CURRENTS AT THE SITE HAVE BEEN PROVIDED BY THE UTILITY. <br />14. NEW OVERCURRENT PROTECTION DEVICES SHALL HAVE THE SAME INTERRUPTING CURRENT RATING <br />(KAIC) AS THE RATING OF THE PANELBOARD OR SWITCH BOARD IN WHICH THEY ARE LOCATED. <br />15. CONTRACTOR TO VERIFY THE TERMINALS AND BENDING RADII OF PROCURED ELECTRICAL EQUIPMENT <br />ARE APPROPRIATE TO ACCOMMODATE THE SIZE OF THE SPECIFIED CONDUCTORS. <br />16. MODULES AND RACKING SYSTEM MUST BE PROPERLY GROUNDED PER THE GROUNDING METHOD <br />PROVIDED IN THE RACKING MANUFACTURER'S INSTALLATION MANUAL. SEE SHEET E-8 FOR ADDITIONAL <br />INFORMATION. <br />17. CONTRACTOR MAY UPSIZE CONDUIT SIZE WHILE ENSURING CONNECTED ENCLOSURES/EQUIPMENT IS <br />CAPABLE OF ACCOMMODATING LARGER CONDUIT SIZES THAN LISTED. <br />18. SEE SECTION 3 ON SHEET E-1 FOR APPROPRIATE CONDUIT TYPES DEPENDING ON THE INSTALLATION <br />LOCATION OF THE CORRESPONDING CONDUCTORS. <br />LEGEND <br /># <br />KETNOTE <br />LABELS & WARNINGS REFERENCING NUMBER. <br />SEE SHEETS E-10 & E-11 <br /># <br />W#COUNDUIT / CONDUCTOR TAG, SEE SHEETS E-5.1 & E-5.2 <br />KEYNOTES# <br />1. PV SOURCE CIRCUITS CONSIST OF ZNSHINE SOLAR ZXM7-SHLDD144 SERIES / BFG MODULES. <br />SEE SINGLE LINE DIAGRAM FOR NUMBER OF MODULES CONNECTED IN SERIES. <br />VMP = 41.50V <br />VOC = 49.80V <br /> IMP = 13.02A <br /> ISC = 13.77A <br />2. PV SOURCE CIRCUIT CONNECTIONS BETWEEN MODULES AND COMBINER BOXES SHALL BE THE <br />SAME MANUFACTURER AND OF THE SAME MODULE SERIES. THERE SHALL BE NO MIXING <br />MANUFACTURERS OR MODULES FOR ANY CONNECTION POINTS. CONTRACTOR SHALL VERIFY <br />THAT CONDUIT SIZE FOR PV SOURCE CIRCUITS WILL FIT INVERTER SPECIFICATIONS. <br />PV SOURCE CIRCUITS TO USE: <br />-#10 AWG CU 1000/2000V PV WIRE CONDUCTORS PER UL 4703 <br />-#8 AWG CU GROUND <br />-MAXIMUM OF (2) PV SOURCE CIRCUITS PER 1.00 INCH CONDUIT. <br />-MAXIMUM OF (4) PV SOURCE CIRCUITS PER 1.25 INCH CONDUIT. <br />-MAXIMUM OF (6) PV SOURCE CIRCUITS PER 1.50 INCH CONDUIT. <br />3. PROVIDED (3) 800A CLASS L FUSES, MERSEN #A4BY800 OR EQUIVALENT. <br />4. DISCONNECT SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF LOCAL ELECTRIC <br />UTILITY. PROVIDE VISIBLE BLADE DISCONNECT SWITCH WITH HANDLE THAT CAN BE PADLOCKED <br />IN THE OFF POSITION. <br />5. SUPPLY SIDE CONNECTION PER 2022 CEC 705.12(A) IN CUSTOMER SIDE OF MAIN SERVICE. USE <br />COMPRESSION CONNECTORS TO TERMINATE THE CONDUCTORS AT THE SUPPLY SIDE <br />CONNECTION. IF THE NEW CONNECTION TO THE EXISTING SERVICE EQUIPMENT MODIFIES THE <br />EXISTING EQUIPMENT, IT MUST BE RECERTIFIED BY A THIRD PARTY TESTING LABORATORY. <br />6. PER CEC 705.31 OVER CURRENT PROTECTION FOR ELECTRICAL POWER PRODUCTION SOURCE <br />CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS IN <br />ACCORDANCE WITH 705.12(A). THE CONDUCTOR LENGTH SHALL BE LESS THAN 16.5 FT OF <br />CABLE. IF THE CABLE LENGTH IS MORE THAN 16.5 FT, USE APPROPRIATE CABLE LIMITERS AT <br />THE POINT OF INTERCONNECTION. <br />7. MONITORING SHALL INCLUDE RS-485 BELDEN 3106A OR EQUIVALENT FOR COMMUNICATION. <br />REFER TO MONITORING SYSTEM DIAGRAM AND INSTALLATION MANUAL FOR ADDITIONAL <br />DETAILS. <br />8. PROVIDE SURGE PROTECTIVE DEVICE 150KA/PHASE, 3PH, 4W, GROUND 480Y/277V SYSTEM, <br />MERSEN STXT480Y20 OR EQUIVALENT. <br />J.D. 10-27-23 <br />J.M. 10-27-23 <br />B.B. 10-27-23 <br />SYSTEM SUMMARY <br />TOTAL MODULES 1092 <br />MODULE POWER 540 <br />TOTAL PV DC SYSTEM SIZE 589.680 kW DCp <br />TOTAL PV AC SYSTEM SIZE 544.970 kW CEC AC <br />MAXIMUM OUTPUT CURRENT 632.15 A <br />N.T.S. <br />2 <br />E9.3 <br />4 <br />E9.3 <br />2 <br />E9.3 <br />2 <br />E9.3 <br />4 <br />E9.3 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024