My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1414 W Edinger Ave - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1414 W Edinger Ave
>
1414 W Edinger Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:58 PM
Creation date
6/6/2025 1:22:21 PM
Metadata
Fields
Template:
Plan
Permit Number
20184135
30147841
40139567
101121037
Full Address
1414 W Edinger Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MEANS OF EGRESS LEGEND <br />EXITING PATH OF TRAVEL <br />EXIT SIGN <br />EXITING PATH OF TRAVEL <br />DIRECTIONAL SPLIT POINT & TRAVEL <br />DISTANCE <br />FIRE EXTINGUISHER CABINET (FEC) <br />REQUIRED MEANS OF EGRESS. SEE DETAIL 10/G-07 FOR MORE SPECS. EXIT <br />A <br />1 <br />2 <br />FEC <br />INTERIOR EXIT ROUTE SIGN. SEE DETAIL 10/G-07 FOR MORE SPECS.EXIT <br />ROUTE <br />EXIT <br />ILLUMIN.ILLUMINATED EXIT SIGN. REFER TO NOTES ON SHEET G-08. <br />EGRESS PLAN CODE ANALYSIS <br />EGRESS PLAN TRAVEL DISTANCES <br />"A" TO "1" = 74' - 11" <br />"A" TO "2" = 68' - 1" <br />"B" TO "1" = 121' - 2" <br />"B" TO "2" = 65' - 8" <br />"C" TO "1" = 59' - 2" <br />"C" TO "2" = 28' - 8" <br />A. MEANS OF EGRESS SIZING - CBC 2022 SECTION 1005 <br />OCCUPANT LOAD 97 <br />DOORS: 2 DOOR WIDTH PROVIDED = 72" <br />B. NUMBER OF EXITS - CBC 2022 SECTION 1015 <br />(2) EXITS REQUIRED FOR SPACES WITH OCCUPANT LOAD BELOW 501 <br />NUMBER OF EXITS PROVIDED = 2 <br />C. SEPARATION OF EXITS - CBC 2022 SECTION 1017.1.1 <br />EXITS MUST BE SEPARATED BY AT LEAST 1/2 OVERALL DIAGONAL DISTANCE IN THE SPACE <br />78' - 0" /2 = 39' - 0" <br />1/2 DIAGONAL = 39' - 0" <br />56' - 8" > 39' - 0" <br />D. TRAVEL DISTANCE - CBC 2022 SECTION 1017.12 <br />THE MOST REMOTE POINT IN THE SPACE IS 121' - 2" TO THE EXIT WHICH IS LESS THAN THE <br />MAXIMUM 200' - 0" PERMITTED IN A FULLY SPRINKLERED BUILDING <br />OFFICE/IT <br />122 <br />EXAM ROOM <br />136 <br />EXAM ROOM <br />135 <br />EXAM ROOM <br />134 <br />EXAM ROOM <br />133 <br />LOUNGE <br />132 <br />UTILITY <br />131 <br />EXAM ROOM <br />130 <br />EXAM ROOM <br />129 <br />EXAM ROOM <br />128 <br />EXAM ROOM <br />127 <br />LAB <br />126 <br />WAITING AREA <br />120 <br />RECEPTION <br />125 <br />CORRIDOR <br />137 <br />TOILET <br />124 <br />TOILET <br />123 <br />PLAY AREA <br />121 <br />78' DIAGONAL DISTANCE (39'-0" MIN DOOR SEPARATION 1/2) <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+34" AFF. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />+3 <br />4 <br />" <br /> <br />A <br />F <br />F <br />. <br />30"x42" MIN <br />CLR. <br />30"x42" MIN <br />CLR. <br />30"x42" MIN <br />CLR. <br />30"x42" MIN <br />CLR. <br />30 <br />" <br />x <br />4 <br />2 <br />" <br /> <br />M <br />I <br />N <br /> <br />CL <br />R <br />. <br />30 <br />" <br />x <br />4 <br />2 <br />" <br /> <br />M <br />I <br />N <br /> <br />CL <br />R <br />. <br />30 <br />" <br />x <br />4 <br />2 <br />" <br /> <br />M <br />I <br />N <br /> <br />CL <br />R <br />. <br />30 <br />" <br />x <br />4 <br />2 <br />" <br /> <br />M <br />I <br />N <br /> <br />CL <br />R <br />. <br />+34" AFF. <br />+4 <br />2 <br />" <br /> <br />A <br />F <br />F <br />. <br />+30" AFF. MIN <br />+30" AFF. MIN <br />+34" AFF. <br />+34" AFF. <br />DO <br />O <br />R <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br /> <br />2 <br />% <br /> <br />M <br />A <br />X <br /> <br />SL <br />O <br />P <br />E <br />60" <br />18 <br />" <br />60 <br />" <br />18"60" <br />60 <br />" <br />18 <br />" <br />60" <br />60" <br />18 <br />" <br />60 <br />" <br />18" <br />60" <br />18 <br />" <br />27 <br />" <br />60" <br />ADA <br />WHEELCHAIR <br />60" <br />DO <br />O <br />R <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br /> <br />2 <br />% <br /> <br />M <br />A <br />X <br /> <br />SL <br />O <br />P <br />E <br />48" <br />1 <br />2 <br />C <br />FEC <br />FE <br />C <br />FE <br />C <br />FEC <br />63 <br />" <br />2% <br />SLOPE <br />18 <br />" <br />18 <br />" <br />18" <br />A <br />B <br />EXIT <br />EXIT <br />EXIT <br />ROUTE <br />EXIT <br />ILLUMIN. <br />EXIT <br />ILLUMIN. <br />56'-8" DOOR SEPARATION <br />EXIT <br />ROUTE 2 <br />1. EVERY ROOM OR SPACE WHICH IS USED FOR ASSEMBLY, CLASSROOM, DINING, <br />DRINKING OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE <br />SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A <br />CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM <br />THE ROOM OR SPACE, FOR THE INTENDED CONFIGURATIONS. POSTED SIGNS <br />SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE <br />MAINTAINED BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT. CBC 1004.9 <br />2. DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED DIMENSION <br />BY MORE THAN 7 INCHES (178 MM). WHERE A LANDING SERVES AN OCCUPANT <br />LOAD OF 50 OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING <br />TO LESS THAN ONE-HALF ITS REQUIRED WIDTH.CBC 1010.1.5 <br />3. SIDE-HINGED SWINGING DOORS, PIVOTED DOORS AND BALANCED DOORS SHALL <br />SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA <br />CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H <br />OCCUPANCY. CBC 1010.1.2.1 <br />4. THE FORCES TO UNLATCH DOORS SHALL COMPLY WITH THE FOLLOWING: <br />WHERE DOOR HARDWARE OPERATES BY PUSH OR PULL, THE OPERATIONAL <br />FORCE TO UNLATCH THE DOOR SHALL NOT EXCEED 15 POUNDS (67 N). <br />WHERE DOOR HARDWARE OPERATES BY ROTATION, THE OPERATIONAL FORCE TO <br />UNLATCH THE DOOR SHALL NOT EXCEED 28 INCH-POUNDS (315 N-CM). <br />THE FORCE TO OPEN DOORS SHALL COMPLY WITH THE FOLLOWING: <br />FOR INTERIOR SWINGING EGRESS DOORS THAT ARE MANUALLY OPERATED, <br />OTHER THAN DOORS REQUIRED TO BE FIRE RATED, THE FORCE FOR PUSHING OR <br />PULLING OPEN THE DOOR SHALL NOT EXCEED 5 POUNDS (22 N). <br />FOR OTHER SWINGING DOORS, SLIDING DOORS OR FOLDING DOORS, AND DOORS <br />REQUIRED TO BE FIRE RATED, THE DOOR SHALL REQUIRE NOT MORE THAN A 30- <br />POUND (133 N) FORCE TO BE SET IN MOTION AND SHALL MOVE TO A FULL-OPEN <br />POSITION WHEN SUBJECTED TO NOT MORE THAN A 15-POUND (67 N) FORCE.CBC <br />1010.1.3 <br />5. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT LOAD OF 300 OR <br />LESS, GROUPS B, F, M AND S, AND IN PLACES OF RELIGIOUS WORSHIP, THE MAIN <br />DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED <br />LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: <br />-THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED. <br />-A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR <br />ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN THIS <br />SPACE IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A <br />CONTRASTING BACKGROUND. <br />-THE USE OF THE KEY-OPERATED LOCKING DEVICE IS REVOCABLE BY THE <br />BUILDING OFFICIAL FOR DUE CAUSE.CBC 1010.2.4. <br />6. PROVIDE A TACTILE SIGN AT ALL REQUIRED EXIT DOORS. SEE SHEET G-08 FOR <br />MORE INFORMATION OF SIGNS. <br />7. THE REQUIRED CAPACITY OF EXIT PASSAGEWAYS SHALL BE DETERMINED AS <br />SPECIFIED IN SECTION 1005.1 BUT THE MINIMUM WIDTH SHALL BE NOT LESS THAN <br />44 INCHES (1118 MM), EXCEPT THAT EXIT PASSAGEWAYS SERVING AN OCCUPANT <br />LOAD OF LESS THAN 50 SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN WIDTH. <br />THE MINIMUM WIDTH OR REQUIRED CAPACITY OF EXIT PASSAGEWAYS SHALL BE <br />UNOBSTRUCTED. CBC 1024.2 <br />8. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. SEE SHEET G-08 <br />FOR MORE INFORMATION OF THE SIGNS. <br />9. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. CODE 1013.5 . SEE SHEET G-08 <br />FOR MORE INFORMATION. <br />10. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL <br />PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY <br />POWER LOSS. CBC 1013.6.3 <br />EGRESS PLAN NOTES <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />4 <br />: <br />4 <br />9 <br /> <br />P <br />M <br />EGRESS PLAN <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />AREA / OCCUPANCY ANALYSIS <br />ROO <br />M #ROOM NAME AREA LOAD OCC. # <br />122 OFFICE/IT 106 SF 150 1 <br />136 EXAM ROOM 163 SF 150 2 <br />135 EXAM ROOM 121 SF 150 1 <br />134 EXAM ROOM 121 SF 150 1 <br />132 LOUNGE 125 SF 15 9 <br />131 UTILITY 53 SF 150 1 <br />125 RECEPTION 226 SF 150 2 <br />120 WAITING AREA 604 SF 15 41 <br />121 PLAY AREA 375 SF 15 25 <br />123 TOILET 53 SF 150 1 <br />124 TOILET 53 SF 150 1 <br />137 CORRIDOR 140 SF 150 1 <br />133 EXAM ROOM 121 SF 150 1 <br />126 LAB 130 SF 150 1 <br />138 COATS 6 SF 150 1 <br />130 EXAM ROOM 176 SF 150 2 <br />129 EXAM ROOM 169 SF 150 2 <br />128 EXAM ROOM 168 SF 150 2 <br />127 EXAM ROOM 164 SF 150 2 <br />1/4" = 1'-0"1 EGRESS PLAN <br />3074 SF 97 <br />No. Description Date <br />1 PLAN CHECK 1 02/06/25 <br />2 PLAN CHECK 2 03/25/25
The URL can be used to link to this page
Your browser does not support the video tag.