My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2039 N Victoria Dr - REV 2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Victoria Dr
>
2039 N Victoria Dr
>
2039 N Victoria Dr - REV 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 2:57:49 AM
Creation date
6/6/2025 1:22:21 PM
Metadata
Fields
Template:
Plan
Permit Number
101117695
101119812
Full Address
2039 N Victoria Dr
Street Number
2039
Street Direction
N
Street Name
Victoria
Street Suffix
Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE: 1/22/2025 COMPANY: JRS Engineering & Design LLC <br />STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer <br />CUSTOMER: REVIEWED BY: -- <br />PROJ. ADDRESS: <br />-- <br />PROJECT SUMMARY <br />Project Name: 2039 Victoria Dr - Patio Cover <br />Governing Codes:Building Code: 2022 California Building CodeASCE: ASCE 7-22Steel: AISC 360-16Concrete: ACI 318-19Masonry: TMS 402/602-16 <br />Page 1 <br />2022 California Building Code ASDPROJECT: 2039 Victoria Dr - Patio Cover <br />Module Location: Patio Roof Rafter <br />Module Level: Roof <br />Module Type: Roof Rafter <br />Material Type: Solid Sawn Douglas Fir-Larch No. 2 <br />Member Dimensions: (1) 1.5 in. X 5.5 in. X 9.19 ft @ 24 in. Spacing <br />Section Adequacy:9.43% <br />Controlling Factor: Bending Stress Y <br />Module Location: Patio Roof Ridge <br />Module Level: Roof <br />Module Type: Roof Beam <br />Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam <br />PSL <br />Member Dimensions: (1) 5.25 in. X 16 in. X 27.75 ft <br />Section Adequacy:34.69% <br />Controlling Factor: Bending Stress Y <br />Module Location: Roof King Post Beam <br />Module Level: Roof <br />Module Type: Roof Beam <br />Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam <br />PSL <br />Member Dimensions: (1) 3.5 in. X 14 in. X 19.12 ft <br />Section Adequacy:8.37% <br />Controlling Factor: Bending Stress Y <br />Module Location: Eave Beam <br />Module Level: Roof <br />Module Type: Roof Beam <br />Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam <br />PSL <br />Member Dimensions: (1) 3.5 in. X 9.25 in. X 13.88 ft <br />Section Adequacy:65.89% <br />Controlling Factor: Bending Stress Y <br />Module Location: PSL top plate (Door Header with Ridge) <br />Module Level: Main Floor <br />Module Type: Floor Beam <br />Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam <br />PSL <br />Member Dimensions: (1) 3.5 in. X 9.25 in. X 11.17 ft <br />Section Adequacy:18.11% <br />Controlling Factor: Shear Stress Y <br />Module Location: King Post Footing <br />Module Level: Basement <br />Module Type: Isolated Footing <br />Material Type: Concrete <br />Member Dimensions: 2 ft. wide X 24 in. tall X 2 ft long <br />Section Adequacy:9.83% <br />Controlling Factor: Soil Bearing Pressure <br />2039 N Victoria Dr - REV <br />24/22/2025