Laserfiche WebLink
REFLECED CEILING PLAN LEGEND <br />CEILING TYPES <br />LIGHT FIXTURE TYPES <br />HIGH EFFICIENCY RECESSED DOWNLIGHT <br />CEILING DEVICES <br />DESIGNATES EXISTING TO REMAIN <br />DESIGNATES NEW <br />(E) <br />(N) <br />EXHAUST FAN PER MECHANICAL PLANS <br />1. REFLECTED CEILING PLAN GENERAL NOTES APPLY TO ALL REFLECTED CEILING PLAN SHEETS. <br />2. CEILING HEIGHTS ARE AS NOTED ON THE REFLECTED CEILING PLAN UNLESS NOTED <br />OTHERWISE. <br />3. ALL DIMENSIONS ON REFLECTED CEILING PLANS ARE ACTUAL AND ARE TO THE FACE OF <br />WALL FINISH UNLESS OTHERWISE NOTED. <br />4. CEILING HEIGHTS ARE OFF OF FLOOR ELEVATION, NOT FINISH FLOOR. <br />5. THE PATH OF EXIT TRAVEL TO AND WITHIN EXITS IN THIS BUILDING SHALL BE DENTIFIED BY EXIT <br />SIGNS CONFORMING TO THE REQUIREMENTS OF SECTION 1011 AND AS NOTED BELOW <br />(1011.1) <br />A. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH <br />B. EXITS SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE <br />DIRECTION... <br />6. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. INTERNALLY <br />ILLUMINATED EXIT SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SECTION 2702. <br />EXTERNALLY ILLUMINATED EXIT SIGNS SHALL COMPLY WITH THE GRAPHICS AND POWER <br />SOURCE REQUIREMENTS IN SECTIONS 1011.5.1 AND 1011.6, RESPECTIVELY. WHEN THE <br />FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN <br />INTENSITY OF NOT LESS THAN 5-FOOT-CANDLES ( 54 LUX). (1011.6.2, 1016.3) <br />7. 3. ANY TIME A BUILDING OR A PORTION OF A BUILDING IS OCCUPIED, THE MEANS OF <br />EGRESS SERVING THE OCCUPIED PORTION SHALL BE ILLUMINATED AT AN INTENSITY OF <br />NOT LESS THAN 1-FOOT-CANDLE (11 LUX) AT THE WALKING SURFACE LEVEL. <br />8. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY <br />THE PREMISE'S ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, <br />ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM <br />FOR THE FOLLOWING AREAS: <br />A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT <br />REQUIRED TWO OR MORE MEANS OF EGRESS. <br />B. CORRIDORS, EXIT ENCLOSURES, AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED <br />TO HAVE TWO OR MORE EXITS. <br />C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE <br />UNTIL EXIT DISCHARGE IS ACCOMPLISH FOR BUILDINGS REQUIRED TO HAVE TWO OR <br />MORE EXITS. <br />D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1022, IN BUILDINGS <br />REQUIRED TO HAVE TWO OR MORE EXITS. <br />E. EXTERIOR LANDINGS FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO <br />HAVE TWO OR MORE EXITS. <br />GWB, GYPSUM BOARD CEILING <br />ACT-1 <br />8' -6" <br />CEILING TYPE AND HEIGHT <br />ACT-1: 2' X 4' X 5/8" LAY-IN ACOUSTICAL CEILING TILE SYSTEM <br />NOTES: ARMSTRONG <br />OPEN CEILING TO DECK <br />RECESSED LED DOWNLIGHT <br />RECESSED 2X4 LED DIRECT/INDIRECT FIXTURE <br />PENDANT CYLINDER FIXTURE <br />REFLECED