POWER/DATA PLAN LEGEND <br />POWER <br />SYMBOL DESCRIPTION <br />DUPLEX RECEPTACLE <br />QUAD. RECEPTACLE <br />JUNCTION BOX <br />DATA <br />SYMBOL DESCRIPTION <br />TELEPHONE & DATA OUTLET <br />DATA OUTLET <br />RECEPTABLE WITH GFCI @ 42" A.F.F. (U.O.N.) <br />1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE <br />CALIFORNIA ELECTRICAL CODE 9CEC0 AND ALL OTHER APPLICABLE LOCAL CODES <br />AND REGULATIONS INCLUDING OSHA. <br />2. PROVIDE AND INSTALL NEW BUILDING STANDARD TELEPHONE & ELECTRICAL <br />OUTLETS AS NOTED ON PLAN. <br />3. POWER & DATA SHOWN ON PLAN FOR LOCATION ONLY. SEE ELECTRICAL DRAWINGS <br />FOR ADDITIONAL INFORMATION. <br />4. PROVIDE CONDUIT AND WALL DEVICES FOR ALL AV, IT & SECURITY <br />INFRASTRUCTURE. <br />5. NO CORING SHALL BE DONE WITHOUT PRIOR NOTIFICATION AND COORDINATION <br />WITH THE OFFICE OF THE BUILDING. NO CORING THROUGH STRUCTURAL BEAMS AND <br />DUCTS. <br />6. COORDINATE WITH ALL OTHER SUBCONTRACTORS AS REQUIRED FOR INSTALLATION <br />OF MECHANICAL EQUIPMENT, EQUIPMENT SCHEDULE AND KEYLESS ENTRIES AS <br />REQUIRED AND WHERE OCCURS. <br />7. ALL ELECTRICAL OUTLETS WITHIN 5'-0" OF A WATER SOURCE SHALL BE G.F.I. <br />8. ALL ELECTRICAL OUTLETS AT COLUMNS TO BE EXTENDED TO FACE OF OF NEW <br />FURRED WALL. <br />9. ALL WALL OUTLETS & COVER PLATES TO HAVE WHITE FINISH. <br />10. ALL FLOOR CORE OUTLETS TO BE STAINLESS STEEL FINISH. <br />11. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED TO COMPLY WITH THEIR SPECIFIC <br />MANUFACTURER'S REQUIREMENTS. <br />12. IF ANY OUTLETS CANNOT BE INSTALLED AS NOTED OR AS SHOWN ON PLANS DUE TO <br />CONFLECT WITH STRUCTURAL, MECHANICAL OR ELECTRICAL BUILDING ELEMENTS, <br />CLARIFY WITH ARCHITECT BEFORE PROCEEDING. <br />13. SEE AV DRAWINGS FOR AV, TELECOM & SECURITY CONDUIT SIZING AND RUN <br />LOCATIONS. <br />14. LIGHTING FIXTURES ARE TO BE LOCATED AS REQUIRED ON THE JOB TO CLEAR <br />DUCTS,PIPING AND MECHANICAL EQUIPMENT. <br />15. CONDUIT RUNS SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC. ACTUAL FIELD <br />CONDITIONS PREVAIL. <br />16. EXPOSED CONDUITS TO BE RUN PARALLEL OR PERPINDICULAR TO WALLS, CEILINGS <br />AND FLOORS. <br />17. TEMPERATURE CONTROL WIRING SHALL BE FURNISHED AND INSTALLED BY <br />MECHANICAL TRADES. UNLESS OTHERWISE NOTED ON THE DRAWINGS. THIS <br />CONTRACTOR SHALL PROVIDE 12OV POWER WHERE REQUIRED. <br />18. LOCATIONS AND QUANTITY OF EXIT SIGNS AND EMERGENCY LIGHTS IS <br />APPROXIMATE. CONTRACTOR SHALL VERIFY LOCATION(S) AND QUANTITY WITH <br />LOCAL AUTHORITIES AND MAKE CORRECTIONS AT NO ADDITIONAL COST TO THE <br />OWNER. <br />POWER/DATA GENERAL NOTES <br />LOW VOLTAGE GENERAL NOTES <br />1. ALL LOW VOLTAGE ROUGH-IN WORK (CONDUIT, BOXES, MUD RINGS, ETC. BY <br />ELECTRICAL CONTRACTOR. <br />2. ALL LOW VOLTAGE CONDUITS SHALL BE 3/4" P.V.C. UNLESS OTHERWISE NOTED. <br />3. ALL BOX HEIGHTS