GASOLINE GASOLINE GASOLINE GASOLINE GASOLINE GASOLINE+DIESEL <br />CALL TOLL FREE 1 (800) 227-2600 <br />TWO WORKING DAYS BEFORE YOU DIG <br />REVISIONS <br />NO.DATE DESCRIPTION NO.DATE DESCRIPTION <br />CONTRACTOR: <br />CORONA CONSTRUCTION CO. <br />615 E. ALLEN AVE. <br />SAN DIMAS, CA 91773 <br />PHONE: 626-926-7487 <br />CA. LIC. #797455 CLASS A-B-HAZ C10 <br />EXPIRES 07/31/2025 <br />VEEDER ROOT ELECTRICAL <br />SITE ADDRESS: <br />UNITED PACIFIC #5669 <br />1913 WEST EDINGER AVE. <br />SANTA ANA, CA 92704 <br />SCALE: <br />DRAWN BY: <br />DATE: <br />JOB NO. <br />DRAWING NO. <br />CHECKED BY: <br />AS NOTED <br />ETHAN BUI <br />07/19/2023 <br />5669 <br />F7 <br />ALVARO CORONA <br />SHEET <br />F7 <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />L <br />ICENSED CONTRACTOR <br />STATE OF CAL IFORNIA <br />CORONA CONSTRUCTION CO. <br />797455 <br />EXPIRES 07/31/2025 <br />SENSOR ALARM SUMMARY <br />OTHER ALARMS <br />ISD ALARM SUMMARY <br />DISPLAY MESSAGE INDICATOR <br />LIGHT <br />AUDIBLE <br />ALARM <br />ACTIVATION RESULTS CAUSE <br />LIQUID SENSOR STATUS INDICATORS - PIPING SUMP SENSOR (VR-794390-208) & STEEL TANK INTERSTITIAL SENSOR (VR-794390-420) <br />FUEL ALARM RED YES SHUT DOWN OF PROGRAMMED DEVICES, AUDIO, <br />VISUAL & PRINTED COPY OF ALARM <br />AN INTERSTITIAL OR PIPING SUMP LIQUID SENSOR DETECTS LIQUID IN A TANK'S <br />INTERSTITIAL SPACE OR PIPING SUMP. <br />SENSOR OUT ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, <br />VISUAL & PRINTED COPY OF ALARM <br />A SENSOR IS DISCONNECTED OR IS NOT FUNCTIONING PROPERLY <br />SHORT ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, <br />VISUAL & PRINTED COPY OF ALARM <br />AN INTERNAL SHORT HAS OCCURRED IN THE SENSOR <br />SETUP DATA WARNING YELLOW YES AUDIO, VISUAL & PRINTED COPY OF ALARM PROGRAMMING ERROR <br />PRESSURIZED LINE LEAK DETECTOR STATUS INDICATOR - PLLD SENSORS WITH SWIFT CHECK VALVE (VR-848480-003) <br />SHUTDOWN ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, VISUAL & <br />PRINTED COPY OF ALARM <br />SYSTEM SHUT DOWN LINE BECAUSE OF FAILED LINE LEAK TEST, OR AN ALARM ASSIGNED TO <br />DISABLE THE LINE IS ACTIVE <br />GROSS LINE FAIL RED YES SHUTDOWN OF PROGRAMMED DEVICES. <br />AUDIO, VISUAL & PRINTED COPY OF ALARM <br />A.3GPH (11.3 LPH) LINE TEST FAILURE. DISPENSING HALTS WHILE A.LARM IS ACTIVE. <br />FUEL OUT RED YES SHUTDOWN OF PROGRAMMED DEVICES. <br />AUDIO, VISUAL & PRINTED COPY OF ALARM <br />TANK PRODUCT LEVEL BELOW 10-INCH ( 25.4 CM) LEVEL. CANNOT PUMP WHEN ACTIVE, <br />DELIVERY NEEDED <br />SETUP DATA WARNING