CALL TOLL FREE 1 (800) 227-2600 <br />TWO WORKING DAYS BEFORE YOU DIG <br />REVISIONS <br />NO.DATE DESCRIPTION NO.DATE DESCRIPTION <br />CONTRACTOR: <br />CORONA CONSTRUCTION CO. <br />615 E. ALLEN AVE. <br />SAN DIMAS, CA 91773 <br />PHONE: 626-926-7487 <br />CA. LIC. #797455 CLASS A-B-HAZ C10 <br />EXPIRES 07/31/2025 <br />ELECTRICAL NOTES <br />SITE ADDRESS: <br />UNITED PACIFIC #5669 <br />1913 WEST EDINGER AVE. <br />SANTA ANA, CA 92704 <br />SCALE: <br />DRAWN BY: <br />DATE: <br />JOB NO. <br />DRAWING NO. <br />CHECKED BY: <br />AS NOTED <br />ETHAN BUI <br />7/19/2023 <br />5669 <br />F6 <br />ALVARO CORONA <br />SHEET <br />F6 <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />L <br />ICENSED CONTRACTOR <br />STATE OF CAL IFORNIA <br />CORONA CONSTRUCTION CO. <br />797455 <br />EXPIRES 07/31/2025 <br />ELECTRICAL SPECIFICATIONS <br />PART 1 - GENERAL <br />1.01 SCOPE OF WORK: <br />FURNISH AND INSTALL ALL MATERIALS AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENCE AND <br />SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND/OR SPECIFIED HEREIN. ALSO INCLUDE ALL <br />OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED, BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION <br />INCLUDING ALL ACCESSORIES AND APPURTENANCES REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWINGS AND <br />SPECIFICATIONS, THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. <br />1.02 REGULATORY REQUIREMENTS: <br />CODE COMPLIANCE IS MANDATORY NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMIT WORK NOT CONFORMING TO THESE CODES. <br />WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND <br />MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: <br /> 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSHA). <br /> 2. NFPA 170: NATIONAL ELECTRIC CODE (NEC). <br /> 3. NFPA #101: LIFE SAFETY CODE. <br /> 4. STATE FIRE MARSHAL. <br /> 5. LOCAL UTILITIES COMPANIES. <br /> 6. LANDLORD REQUIREMENTS. <br />1.03 LICENSE, FEES AND PERMITS: <br />ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMIT AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION <br />AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. <br />1.04 SAFETY AND INDEMNITY: <br />THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS <br />AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING HOURS, NO ACT. SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, AND ENGINEERS OR THEIR <br />CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE <br />CONSTRUCTION SITE. <br />1.05 DRAWINGS AND SPECIFICATIONS: <br />ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOWN <br />ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL <br />ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENT <br />SHALL BE GOVERNED BY CONDITIONS OF THIS JOB. CONSULT ALL OTHER DRAWINGS IN PREPARATION OF THE BID. EXTRA LENGTHS OF WIRING <br />OR ADDITION OF PULL OR JUNCTION BOXES, ETC., NECESSITATE BY SUCH CONDITIONS SHALL BE INCLUDED IN THE BID. <br />1.06 CONDITIONS AT SITE: <br />VISIT SITE OF THE WORK, COMPARE IT WITH THE DRAWINGS AND SPECIFICATIONS AS TO THE CONDITIONS UNDER WHICH WORK IS TO BE <br />PERFORMED, ASCERTAIN AND CHECK ALL CONDITIONS AND ELEVATIONS AND TAKE ALL MEASUREMENTS WHICH MAY AFFECT THE WORK NO <br />ALLOWANCE SHALL SUBSEQUENTLY BE MADE FOR ANY EXTRA EXPENSE OR CLAIMS DUE TO FAILURE OR NEGLECT UNDER THIS REQUIREMENT <br />TO MAKE SUCH EXAMINATION, INCLUDING EXAMINATION OF RESTRICTED WORKING CONDITIONS OR SUCH OTHER DIFFICULTIES VISUALLY <br />OBSERVED DURING SITE VISIT. CONTRACTOR IS RESPONSIBLE FOR BECOMING COMPLETELY FAMILIAR WITH THE ARCHITECTURAL TOOLS AND <br />MATERIALS REQUIRED TO PRODUCE A COMPLETELY CONCEALED INSTALLATION AS INDICATED ON THE PLANS, SPECIFICATIONS, AND REQUIRED <br />BY THE