ARE 18" A.F.F. TO CENTER UNLESS OTHERWISE NOTED. <br />4. ALL DATA AND TELEPHONE WIRING SHALL BE CAT5E OR CAT6 PLENUM RATED. <br />5. ALL SPEAKER WIRING SHALL BE 18/2 U.L.RATED FOR IN WALL USE. <br />6. ALL CABLE/SATELITE TV WIRING SHALL BE RG-6 U.L. RATED FOR IN WALL USE. <br />7. PULL 18" OF WIRE LENGTH THROUGH EACH J-BOX UNLESS NOTED OTHERWISE. <br />8. PROPERLY MARK WIRES AT EACH END WITH A PORT NUMBER AND ROOM LOCATION. <br />KEEP RECORD OF DESIGNATED PORT NUMBERS AND SUBMIT TO TENANT TO KEEP <br />FOR THEIR RECORDS. <br />9. VERIFY ALL REQUIREMENTS FOR IN WALL AND THROUGH CEILING WIRING WITH <br />LOCAL CODES AND AMMENDMENTS <br />10. ALL TERMINATIONS AND CONNECTIONS BY OTHERS. <br />11. EXCERSISE PROPER CARE WHEN PULLING AND SECURING WIRES TO ENSURE NO <br />KINKS OR BREAKS OCCUR. <br />12. ALL WIRING SHALL BE HOMERUNS. NO DAISY CHAINING ALLOWED <br />CEILING MOUNTED RECEPTACLE <br />DUPLEX / QUADRUPLEX FLOOR MOUNTEED <br />RECEPTABLE <br />DATA OUTLET FLOOR MOUNTED <br />J <br />POWER / DATA PLAN KEYNOTES <br />+48" <br />+48" GFI <br />+48" <br />+48" GFI <br />+48" <br />+48" GFI <br />+48" <br />+48" GFI <br />+4 <br />8 <br />" <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />I <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />I <br />+4 <br />8 <br />" <br />+4 <br />8 <br />" <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />I <br />+4 <br />8 <br />" <br /> <br />G <br />F <br />I <br />+4 <br />8 <br />" <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />TV <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />+4 <br />2 <br />" <br />G <br />F <br />I <br />J J <br />J J <br />J J <br />J <br />J <br />J <br />J <br />V/A <br />+3 <br />4 <br />" <br />G <br />F <br />I <br />PLAY AREA <br />121 <br />OFFICE/IT <br />122 <br />EXAM ROOM <br />136 <br />EXAM ROOM <br />135 <br />EXAM ROOM <br />134 <br />EXAM ROOM <br />133 <br />LOUNGE <br />132 <br />CORRIDOR <br />137 <br />RECEPTION <br />125 <br />WAITING AREA <br />120 <br />TOILET <br />124 <br />TOILET <br />123 <br />LAB <br />126 <br />UTILITY <br />131 <br />EXAM ROOM <br />130 <br />EXAM ROOM <br />129 <br />EXAM ROOM <br />128 <br />EXAM ROOM <br />127 <br />501501 <br />502 <br />TYP. <br />501 <br />501 <br />503 <br />502 <br />503 <br />TYP. <br />TYP. <br />TYP. <br />504 <br />505 506 <br />507 <br />507 <br />508 <br />509 <br />510 510 <br />511 <br />512 <br />TYP. <br />512 <br />TYP. <br />513 <br />TYP. <br />513 <br />TYP. <br />J <br />J <br />J <br />J <br />+3 <br />4 <br />" <br />G <br />F <br />I <br />J <br />J J J J <br />J <br />J <br />J <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />4 <br />: <br />5 <br />4 <br /> <br />P <br />M <br />PROPOSED <br />POWER/DATA PLAN <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />1/4" = 1'-0"1 PROPOSED POWER/DATA PLAN <br />501 PROVIDE MECHANICAL