CEILING PLAN GENERAL NOTES <br />EXIT SIGN W/ BATTERY BACK-UP <br />EMERGENCY LIGHT 90 MIN. BAT. BACK UP <br />REFLECED CEILING PLAN KEYNOTES <br />OFFICE/IT <br />122 <br />PLAY AREA <br />121 <br />EXAM ROOM <br />136 <br />EXAM ROOM <br />135 <br />EXAM ROOM <br />134 <br />EXAM ROOM <br />133 <br />LOUNGE <br />132 <br />UTILITY <br />131 <br />WAITING AREA <br />120 <br />RECEPTION <br />125 <br />CORRIDOR <br />137 <br />LAB <br />126 <br />EXAM ROOM <br />130 <br />EXAM ROOM <br />129 <br />EXAM ROOM <br />128 <br />EXAM ROOM <br />127 <br />COATS <br />138 <br />TOILET <br />124 <br />TOILET <br />123 <br />JJJJ <br />J <br />J <br />J <br />J L-1 L-1 <br />L-1L-1 <br />L-1L-1 <br />L-1L-1 <br />L-1L-1 <br />L-1 L-1 <br />L-1L-1 <br />L-1 L-1 <br />L-1L-1 <br />L-1L-1 <br />L-1L-1 <br />L-1L-1 L-1L-1 <br />L-1 L-1 L-1 L-1 <br />L-1L-1L-1L-1 <br />L-1 L-1 L-1 <br />L-1L-1 <br />L-1 <br />L-1 <br />L-1 L-1 <br />L-1 <br />L-1 L-1 L-1 L-1 L-1 <br />L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 <br />L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 <br />L-2 L-2 <br />L-2 <br />40" <br />48 <br />" <br />24 <br />" <br />20"40"20" <br />24 <br />" <br />48 <br />" <br />8' - 0" <br />10' - 0" <br />8' - 0" <br />L-4 <br />L-4 <br />L-4 <br />L-4 <br />L-4 <br />405 <br />403 <br />404 <br />402 <br />409 <br />409 409 <br />406 <br />407 <br />407 <br />401 401 <br />410 412 413 <br />408 411 <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />4 <br />: <br />5 <br />2 <br /> <br />P <br />M <br />PROPOSED REFLECTED <br />CEILING PLAN <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />1/4" = 1'-0"1 PROPOSED REFLECTED CEILING PLAN <br />401 (N) GYP. BD. CEILING PER FINISH SCHEDULE, TYP. <br />402 (N) 2 x 4 SUSPENDED CEILING GRID & CEILING TILES, TYP. <br />403 (N) LIGHT FIXTURE PER LIGHT FIXTURE LEGEND, TYP. <br />404 (N) EMERGENCY EXIT SIGN W/ DIRECTIONAL ARROWS AND <br />BATTERY BACK-UP. <br />405 (N) EMERGENCY EXIT LIGHTING W/ BATTERY BACK-UP. <br />406 (N) J-BOX FOR OVERHEAD EXAM ROOM LIGHT VERIFY LOCATION <br />REQ'D. WITH MANUFACTURE'S SPECIFICATIONS, TYP. <br />407 3-WAY SWITCH TO TV AREA. <br />408 PROVIDE OCCUPANCY SENSORS WITH OUTO-OFF FEATURE, TYP. <br />409 EXHAUST PER MECHANICAL PLANS, TYP. <br />410 PROVIDE (N) CONCEALED FIRE SPRINKLERS W/ CAP TO MATCH <br />CEILING. PLANS FOR MODIFICATIONS TO FIRE PROTECTION <br />SYSTEMS SHALL BE SUBMITTED TO THE FIRE PROTECTION <br />DISTRICT UNDER SEPARATE PERMIT FOR REVIEW AND APPROVAL <br />PRIOR TO INSTALLATION OR WORK BEING STARTED. <br />411 PROVIDE (2) ROWS OF SOUND ATTENUATION BATT INSULATION <br />ABOVE SUSPENDED CEILING @ PERIMETER OF ALL EXAM ROOMS <br />& OFFICES TO REDUCE NOISE TRANSFER BETWEEN ROOMS, TYP. <br />412 G.C. TO PROVIDE CERTIFIED AIR BALANCE THROUGHOUT <br />413 N-LIGHT LIGHTING CONTROLS PER ELECTRICAL PLANS <br />No. Description Date