Laserfiche WebLink
DEMOLITION PLAN LEGEND <br />EXISTING PARTITION TO BE DEMOLISHED <br />EXISTING PARTITION TO REMAIN <br />ACOUSTICAL CEILING SYSTEM TO BE DEMOLISHED <br />EXISTING DOOR & FRAME TO BE DEMOLISHED <br />EXISTING DOOR & FRAME TO REMAIN <br />GYP. BOARD CEILING TO BE DEMOLISHED <br />1. DEMOLITION GENERAL NOTES APPLY TO ALL DEMOLITION SHEETS. <br />2. COORDINATE DEMOLITION AND PHASING EFFORTS WITH ARCHITECT AND <br />OWNER'S REPRESENTATIVES. EVERY EFFORT SHALL BE MADE TO MINIMIZE <br />DISRUPTION OF OWNER'S OPERATIONS AND TO PROVIDE BUILDING USER'S <br />SAFETY. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND <br />COORDINATED WITH OWNER'S REPRESENTATIVE AND LANDLORD. <br />3. VERIFY EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS AND NOTIFY <br />ARCHITECT OF DISCREPANCIES. <br />4. VERIFY AND MAINTAIN LOCATION OF EXISTING POWER, COMMUNICATION AND <br />DATA CABLES TO PREVENT INTERRUPTION OF SERVICE. <br />5. COORDINATE DISRUPTION OF UTILITY SERVICES WITH OWNER, LANDLORD AND AS <br />SPECIFIED. <br />6. EXISTING MATERIALS SHALL NOT BE REUSED UNLESS NOTED OTHERWISE OR AS <br />AUTHORIZED BY ARCHITECT. <br />7. THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE ANY MATERIALS. <br />8. PROVIDE PROTECTION FOR EXISTING BUILDING MATERIALS AND EQUIPMENT FROM <br />DAMAGE DUE TO DEMOLITION OR CONSTRUCTION-RELATED INCIDENT <br />PERFORMED UNDER THIS CONTRACT. <br />9. REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF DEMOLITION OR <br />CONSTRUCTION TO MATCH EXISTING FINISH AND /OR CONDITION. <br />10. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN EXISTING BUILDING <br />WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE DEMOLITION AND <br />CONSTRUCTION WORK FROM GENERAL PUBLIC AND AS DEEMED NECESSARY BY <br />OWNER AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS <br />WITH OWNER AND LANDLORD. MAINTAIN MEANS OF EGRESS THROUGHOUT THE <br />WORK. <br />11. MAINTAIN A SECURE, DUST-PROOF, WEATHER-TIGHT ENCLOSURE. <br />12. WHERE PLASTER/STUD WALLS ARE INDICATED TO BE REMOVED; PREPARE <br />ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING ADJACENT <br />PLASTER FINISH A MINIMUM OF 12 INCHES BEYOND DEMOLITION. <br />13. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR <br />REROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, ETC. AS <br />REQUIRED TO MAINTAIN FIRE SEPARATIONS. MATCH FINISH OF NEW OR EXISTING <br />ADJACENT SURFACES <br />14. CAP DISCONNECTED MECHANICAL PIPING LINES WITHIN WALL OR FLOOR. PATCH <br />AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES. <br />15. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER <br />SEQUENCING AND SCOPE OF WORK. <br />16. SUITE HAS 2 EXISTING 200 AMP ELECTRICAL PANELS THAT CAN BE RELOCATED <br />FOR NEW LAYOUT. <br />17. ON ROOF WHERE EQUIPMENT IS SITTING THERE IS EQUIPMENT ABANDONED AND A <br />LOT OF DEBRIEF THAT NEED TO ME REMOVE AND HAUL AWAY, AND DO A POSSIBLE <br />ROOF REPAIR AFTER REMOVAL. <br />DEMOLITION PLAN NOTES <br />DEMOLITION PLAN KEYNOTES <br />ENRTY <br />ENRTY <br />W-2 <br />W-2 <br />W-4 <br />W-1 <br />202 <br />202 <br />203 <br />201 <br />201 <br />204 <br />204 <br />ENRTY <br />202 <br />205 206 <br />207 <br />207 <br />204 <br />209 209 <br />210 <br />W-1 <br />210 <br />A-3.02 8 <br />12 <br />13 <br />WALL TYPES LEGEND <br />NEW INTERIOR PARTITION METAL STUD WALL: <br />• 5/8" GYP. BD. <br />• 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. <br />• SOUND ATTENUATION BATT INS. <br />• 5/8" GYP. BD. <br />• WALL HEIGHT: 11'-0" <br />1i <br />1i <br />W-7 <br />W-8 <br />EXISTING STOREFRONT TO REMAIN1iW-1 <br />1iW-9 <br />EXISTING EXTERIOR CMU WALL TO REMAIN, TYP.1iW-2 <br />EXISTING INTERIOR FURR WALL TO REMAIN, TYP.1iW-4 <br />NEW INTERIOR PARTITION LOW METAL STUD WALL: <br />• 5/8" GYP. BD. <br />• 3-5/8" MIN. 25 GA. METAL STUD @ 16" O.C. <br />• SOUND ATTENUATION BATT INS. PROVIDE LATERAL BRACING POST <br /> @4'-0" O.C. <br />• 5/8" GYP. BD. <br />• WALL HEIGHT: 7'-0" <br />NEW INTERIOR PARTITION WET METAL STUD WALL: <br />• 5/8" MOISTURE RESISTANT GYP. BD. <br />• 6" MIN. 25 GA. METAL STUD @ 16" O.C. & R-13 MIN. <br />• SOUND ATTENUATION BATT INS. <br />• 5/8" MOISTURE RESISTANT GYP. BD. <br />• WALL HEIGHT: 9'-0" <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />4 <br />: <br />5 <br />0 <br /> <br />P <br />M <br />DEMO FLOOR PLAN <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />1/4" = 1'-0"1 EXISTING / DEMOLITION FLOOR PLAN <br />201 (E) EXTERIOR WALL W/STUCCO FINISH TO REMAIN. TYP. <br />202 (E) STOREFRONT GLASS SYSTEM TO REMAIN, TYP. <br />203 (E) STOREFRONT ENTRY DOOR TO REMAIN, TYP. <br />204 (E) FULL HEIGHT INT. PARTITION WALL TO BE DEMOLISHED. <br />PREP AREA FOR (N) CONSTRUCTION, TYP. <br />205 (E) CONTRACTOR TO REVIEW W/ TENANT AND BUILDING <br />OWNER ON (E) ITEMS TO BE REUSED SUCH AS DOORS, <br />FRAMES, LIGHTING, SWITCHES, POWER RECEPTACLES, <br />AND PHONE/DATA JACKS, ETC. <br />206 (E) GENERAL CONTRACTOR TO VERIFY IF ANY DEMOLISHED <br />WALLS OR COLUMN FURRING CONTAIN MECHANICAL OR <br />PLUMBING & ADVISE CLIENT & ARCHITECT. <br />207 (E) CEILING SYSTEM TO BE DEMOLISHED. <br />209 (E) REMOVE ALL TENANT SUPPLIED HVAC UNITS. <br />210 (E) DOOR AND FRAME TO BE DEMOLISHED. <br />No. Description Date