YELLOW YES AUDIO, VISUAL & PRINTED COPY OF ALARM THE DEFAULT LINE LENGTH WAS NOT CHANGED TO REFLECT THE ACTUAL LINE LENGTH <br />OPEN ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES. <br />AUDIO, VISUAL & PRINTED COPY OF ALARM <br />PRESSURE SENSOR READING IS LESS THAN -8PSI (-51.2 KPA). ONLY TESTED WHILE PUMP IS <br />RUNNING <br />DISPLAYED MESSAGE ISD MONITORING <br />CATEGORY <br />INDICATOR LIGHT OPEN ALARM <br />ISD VAPOR LEAKAGE WARN CONTAINMENT YELLOW VAPOR LEAKAGE DETECTION TEST - WARNING <br />ISD VAPOR LEAKAGE FAIL*CONTAINMENT RED VAPOR LEAKAGE DETECTION TEST - 8TH CONSECUTIVE FAILURE <br />ISD GROSS PRESSURE WARN CONTAINMENT YELLOW GROSS OVER-PRESSURE TEST - WARNING <br />ISD GROSS PRESSURE FAIL*CONTAINMENT RED GROSS OVER-PRESSURE TEST - 8TH CONSECUTIVE FAILURE <br />ISD DEGRAD PRESSURE WARN CONTAINMENT YELLOW DEGRADATION OVER-PRESSURE TEST - WARNING <br />ISD DEGRAD PRESSURE FAIL*CONTAINMENT RED DEGRADATION OVER-PRESSURE TEST - 30TH CONSECUTIVE FAILURE <br />HM: GROSS COLLECT WARNING COLLECTION YELLOW 1-DAY GROSS A/L TEST - WARNING <br />HM: GROSS COLLECT FAIL*COLLECTION RED 1-DAY GROSS A/L TEST - 2ND CONSECUTIVE FAILURE <br />HM: DEGRAD COLLECT WARNING COLLECTION YELLOW 7-DAY DEGRADATION A/L TEST - WARNING <br />HM: DEGRAD COLLECT FAIL*COLLECTION RED 7-DAY DEGRADATION A/L TEST - CONSECUTIVE FAILURE <br />ISD SENSOR OUT PRESSURE WARN SELF-TEST YELLOW ISD SENSOR OUT (SELF-TEST) - WARNING <br />ISD SENSOR OUT PRESSURE FAIL*SELF-TEST RED ISD SENSOR OUT (SELF-TEST) - 8TH CONSECUTIVE FAILURE <br />ISD SETUP WARNING SELF-TEST YELLOW SYSTEM SETUP (SELF-TEST) - WARNING <br />ISD SETUP FAIL*SELF-TEST RED SYSTEM SETUP (SELF-TEST) - 8TH CONSECUTIVE FAILURE <br />DISPLAYED MESSAGE INDICATOR LIGHT SET CONDITIONS CLEAR CONDITIONS <br />MISSING REPLAY <br />SETUP <br />RED ONE OR MORE REQUIRED SHUT DOWN <br />ALARMS HAVE NOT BEEN ASSIGNED TO A <br />RELAY <br />SETUP REQUIRED SHUT DOWN ALARMS <br />MISSING TANK SETUP RED THERE ARE NO VAPOR RECOVERY (GASOLINE) <br />TANKS DEFINED OR A GASOLINE PUMP HAS <br />NOT BEEN ASSIGNED TO A CONTROL (SHUT <br />DOWN) DEVICE IN AT LEAST ONE TANK. <br />COMPLETED GASOLINE TANK SETUP <br />MISSING HOSE SETUP RED THERE ARE NO PRODUCT METERS ASSIGNED <br />TO A HOSE <br />ASSIGN AT LEAST 1 PRODUCT METER TO A <br />HOSE <br />HM: VAPOR FLOW METER SETUP RED INCOMING TRANSACTION FROM A HOSE WITH <br />AN UNAVAILABLE VAPOR FLOW METER <br />CONFIGURE VAPOR FLOW METER (SMART <br />SENSOR) AND ENABLE IT IN ISD <br />MISSING VAPOR PRESSURE SENSOR RED THERE IS NO VAPOR PRESSURE SENSOR SETUP <br />OR