GROUND AT X-RAY EQUIPMENT. <br />502 PROVIDE TEMPER PROOF, HOSPITAL GRADE RECEPTACLES AT <br />ALL EXAM ROOMS. <br />503 VERIFY ALL ELECTRICAL REQ'D FOR DENTAL EQUIPMET WITH <br />SUPPLIER. <br />504 ALL RECEPTACLES IN LAB SHALL BE GFI & 42" AFF. ELEC. VERIFY <br />EQUIP. LAYOUT & REQUIREMENTS PRIOR TO ROUGH-IN. <br />505 ELECTRICAL & GENERAL CONTRACTOR SHALL VERIFY FINAL <br />LAYOUT OF PLAY AREA WITH TENANT. <br />506 PROVIDE TAMPER RESISTANT RECEPTACLES IN PLAY AREA, <br />OFFICES, CORRIDORS, WAITING ROOMS AND SIMILAR AREAS, IN <br />COMPLIANCE WITH CEC 406.12(5). <br />507 @ 12" BELOW FINISH CLG. FOR TV. <br />508 @ 18" BELOW FINISH CLG. FOR TV. <br />509 DATA/COMM HUB SHOWN IN THIS LOCATION. VERIFY FINAL <br />LOCATION WITH TENANT PRIOR TO ROUGH IN. <br />510 PROVIDE POWER FOR HAND DRYER, GFI BREAKER, VERIFY <br />LOCATION W/ MANUF. WORLD DRYER NOVA 1 <br />511 PROVIDE REMOTE PANELS FOR AIR/VAC FURNISHED BY EQUIP. <br />SUPPLIER INSTALED BY ELEC. GC. <br />512 GROUNDING OF RECEPTACLES AND FIXED ELECTRICAL <br />EQUIPMENT IN PATIENT CARE AREAS. WIRING IN PATIENT CARE <br />AREAS SHALL COMPLY WITH THE FOLLOWING:(A) ALL BRANCH <br />CIRCUITS SERVING PATIENT CARE AREAS SHALL BE PROVIDED <br />WITH AN EFFECTIVE GROUND-FAULT CURRENT PATH BY <br />INSTALLATION IN A METAL RACEWAY SYSTEM, OR A CABLE <br />HAVING A METALLIC ARMOR OR SHEATH ASSEMBLY. THE METAL <br />RACEWAY SYSTEM, OR METALLIC CABLE ARMOR, OR SHEATH <br />ASSEMBLY SHALL ITSELF QUALIFY AS AN EQUIPMENT <br />GROUNDING CONDUCTOR IN ACCORDANCE WITH THE CEC. (B) <br />THE GROUNDING TERMINALS OF ALL RECEPTACLES AND ALL <br />NON-CURRENT-CARRYING CONDUCTIVE SURFACES OF FIXED <br />ELECTRICAL EQUIPMENT LIKELY TO BECOME ENERGIZED THAT <br />ARE SUBJECT TO PERSONAL CONTACT, OPERATING AT OVER 100 <br />VOLTS, SHALL BE CONNECTED TO AN INSULATED COPPER <br />EQUIPMENT GROUNDING CONDUCTOR. THE EQUIPMENT <br />GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH <br />THE CEC AND INSTALLED IN METAL RACEWAYS OR AS A PART OF <br />LISTED CABLES HAVING A METALLIC ARMOR OR SHEATH <br />ASSEMBLY WITH THE BRANCH-CIRCUIT CONDUCTORS SUPPLYING <br />THESE RECEPTACLES OR FIXED EQUIPMENT. EXCEPTION NO. 1: <br />METAL FACEPLATES SHALL BE PERMITTED TO BE CONNECTED TO <br />THE EQUIPMENT GROUNDING CONDUCTOR BY MEANS OF A <br />METAL MOUNTING SCREW(S) SECURING THE FACEPLATE TO A <br />GROUNDED OUTLET BOX OR GROUNDED WIRING DEVICE. <br />EXCEPTION NO. 2:LUMINAIRES MORE THAN 2.3 M (7 1/2 FT) ABOVE <br />THE FLOOR AND SWITCHES LOCATED OUTSIDE OF THE PATIENT <br />CARE VICINITY SHALL BE PERMITTED TO BE CONNECTED TO A <br />STANDARD EQUIPMENT GROUNDING RETURN PATH. <br />513 PVC COATED METAL RIGID CONDUIT UNDER CABINET. RUN <br />BELOW SLAB AND UP THROUGH WALL AS SHOWN. STUB ABOVE <br />FINISH CEILING (TYPICAL AT ALL EXAM ROOMS). <br />No. Description Date <br />1 PLAN CHECK 1 02/06/25