Laserfiche WebLink
ACOUSTICAL <br />CEILING TILE <br />RECESSED LIGHT <br />SEE ELECT. DWGS <br />TWO (2) 12 GA. SLACK SAFETY <br />WIRES ATTACHED TO FIXTURE <br />AT DIAGONAL CORNERS AND <br />ANCHORED TO STRUCTURE <br />ABOVE <br />OR 1/4 OF THE LENGTH OF <br />THE END RUNNER <br />WHICHEVER IS LESS <br />WALL TYPE <br />PER PLANS <br />MIN. (3) TURNS IN <br />1-1/2" <br />RUNNER <br />ACOUSTIC <br />CEILING TILE <br />POP RIVET <br />WALL MOLDING <br />BACKING PER MANF. RECOMMENDATION <br />8" MAX. <br />ACOUSTIC CEILING TILE <br />T-BAR RUNNER <br />HANGER WIRE <br />PROVIDE #12 WIRE <br />BRACING WITHIN 2" OF <br />INTERS. AT EA. 96 SQ. FT. <br />OF CLG. AREA <br />#12 GA. WIRE TIES @ 48" OC <br />VERTICAL (1:6 SLANT MAX) <br />PROVIDE 1 TIE @ 8" MAX <br />FROM ENDS MAX. <br />2" <br />STRAP BLOCKING <br />MIN. 16 MSG STEEL <br />STUDS @ 24" O.C. <br />5/8" GYPSUM BOARD <br />PERPENDICULAR TO <br />STUD FRAMING <br />CONNECTION <br />CORROSION-RESISTANT <br />TREATED FASTENERS AT 12" <br />O.C. MAX <br />NOTE: <br />STUD CONNECTION FASTENS THROUGH MAX. 2 LAYERS OF <br />GYPSUM BOARD <br />FOR MAX OPENING <br />IN CEILING. <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />5 <br />: <br />0 <br />8 <br /> <br />P <br />M <br />CEILING DETALS <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />No. Description Date <br />1 PLAN CHECK 1 02/06/25 <br />2 PLAN CHECK 2 03/25/25 <br />3" = 1'-0"1 <br />RECESSED LIGHT IN SUSPENDED <br />CEILING TILE <br />3" = 1'-0"2 <br />SUSPENDED CEILING AT PERIMETER <br />WALL <br />3" = 1'-0"3 SUSPENDED CEILING TILE SYSTEM <br />3" = 1'-0"4 <br />SUSPENDED T-BAR GRID CEILING <br />DETAIL <br />3" = 1'-0"66 <br />SUSPENDED T-BAR GRID CEILING <br />BRACING DETAIL <br />3" = 1'-0"5 COMPRESSION STUT DETAIL <br />1" = 1'-0"6 <br />FRAMED GYPSUM BOARD CEILING <br />ASSEMBLY <br />A-4.11 <br />5 <br />5/A-4.112 <br />2