CODE. <br />1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: <br />ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF THE WORK. <br />1.08 SHOP DRAWINGS AND MATERIALS LISTS: <br />SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LIST, AS NOTED BELOW, FOR <br />REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. <br />SUBMITTALS REQUIRED AS FOLLOWS: <br /> 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. <br /> 2. SWITCHBOARD & ENCLOSURES FOR UTILITY COMPANY METERING. <br /> 3. MAIN FUSED DISCONNECT SWITCH. <br /> 4. PANEL BOARDS. <br /> 5. DISCONNECT SWITCHES. <br /> 6. LIGHTING FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. <br />1.09 SUBSTITUTIONS: <br />ONE OR MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, <br />FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED <br />PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE <br />ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION IS PERMITTED. NO <br />WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. <br />THE OWNER IS THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM IS PERMITTED, AND ANY <br />RE-DESIGN EFFORT IS THEREBY NECESSITATED. THE REQUIRED RE-DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. <br />1.10 COORDINATION: <br />COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH-IN AND CONNECTION FOR EQUIPMENT <br />FURNISHED UNDER OTHER TRADES THAT REQUIRE ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES OF THE REQUIRED <br />ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPLIANCE. VERIFY EQUIPMENT <br />DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING <br />WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, <br />WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. <br />1.11 CUTTING AND PATCHING: <br />ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION IS INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND <br />OTHER TRADES IS IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER <br />HOLES, SUPPORTS, ETC. <br />1.12 ACCEPTANCE DEMONSTRATION: <br />UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR THE OWNER THE <br />OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. <br />PROPERLY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S <br />REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND/OR TEST TIME <br />SWITCHES PROGRAMMING. <br />1.13 RECORD DRAWINGS, EQUIPMENT DATA: <br />MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH "AS-BUILT" INFORMATION AS FEEDER AND SERVICE <br />ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION DELIVER COMPLETED <br />DRAWINGS TO THE OWNER. SUBMIT TO THE OWNER'S REPRESENTATIVE A SET OF "AS BUILT" DRAWINGS IN VELLUM AND CAD FILE. AS BUILT <br />COMMENTS SHALL BE WRITTEN IN A LEGIBLE MANNER IN THE SAME STYLE AS THE CONTRACT DOCUMENTS. ALSO SUBMIT THREE COPIES OF DATA <br />SHEETS OR OTHER CURRENT MANUFACTURERS' PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT <br />INCLUDING AT LEAST THESE DATA: <br /> 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. <br /> 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. <br /> 3. USER'S MANUAL AND OPERATION INSTRUCTIONS. <br /> 4. MANUFACTURER'S WARRANTY. <br />1.14 CLEAN-UP: <br />RID THE PREMISES OF SCARP MATERIALS. TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE <br />BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. <br />1.15 GUARANTEE: <br />GUARANTEE THE INSTALLATION IS FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF <br />CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHARGE. <br />1.16 TEMPORARY SERVICES <br />PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE <br />PREMISES. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: <br /> 1. THREE 20-AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA <br /> REQUIREMENTS. <br /> 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT <br /> MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH <br /> ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN <br /> ROWS TO SIXTEEN FEET OR LESS. <br /> 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. <br /> 4. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT <br /> FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR <br /> REMOVAL OF TEMPORARY SERVICE PROVISIONS. <br />3.03 INSTALLATION OF WIRES: <br /> A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS <br /> BEEN COMPLETED. <br /> B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHEN REQUIRED SHALL BE <br /> MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8” OF CORRECTLY <br /> COLOR-CODED TAILS LEFT IN THE BOX. <br /> C. SPLICES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. <br /> D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY <br /> MANUFACTURE. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE IS NOT <br /> APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. <br /> E. PROVED BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. <br /> F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT <br /> MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. <br />3.04 WIRE COLOR CODE: <br />COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12AWG THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF <br />ANY SIZE IN CABLE ASSEMBLES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: <br />VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND <br /> 120/208V BLACK RED BLUE WHITE GREEN <br /> 277/480V BROWN ORANGE YELLOW GRAY GREEN <br />3.05 IDENTIFICATION: <br /> A. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND <br /> CIRCUIT NUMBER TO WHICH THE DEVISE IS CONNECTED. <br /> B. EACH PANEL BOARD SHALL CONTAIN A METAL-FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. <br /> C. PANEL BOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANEL BOARD SCHEDULES FOR ALL PANEL <br /> BOARDS. <br />3.06 REMODELING WORK <br /> A. EXISTING ELECTRICAL WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED DUE TO CONSTRUCTION <br /> CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO OPERATING CONDITION. WHERE CONSTRUCTION CHANGES REQUIRE, <br /> OUTLETS AND CONDUIT RUNS SHALL BE RELOCATED. EXTEND CONDUITS AND PULL IN NEW WIRING OR INSTALL JUNCTION BOXES AND <br /> SPLICE IN NEW WIRING. <br /> B. OUTLETS FROM WHICH FIXTURES, SWITCHES, RECEPTACLES, AND/OR OTHER ELECTRICAL DEVICES ARE REMOVED AND WHICH ARE NOT <br /> REPLACES OR REUSED SHALL BE REMOVED, WHERE OUTLETS BOXES, ETC, ARE COMPLETELY REMOVES, THE CONTRACTOR SHALL CUT <br /> OFF CONDUITS AND REMOVE WIRING. <br /> C. WHERE CONDUITS EXTENDING THROUGH FLOORS ARE TO BE ABANDONED, THE CONTRACTOR SHALL CUT AND CAP OR <br /> D. WHERE EXISTING CONDUIT IS TO BE ABANDONED, THE CONDUIT SHALL BE REMOVED IF IT IS EXPOSED, IN A CRAWL SPACE PLUG <br /> CONDUIT, AND THE CONDUIT SHALL NOT PROTRUDE ABOVE THE FLOOR. OR IN ACCESSIBLE CEILING. WHERE IT IS IMPOSSIBLE TO <br />REMOVE THE CONDUIT, IT SHALL BE CUT OFF AND CAPPED OR PLUGGED. <br /> E. REMOVE ALL EXISTING WIRING NOT REUSED OR REQUIRED TO MAINTAIN CONTINUITY TO CIRCUITS TO REMAIN. <br /> F. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE PROPER RESTORATION OF ALL EXISTING SURFACES REQUIRING <br /> PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIRS DUE TO THE INSTALLATION OF ELECTRICAL WORK UNDER THE TERMS OF <br /> THIS SPECIFICATION. CLOSE ALL OPENING. REPAIR ALL SURFACES. ETC. AS REQUIRED. <br /> G. MAINTAIN CIRCUIT CONTINUITY TO AREAS OUTSIDE OF THIS WORK. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED TO <br /> MAINTAIN CONTINUITY AND MAINTAIN AREA AS EXISTING. <br />3.07 GROUNDING: <br /> A. ELECTRICAL SERVICES AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH NEC <br /> ARTICLE 250-3 TO 250-26, INCLUSIVE. <br /> B. GROUND NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR <br /> CABLE TRAYS TO PROVIDE A LOW IMPENDENCE PATH FOR LINE-TO-GROUND FAULT CURRENT AND TO BAND ALL NON-CURRENT <br /> CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS <br /> SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL <br /> CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250-95 UNLESS LARGER <br /> CONDUCTORS ARE SHOWN ON DRAWINGS. <br /> C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER <br /> SIZES, BLACK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVISE ENCLOSURE. <br />HAZARDOUS LOCATION NOTES <br />GENERAL INSTALLATION REQUIREMENTS/FUEL EQUIPMENT COMPATIBILITY: <br /> 1. EARTH GROUND IS REQUIRED FOR PROPER EQUIPMENT OPERATION. EACH FUEL-ASSOCIATED DEVICE IS TO BE CONNECTED TO THE <br /> GROUND BUS OF THE MAIN POWER PANEL WITH A GREEN INSULATED WIRE TO PROVIDE A SINGLE REFERENCE POINT FOR EARTH <br /> GROUND. THE GROUND BUS BAR WILL THEN BE CONNECTED TO A COPPER CLAD GROUND ROD DRIVEN NO LESS THAN 9 FT. INTO THE <br /> GROUND. GROUNDING SHALL MEET CEC SECTION 250 REQUIREMENTS. <br /> 2. ALL FUEL EQUIPMENT (I.E. DISPENSERS, MONITORING SYSTEM. POS. AND STPS) MUST BE CONNECTED TO THE SAME ELECTRICAL PHASE. <br /> 3. EQUIPMENT WHICH COULD POTENTIALLY CREATE ELECTRICAL NOISE OR POWER SURGES (E.G. COOLERS, COMPRESSORS. FLUORESCENT <br /> LIGHTING, ETC.) SHALL NOT SHARE A CIRCUIT WITH POS EQUIPMENT. <br /> 4. SUBMERSIBLE TURBINE PUMPS (STPS). <br /> A. STP CONDUIT SHALL BE PVC COATED RIGID. STPS SHALL NOT SHARE A CIRCUIT WITH PIC OR POS EQUIPMENT. STP WIRING SHALL NOT <br /> BE ROUTED THROUGH THE SAME RACEWAY AS THE PIC COMMUNICATION WIRES. <br /> B. VARIABLE SPEED STP CONTROLLERS (I.E. RED JACKET OR FE PETRO) SHALL BE INSTALLED A MINIMUM OF 3 FT. FROM THE SAME <br /> MODULE. <br /> HAZARDOUS LOCATIONS SPECIFICATIONS: <br /> A. PROVIDE EXPLOSION PROOF JUNCTION BOX AND SEAL OFF FITTINGS PER ARTICLES 514 OF THE CEC FOR HAZARDOUS LOCATIONS. <br /> B. ALL CONDUIT AND WIRING TO FUEL DISPENSERS AND SUBMERSIBLE PUMPS SHALL BE INSTALLED AND USED IN ACCORDANCE WITH <br /> FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE NFPA 30 AND APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE CALIFORNIA <br /> ELECTRICAL CODE (CEC) ARTICLE 514. “MOTOR FUEL DISPENSING FACILITIES,” INCLUDING THE FOLLOWING: PROVIDE EXPLOSION <br /> PROOF/SEAL-OFF FITTINGS ON ALL POWER SUPPLY LINES LOCATED AT FUEL DISPENSERS, SUBMERSIBLE PUMPS AND ANY OTHER <br /> ELECTRICAL EQUIPMENT LOCATED IN A 20' RADIUS OF THE GASOLINE FUEL DISPENSER ISLAND. AN AREA PER FIGURE 5143 OF THE CEC <br /> IS DEFINED AS A HAZARDOUS LOCATION WITHIN A 20' RADIUS FROM THE END OF EACH DISPENSER ALL ELECTRICAL EQUIPMENT AND <br /> WIRING WITHIN THIS AREA SHALL BE PER CEC 514. <br /> C. AN APPROVED SEAL (EXPLOSION PROOF/SEAL-OFF FITTING) SHALL BE PROVIDED IN EACH CONDUIT RUN ENTERING OR LEAVING A <br /> DISPENSER OR ANY CAVITIES OR ENCLOSURES IN DIRECT COMMUNICATION THEREWITH. THE SEALING FITTING SHALL BE THE FIRST <br /> FITTING AFTER THE CONDUIT EMERGES FROM THE EARTH OR CONCRETE. ADDITIONAL SEAL SHALL BE PROVIDED AT BOUNDARIES IN <br /> ACCORDANCE WITH CEC SECTION 501.5 (A)(4) AND 501.5(BX2) APPLYING TO BOTH HORIZONTAL AS WELL AS VERTICAL BOUNDARIES <br /> OF CLASS I LOCATIONS. <br /> D. PROVIDE EXPLOSION PROOF/SEAL·OFF FITTING AT THE POINT OF CONDUIT STUB-UP ENTRANCE (AT PANEL BOARD) INTO THE SERVICE <br /> BUILDING FOR ALL POWER SUPPLY CONDUITS TO FUEL DISPENSERS, SUBMERSIBLE PUMPS AND OTHER ELECTRICAL EQUIPMENT <br /> LOCATED IN THE ABOVE DEFINED HAZARDOUS LOCATIONS. <br /> E. ALL BELOW GRADE CONDUIT RUNNING