My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairview St
>
1901 N Fairview St Bldg# B
>
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 2:00:13 AM
Creation date
6/6/2025 1:22:19 PM
Metadata
Fields
Template:
Plan
Permit Number
20180424
20180427
20180439
20180441
20180444
101116031
101119651
Full Address
1901 N Fairview St Bldg# B
1901 N Fairview St Bldg# C
1919 N Fairview St Bldg# E
1901 N Fairview St Bldg# F
1901 N Fairview St
Street Number
1901
1901
1919
1901
1901
Street Direction
N
N
N
N
N
Street Name
Fairview
Fairview
Fairview
Fairview
Fairview
Street Suffix
St
St
St
St
St
Building Number
B
C
E
F
Permit Number (Not in SAPIN)
2018049
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
694
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. <br />2. <br />3. <br />4. <br />5. <br />6.Overflow roof drains/scuppers are provided & a ponding anlysis is not required <br />The Analsyis provided herein is based on information collected from one or more of the following <br />sources: existing building plans, data captured during site observations completed by Motive or <br />outside consultant, photo evidence collected from drone footage. <br />The structure(s) is in GOOD conditions and able to support and resist the loads it was originally <br />designed for. Additionally, it is assumed that there has been no damages to the main Vertical and <br />Lateral Systems and that structural retrofits are not required. It is the Owner's responsibility to <br />maintain the building's good and safe conditions. <br />The building(s) has not been altered when compared to its original construction and is in <br />conformance with approved bldg. plans if such plans exist. Alternations include but are not limited <br />to additions, re-roofing overlays, addition of roof supported MEP units or replacement of exisitng <br />equipment with ones that are heavier, removal of bearing or non-bearing walls, replacement of <br />existing finish with a heavier one, or story additions. <br />The analysis provided in this submittal correspond to the (E) structure. All existing connections are <br />assumed to have been designed to carry and transfer the load capacity/reactions of the members <br />they are intended to support. <br />The calculations are applicable to the addition of new solar arrays. Future additions or alterations <br />shall be examined and approved by a professional engineer and shall account for the added solar <br />P- 10 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.