Page 2 <br />2022 California Building Code ASDPROJECT: 2039 Victoria Dr - Patio Cover <br />Reinforcement: # 4 - Longitudinal: 6 Bars. Transversal: 6 Bars <br />Module Location: Existing Footing (Supporting PSL Header End) <br />South <br />Module Level: Basement <br />Module Type: Continuous Footing <br />Material Type: Concrete <br />Member Dimensions: 1 ft. wide X 12 in. tall <br />Section Adequacy:7.12% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: # 4 - Longitudinal: 0 Bars. Transversal: 6" O.C. Spacing <br />Module Location: Existing Footing (Supporting PSL Header End) <br />North <br />Module Level: Basement <br />Module Type: Isolated Footing <br />Material Type: Concrete <br />Member Dimensions: 1 ft. wide X 12 in. tall X 2 ft long <br />Section Adequacy:3.6% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: Unreinforced (Plain) <br />Module Location: Eave Post Footing <br />Module Level: Basement <br />Module Type: Isolated Footing <br />Material Type: Concrete <br />Member Dimensions: 2 ft. wide X 24 in. tall X 2 ft long <br />Section Adequacy:37.5% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: # 4 - Longitudinal: 6 Bars. Transversal: 6 Bars <br />2039 N Victoria Dr - REV <br />24/22/2025