THROUGH (ENTERING OR LEAVING - THEN THE ENTIRE CONDUIT RUN SHALL BE RGS) THE <br /> CLASS I DIVISION 1 HAZARDOUS LOCATION AS DESCRIBED ABOVE AND AS DEFINED PER CEC ARTICLE 514 SHALL BE RGS. RIGID <br /> NON-METALLIC CONDUIT (PVC) MAY ONLY BE USED AS LONG AS THE PROVISIONS OF CEC ARTICLE 514.8. EXCEPTION NO.2 ARE <br /> STRICTLY ADHERED TO INCLUDING THE REQUIREMENTS FOR AN EQUIPMENT GROUNDING CONDUCTOR IN THE RIGID NON-METALLIC <br /> CONDUIT AND THE EQUIPMENT GROUNDING CONDUCTOR MUST BE BONDED TO THE EXPLOSION-PROOF RACEWAY SYSTEM INSIDE <br /> THE DISPENSER (THIS MAY BE ACCOMPLISHED BY TERMINATING THE EQUIPMENT GROUNDING CONDUCTOR ON THE GROUND <br /> SCREW PROVIDED IN THE JUNCTION BOX). WHERE RIGID NON-METALLIC CONDUIT IS USED IT SHALL BE USED FOR THE LAST 2 FEET OF <br /> THE UNDERGROUND RUN TO EMERGENCE OR POINT OF CONNECTION TO THE ABOVE GROUND RACEWAY. <br /> F. EACH CIRCUIT LEADING TO OR THROUGH A DISPENSING PUMP SHALL BE PROVIDED WITH A SWITCH TO DISCONNECT <br /> SIMULTANEOUSLY FROM THE SOURCE OF SUPPLY ALL AND CONDUCTORS OF THE CIRCUIT INCLUDING THE GROUNDED CONDUCTOR. <br /> G. THE METAL PORTION OF DISPENSING PUMPS, METAL RACEWAYS AND ALL NON-CURRENTCARAYING METAL PARTS OF ELECTRIC <br /> EQUIPMENT, REGARDLESS OF VOLTAGE, SHALL BE GROUNDED AS PROVIDED IN CEC ARTICLE 250. <br /> ELECTRICAL EQUIPMENT, REGARDLESS OF VOLTAGE, SHALL BE GROUNDED AS PROVIDED IN CEC ARTICLE 250. <br /> PART 2 - PRODUCTS <br />2.01 MATERIAL APPROVAL <br />ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITER'S LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING <br />STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN <br />ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. <br />2.02 CONDUITS AND OTHER RACEWAYS: <br /> A. ALL POWER CONDUITS TO BE 3/4" PVC COATED. <br /> B. LOW VOLTAGE CONDUITS TO BE 3/4" PVC WITH PVC COATED RIGID ENDS AS REQUIRED IN HAZARDOUS AREAS UNLESS NOTED <br />OTHERWISE. <br /> C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO-GALVANIZED. <br /> D. WIREWAY: CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. <br /> E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT <br /> CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND <br /> OUTDOORS. <br />2.03 WIRES AND CABLES: <br /> A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: <br /> 1. CONDUCTOR: MINIMUM SIZE #12 AWG. <br /> A. #12 AND #10 AWG SOLID COPPER. <br /> B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. <br /> 2. INSULATION TYPE: <br /> A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THHN FOR DRY LOCATIONS. <br /> B. #1/0 THROUGH #4/0 AWG: XHHW (55 MILS). <br /> C. #250 MCM AND LARGER: XHHW (65 MILS). <br /> D. GROUNDING WIRE: TW. <br /> B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: <br /> 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. <br /> 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #18 AWG MINIMUM, WITH THWN INSULATION FOR <br /> UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. <br /> C. ACCEPTABLE PRODUCTS: GENERAL ELECTRIC. ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING <br /> APPLICABLE IPCEA STANDARDS. <br />2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: <br /> A. OUTLET BOXES. 4” SQUARE X 1-1/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO-TYPE WITH PLASTER RING AND COVER FOR <br /> GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR <br /> LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). <br /> B. JUNCTION BOXES (FLOOR BOX NOT INCLUDED) SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE-GAUGE STEEL IN LARGER <br /> SIZES WITH SURFACE OR FLUSH-TYPE SCREW-MOUNTED TRIMCOVERS, BOTH BOXES AND COVERS INHIBITOR-PRIMED AND POINTED <br /> INSIDE OUT. <br /> C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. <br /> D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN <br /> 4-11/16" SQUARE X 2-1/8” DEEP WITH SINGLE-GONG RING AND SIERRA #S-754N SPLIT PLATE BUSHING. <br />2.05 WIRING DEVICES AND PLATES: <br />UNLESS OTHERWISE INDICATED, ALL WIRING DEVICES AND COVER PLATES SHALL BE FURNISHED AND INSTALLED IN COLOR TO MATCH FINISH <br />SURFACE WHERE IT IS LOCATED ON, IE, DARK BROWN, BEIGE, WHITE OR STAINLESS STEEL. <br />2.06 CONDUIT HANGERS: <br />FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR <br />POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM <br />REFLECTION NOT GREATER THAN 1/8”. <br />2.07 WIRE CONNECTORS: <br />FOR WIRE SIZES #8 AWG AND SMALLER: INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C, 600V, FOR BUILDING WIRING <br />AND 1000V IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER: T & B OR EQUIVALENT COMPRESSION TYPE <br />WITH 3M #33+ OR PLYMOUTH "SLIPKNOT GREY" TAPE INSULATION. <br />2.08 PANEL BOARDS: <br /> A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL <br /> BE OF COLD-ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS <br />LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20" <br />FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GREY ENAMEL SUITABLE FOR OVERPAINTING IT. <br /> B. CIRCUIT BREAKERS: SHALL BE QUICK-MAKE, QUICK-BREAK, MOLDED CASE TYPE: <br /> 1. 120/240 VOLT PANELS. SHALL BE GENERAL ELECTRIC TYPE “Q” LINE. BOLT-ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING <br /> CAPACITY AS SHOWN. <br /> 2. PROVIDE MULTI-POLE UNITS WITH COMMON TRIP ELEMENT. <br /> 3. CIRCUIT BREAKERS USED ON "ON-OFF" CONTROL OF FLUORESCENT LIGHTING (PANEL BOARD SWITCHING) SHALL BE UNDERWRITERS' <br /> LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. <br /> C. IDENTIFICATION. PROVIDE SCREWED-ON (NO ADHESIVES) BAKELITE OR PHOTO-ETCHED METALLIC NAMEPLATE IDENTIFICATION ON <br />OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE AND PHASE IN MINIMUM 1/8" HIGH LETTERS. EACH PANEL SHALL <br />CONTAIN A METAL-FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. <br /> D. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. <br />2.09 MISCELLANEOUS MATERIALS: <br /> A. SAFETY SWITCHES HEAVY DUTY TYPE, 480V OR 240V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON-FUSED AS REQUIRED. MOUNT <br />IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR WESTINGHOUSE. <br />PART 3 - EXECUTION <br />3.01 WIRING METHODS: <br /> A. INSTALL ALL WIRING IN RACEWAY. OR USE MC GABLE WHERE APPROVED BY ALL APPLICABLE CODES AND REGULATIONS. CONDUIT <br /> SHALL BE RIGID STEEL, IMC OR EMC AS FOLLOWS: <br /> 1. ABOVE GROUND: USE RIGID STEEL, IMC OR EMT. <br /> A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. <br /> B. LOCATIONS SUBJECT TO MECHANICAL INJURY RIGID STEEL OR IMC ONLY. <br /> C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMT, IMC, OR RIGID STEEL CONDUIT. <br /> 2. UNDERGROUND: USE RIGID STEEL <br /> B. USE FLEXIBLE CONDUITS OR MC CABLE IN THE FOLLOWING APPLICATIONS: <br /> 1. FINAL CONNECTIONS TO MOTOR. <br /> 2. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. <br /> 3. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. <br /> 4. INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES (NOT TO INCLUDE HOMERUN FROM FIXTURE OR DEVICE TO PANEL BOARD, <br /> WHICH MUST BE RIGID). <br /> 5. FINAL CONNECTIONS WHERE RIGID CONDUIT IS NOT PRACTICAL. <br /> 6. IN WALLS (FOR LIGHT SWITCHES AND 120V POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). <br /> C. FLEXIBLE METALLIC CONDUIT OR MC CABLE MUST BE THE SAME SIZE AS THE RIGID CONDUIT TO WHICH IT IS CONNECTED. <br /> D. THE CONNECTION TO OUTDOOR EQUIPMENT MUST BE WEATHERPROOF. I.E. LIQUID TIGHT OR SEAL TIGHT. <br /> E. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES IF <br /> APPROVED BY ALL APPLICABLE CODES MINIMUM SIZE FOR ALL OTHER LOCATIONS SHALL BE 3/4" IF HVAC CONTROL WIRING IS <br /> REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A 3/4" MINIMUM, UNLESS OTHERWISE NOTED ON DRAWINGS. ALL IN/UNDER FLOOR <br /> CONDUITS SHALL BE 3/4" MINIMUM SIZE. <br />3.02 INSTALLATION OF CONDUITS: <br /> A. GENERAL: <br /> 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. <br /> 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS AND BEAMS. <br /> 3. CONDUITS ABOVE CEILINGS SHALL NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. <br /> 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS <br /> WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. <br /> B. CONDUIT SUPPORTS: <br /> 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE <br /> NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS <br /> FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURES AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY <br /> CONDUIT TO MECHANICAL DUCTS AND PIPES. <br /> 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING. SUPPORT WIRES WITH CADDY CLIPS <br /> ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT IS PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG <br /> SUCH CONDUIT SO AS NOT TO AFFECT LEVEL OF CEILING OR LIFTING TILES. <br /> 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT IS NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A <br /> LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FOR FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO <br /> MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURES. <br /> C. CONDUIT PENETRATION: <br /> 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH <br /> FIRE RETARDANT SEALANT SPECIFIED HEREIN. <br /> 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF ORA EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS <br /> ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. <br /> 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL: INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS <br /> DETAILED ON THE DRAWINGS. <br /> 4. PENETRATING NON-FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER <br /> PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH IS APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH <br /> ESCUTCHEONS, ONE ON EACH SIDE OF WALL. <br /> 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON <br /> FOR EACH CONDUIT BELOW CEILING. <br />CEC TABLE 514.3 (B)(1) - CLASS II, GROUP D LOCATIONS <br />LOCATION UNDERGROUND TANK DIVISION EXTEND OF CLASSIFIED LOCATION <br />FILL OPENING DIV.1 ANY PIT, BOX OR SPACE BELOW GRADE LEVEL. ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED <br />LOCATION. <br />DIV.2 UP TO 18 IN. ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FT. FROM A <br />VENT -DISCHARGING UPWARD DIV.1 WITHIN 3 FT OF OPEN END VENT. EXTENDING IN ALL DIRECTIONS <br />DISPENSING DEVICE DIV.2 SPACE BETWEEN 3 FT. AND 5 FT. OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. <br />PITS DIV.1 ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. <br />DISPENSER SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN <br />"POWER OPERATED DISPENSING DEVISED FOR PETROLEUM PRODUCTS". ANSI/UL 67-1990 <br />DIV.2 WITHIN 18 IN, HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT <br />PORTION OF THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. <br />OUTDOOR DIV.2 UP TO 18 IN. ABOVE GRADE LEVEL WITHIN 20 FT. HORIZONTALLY OF ANY EDGE OF ENCLOSURE. <br />REMOTE PUMP-OUTDOOR DIV.1 FROM ANY EDGE OF PUMP. <br />DIV.2 WITHIN 3 FT. OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP TO 1 BIN. ABOVE <br />GRADE LEVEL WITHIN 10 FT. HORIZONTALLY FROM ANY EDGE OF PUMP. <br />SIGNED 5/14/24 <br />1913 W Edinger Ave - <br />101118671 & 201824107/2/2024