DETECTED <br />COMPLETE VAPOR PRESSURE SENSOR SETUP <br />MISSING VAPOR FLOW METER RED THERE IS NO VAPOR FLOW METER SETUP OR <br />DETECTED <br />COMPLETE VAPOR FLOW METER SETUP <br />HM: CHECK VAPOR FLOW METER RED FAILURE OF VOLUME MEASURE TEST. <br />POSSIBLE PROBLEM - VAPOR FLOW METER <br />VOLUME MEASURE TEST PASSES OR VAPOR <br />FLOW METER DECONFIGURED OR TEST <br />CLEARED <br />IMPORTANT: THIS IS A CONTROL DRAWING ONLY AND DOES <br />NOT REFLECT THE ACTUAL LOCATIONS OF <br />CONDUIT ENTRY (SEE NOTE 7 BELOW). <br />WARNING: IN INSTALLATION AND USE OF THIS PRODUCT, <br />COMPLY WITH THE NATIONAL ELECTRICAL CODE; <br />FEDERAL, STATE AND LOCAL CODES. IN ADDITION, <br />TURN OFF POWER AND TAKE OTHER NECESSARY <br />PRECAUTIONS DURING INSTALLATION, SERVICE AND <br />REPAIR TO PREVENT PERSONAL INJURY, PROPERTY <br />LOSS AND EQUIPMENT DAMAGE. <br />WARNING: DISCONNECT ALL POWER BEFORE MAKING ANY <br />CONNECTIONS TO PREVENT DEATH, SERIOUS INJURY, <br />EXPLOSION, OR ELECTRICAL SHOCK. MONITOR MUST <br />NEVER BE OPERATED UNLESS THE FRONT COVER IS <br />CLOSED OVER THE BARRIER TERMINALS IN THE <br />INTRINSICALLY SAFE AREA . <br />1. INTRINSICALLY SAFE WIRING <br />BONDED CONDUIT MEANS THAT THE METALLIC <br />SECTIONS OF CONDUIT ARE PERMANENTLY JOINED TO <br />FORM AN ELECTRICALLY CONDUCTIVE PATH THAT WILL <br />ASSURE ELECTRICAL CONTINUITY, AND THAT THE <br />CONDUIT HAS THE CAPACITY TO CONDUCT SAFELY, <br />ANY CURRENT LIKELY TO BE IMPOSED. <br />A) BONDED & NON-BONDED - THE WIRES BETWEEN <br />THE MONITOR AND EACH PROBE/SENSOR LOCATION <br />MUST BE #14, #16 OR #18 AWG STRANDED COPPER <br />WIRES WITHIN A SHIELDED CABLE. SHIELDED CABLE <br />UST BE RATED AT LESS THAN 100 PICOFARAD PER FOOT <br />AND MUST BE MANUFACTURED WITH A MATERIAL <br />SUITABLE FOR THE ENVIRONMENT, SUCH AS <br />CAROL(TM) C2534 OR BELDEN(TM) 88760 OR 8760. <br />2. CONNECT THE BARRIER GROUND TO THE EARTH GROUND BUS AT THE POWER <br /> DISTRIBUTION PANEL WITH #12 AWG (OR LARGER) CONDUCTOR. <br />3. DENOTES FIELD WIRING CONNECTION USING WATERPROOF CONNECTORS <br /> SUPPLIED WITH THE PROBE(S) AND SENSOR(S). <br />4. INTRINSICALLY SAFE WIRING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE <br /> 504-20 OF THE NEC, ANSI/NFPA 70. <br />5. TO MAINTAIN INTRINSIC SAFETY, PROBE/SENSOR WIRING MUST BE INSTALLED <br /> WITH EITHER SEALED CONDUIT OR DIRECT BURIAL METHODS. <br /> REFER TO "DIRECT BURIAL CABLE INSTALLATION", MANUAL NO. 576013-858. <br />6. ELECTRICAL RATING POWER INPUT 120 VAC, 50/60 HZ, 100 VA MAXIMUM. <br />7. THIS DOCUMENT IS NOT TO BE USED AS A SUBSTITUTE