My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairview St
>
1901 N Fairview St Bldg# B
>
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 2:00:13 AM
Creation date
6/6/2025 1:22:19 PM
Metadata
Fields
Template:
Plan
Permit Number
20180424
20180427
20180439
20180441
20180444
101116031
101119651
Full Address
1901 N Fairview St Bldg# B
1901 N Fairview St Bldg# C
1919 N Fairview St Bldg# E
1901 N Fairview St Bldg# F
1901 N Fairview St
Street Number
1901
1901
1919
1901
1901
Street Direction
N
N
N
N
N
Street Name
Fairview
Fairview
Fairview
Fairview
Fairview
Street Suffix
St
St
St
St
St
Building Number
B
C
E
F
Permit Number (Not in SAPIN)
2018049
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
694
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project Name:Samueli Academy-Bldg A Engineer:Elie Sayegh, PE <br />Project No.:1074220072 Date: <br />Racking System Proposed:Panel Claw FR 5 <br />Racking System Type:Ballasted - Hybrid <br />Reserved Capacity: 6.00 psf, maximum allowable dist. Load of PV system (see calc. section C) <br />Max. Anticipated Point Load:306 lbs, 130# DL and 293# WL - Combo D + 0.6W (see calc. section D & G) <br />Max. Allowable System Weight:45 kips (see calc. section C) <br />Typical Connection: 8 - #12 screws from racking system to roof sheathing <br />Maximum allowable Uplfit:525 lbs <br />Maximum Allowable Shear:650 lbs <br />Max. Contact Pressure 17 psi <br />Lateral Loads Sections - IEBC & CBC <br />Gravity Loads Sections - IEBC & CBC <br />Live Loads - ASCE7-16 Chapter 4, Section 4.17 <br />2/16/2024 <br />B. Results Summary, Assumptions & Conditions <br />Solar System Description <br />Client/Owner is planing to install rooftop solar arrays on the project site existing building(s). Summarized below <br />are the maximum loads that may be imposted on the subject structure based on Motive's review of available & <br />collected building data/information <br />Applicable Building Code Excerpts <br />Attachment Capacities (Not Required @ Fully Balasted Systems) <br />Insulation Pressure Capacity <br />Standard Foam insulation have a 16 psi minimum compressive strength. Refer to Polyiso <br />foam board ASTM C-1289. Compressive strength ranges from 16 to 25 psi. Therefore, <br />foam insulation is capable of supporting the said ballasted system. <br />Lateal loads resisted by an (E) member or an (E) LFRS may be increased by up to 10% <br />without a need to retrofit/assess the member or system. <br />Gravity loads resisted by an (E) member may be increased by up to 5% without a need to <br />retrofit/assess the member or system. <br />When solar panels/arrays are installed/positioned 24" or less above the surface of the <br />building roof or where proper signing restricting storage/access to below solar panels is <br />present, reporpusing the Live Load Capacity for solar Arrays is permissible. <br />Basis of Design Conditions & Assumptions <br />P- 9 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.