FOR SPECIFIC <br /> EQUIPMENT INSTALLATION MANUALS. FOR INSTALLATION DETAILS USE THE <br /> RESPECTIVE MANUAL: <br />TLS-350(R)576013-879 <br />PLLD 576013-902 <br />WPLLD 576013-923 <br />REPORT <br />PRINTER <br />MULTIPORT CARD <br />OR <br />RS-232 CARD <br />SMART SENSOR <br />MODULE <br />DIM <br />CARD <br />SENSOR <br />MODULE <br />1/0 COMBO <br />MODULE <br />OUTPUT RELAY <br />MODULE <br />EVR/ISD SYSTEM <br />LL CONTROLLER <br />MODULE <br />PLLD <br />CONTROL <br />MODULE <br />NVMEM BOARD - <br />FLAS EEPROM & RAM <br />(REQUIRED) <br />SENSOR <br />MODULE <br />PROBE <br />MODULE <br />SYMBOL LEGEND <br />* ISD SETUP <br /> TLS SETUP <br />* <br />** <br />** <br />CONNECT TO PUMP <br />CONTROL OF THE <br />SELF SERVE SYSTEM. <br />OR DISPENSER, <br />ON THE PRODUCT RELAY <br />OR PUMP CONTRACTOR <br />TO PUMP CONTROLS <br />(SEE NOTE 7.) <br />CIRCUIT BREAKER <br />PANEL <br />WATER WHITE <br />GREEN <br />BLACK <br />GROUND <br />REDFUEL <br />VAPOR <br />WHITE <br />BLACK <br />WATER <br />GROUND <br />RED <br />BLACK <br />WHITE <br />GROUND <br />B <br />A <br />WHITE <br />WHITE <br />WHITE <br />BLACK <br />BLACK <br />BLACK <br />(E)JUNCTION <br />BOX <br />NON - HAZARDOUS AREA HAZARDOUS AREA <br />WEATHERPROOF JUNCTION BOXES <br />1 PER PROBE OR SENSOR <br />(13) SUMP <br />SENSORS <br />(3) TANK <br />LEVEL <br />PROBES <br />(3) TANK <br />ANNULAR <br />(7) PIPING <br />VAC SENSORS <br />(1) ATMOSPHERIC <br />SENSOR <br />(1) ISD <br />PRESSURE <br />SENSOR <br />(13) RESERVOIR <br />SENSORS <br />(3) PLLDs <br />(6) ISD FLOW <br />METERS <br />MODEL #794380-208 <br />(4 AT TANKS- <br />6 AT DISPENSERS) <br />MODEL #847390-111 <br />MODEL #794390-303 <br />MODEL #330020-471 <br />MODEL #33250-001 <br />(1 AT VAPOR POLISHER) <br />MODEL #331946-001 <br />MODEL #794380-304 <br />(4 AT TANKS- <br />6 AT DISPENSERS <br />1 AT VENT TRANSITION SUMP) <br />MODEL #848480-001 <br />MODEL #332374 <br />WPLLD CONNECTION <br />TO L1 & L2 (PUMP <br />POWER) FOR DATA <br />COLLECTION <br />WPPLD <br />TO PUMP CONTROLS <br />(SEE NOTE 7.) <br />AIR FLOW METER <br />VAPOR PRESSURE SENSOR <br />DISPENSER FUEL <br />METER DATA SUMP SENSORS <br />ISD REPORT ACCESS <br />RS-232 <br />OVERFILL <br />ALARM <br />OR <br />STP CONTROL <br />PLLD's MAG PROBES SUMP SENSORS <br />NEW TLS-350 PANEL <br />ATMOSPHERIC SENSOR <br />HEALY TANK <br />2" VENTS TO VENT RISERS AND CANISTERS <br />DISPENSER VAPOR <br />RETURN LINE <br />TANK #1 TANK #2 <br /> MAG <br />PROBE <br /> MAG <br />PROBE <br />STPSTP <br />TO TLS CONSOLE <br />TO TLS CONSOLE <br />TO TLS CONSOLE <br />TO TLS CONSOLE <br />91 U/L87 U/L <br />TO SMART SENOR <br /> MODULE <br />TO SMART SENOR <br /> MODULE <br />TO SMART SENOR <br /> MODULE <br />TO SMART SENOR <br /> MODULE <br />DISPENSER VAPOR <br />RETURN LINE <br /> TO TANKS <br />VAPOR PRESSURE <br />SENSOR <br />(1 PER SITE) <br />AIR FLOW METER <br /> (1 PER DISPENSER) <br />FROM HOSE <br />VAPOR LINE <br />BARRIER GROUND <br />CHASSIS GROUND <br />AC NEUTRAL <br />AC LINE RIGID <br />CONDUIT <br />VEEDER ROOT <br />TLS-350 PANEL <br />INSTALL NEW SOFTWARE <br />VERSION 1.05 <br />1 2 3 41234 <br />PROBE/THERMISTOR INTERFACE MODULE <br />PROBE THERMISTOR <br />1 2 3 4 5 6 <br />1 2 <br />1 2 3 4 5 6 7 <br />1 2 3 4 5 6 7 8 <br />1 2 3 4 5 6 7 8 <br />1 <br />1 1 <br />1 1 <br />2 2 3 3 4 4 5 5 <br />2 2 3 3 4 4 5 5 <br />2 3 4 5 6 <br />CA B CA B CA B CA B CA B CA B <br />GF W GF W GF W GF W GF W <br />GV W GV W GV W GV W GV W <br />1 2 3 4 <br />3 3 4 4 <br />M UPR PO M UPR PO M UPR PO <br />M UPR PO M UPR PO M UPR PO <br />NC NO C NC NO C <br />I/D COMBINATION MODULE <br />PRESSURE LINE LEAK CONTROLLER MODULE <br />WPLLD CONTROLLER MODULE <br />WPLLD AC INTERFACE MODULE <br />PUMP SENSE MODULE SMART SENSOR / PRESS MODULE <br />INTERSTITIAL SENSOR INTERFACE MODULE <br />VAPOR SENSOR INTERFACE MODULE <br />GROUNDWATER SENSOR INTERFACE MODULE <br />TYPE A INTERFACE MODULE <br />TYPE B INTERFACE MODULE <br />PRESSURE LINE LEAK INTERFACE MODULE <br />NC NO C NC NO C <br />INPUT OUTPUT <br />OVERFILL ALARM - MODEL #790091-001 <br />ACKNOWLEDGMENT SWITCH - MODEL #790095-001 <br />(SHIELD DEVICE <br />CABLES) <br />RIGID <br />CONDUIT TERMINATION <br />POINTS FOR <br />SHIELDED CABLE <br />115 VAC <br />HOT <br />115 VAC <br />NEUTRAL <br />N L <br />1 2 3 <br />RIGID <br />CONDUIT <br />RIGID <br />CONDUIT <br />INPUT RELAY <br />PRESSURE <br />XMIT <br />PROBE <br />THERMISTOR <br />SENSOR <br />SENSOR <br />GROUND <br />WATER <br />SENSOR <br />VAPOR <br />SENSOR <br />SENSOR <br />SMART <br />SENSOR <br />PUMP <br />1-2 3-4 5-6 7-8 9-10 <br />SUMP <br />SENSOR <br />323 <br />304 <br />TANK #3 <br /> MAG <br />PROBE <br />STP <br />TO TLS CONSOLE <br />TO TLS CONSOLE <br />DIESEL <br />SUMP <br />SENSOR <br />323 <br />304 <br />SUMP <br />SENSOR <br />323304 <br />SUMP <br />SENSOR <br />323304 <br />SUMP <br />SENSOR <br />208 <br />304 <br />11-12 <br />304 <br />TO SMART SENOR <br /> MODULE <br />TO SMART SENOR <br /> MODULE <br />SUMP <br />SENSOR <br />208 <br />SIGNED 5/14/24 <br />1913 W Edinger Ave - <br />101118671 & 201824107/2/2024