6"MIN. CLR.THERMOSTAT
<br />1'-6"ELECT. WALL OUTLET
<br />44" A.F.F. TO TOP OF BOXDOOR HANDLE
<br />6" +80" TO 96" A.F.F. WALL MOUNTED F.L.S.
<br />STROBE DEVICE
<br />NOTES:
<br />1. ALL VERTICAL DIMENSIONS ARE
<br />SHOWN FROM THE FINISH FLOOR TO
<br />LOCATION SHOWN.
<br />2. THE THERMOSTAT AND CARD
<br />READERS SHALL BE LOCATED
<br />SO THAT THE TOP OF THE OUTLET
<br />BOX IS NO MORE THAT 48" NOR
<br />LESS THAN 15" TO THE BOTTOM
<br />OF THE OUTLET BOX ABOVE THE
<br />FINISHED FLOOR (2022 CBC 11B-308.2.1)
<br />3. DIMENSIONS SHOWN ARE FOR
<br />REFERENCE USE ONLY. FINAL LOCATION OF
<br />OUTLETS AND EQUIPMENT TO BE
<br />APPROVED BY SAA AND/OR TENANT.
<br />MILLWORK MOUNTING HEIGHTS
<br />CERTAIN ELEVATION DIMENSIONS ARE
<br />ASSOCIATED WITH CODE REQUIRED
<br />MAXIMUM OR MINIMUM MOUNTING
<br />HEIGHTS. SUCH DIMENSIONS SHOULD BE
<br />HELD DESPITE VARIATIONS IN THE
<br />SLAB. CODE DIMENSIONS ARE IN
<br />PARENTHESIS WITH AN ASTERISK NEXT TO
<br />THE CRITICAL DIMENSION. E.G.: (*+15"
<br />MIN.)
<br />CONTROL ELEVATIONS ARE COMPRISED OF:
<br />FINISH CEILING LEVEL (FCL)
<br />FINISH FLOOR LEVEL (FFL)
<br />TOP OF SLAB (TOS)
<br />ALL DIMENSIONS GIVEN ARE FROM FFL
<br />DATUM. FINISH FLOOR MATERIAL IS
<br />ASSUMED TO BE 3/8" THICK GLUE
<br />DOWN CARPET. FLOOR FINISH AND
<br />THICKNESS WILL VARY FROM
<br />LOCATION TO LOCATION. REFER TO
<br />PLANS AND DETAILS FOR SPECIFIC
<br />FLOORING INFORMATION.
<br />NO ALLOWANCE HAS BEEN MADE FOR
<br />ANY DEPRESSIONS OR ELEVATIONS IN
<br />THE SLAB. ELEVATION HEIGHTS
<br />SHOULD TAKE INTO ACCOUNT ANY
<br />VARIATIONS IN THE FLOOR SLAB.
<br />ELECTRICAL MOUNTING HEIGHTS
<br />CONTROL ELEVATIONS
<br />KEY CARD READER
<br />CLG. HT.
<br />+60"
<br />BOT. OF CASEWORK OVHDS.
<br />(* +2'-10" MAX.)
<br />COUNTER +2'-10"
<br />+2'-6"
<br />MILLWORK DESK
<br />TYP. J-BOX OUTLET +18"*
<br />COAT CLOSET SHELF +48"
<br />+34"-44"
<br />DOOR HANDLE
<br />FIN. FLR.
<br />6"
<br />FIRE EXTINGUISHER CABINET, SEE A2.0
<br />FOR TYPE. PAINT CABINET TO
<br />MATCH ADJACENT WALL. PROVIDE
<br />NEW FIRE EXTINGUISHER SUSPENDED IN
<br />CABINET
<br />TOP OF BOX
<br />CL
<br />CL
<br />CL
<br />WALL SWITCH, DIMMER OR WALL
<br />MOUNTED MOTION SENSOR, WALL
<br />PHONES AND "J" BOXES AT
<br />COUNTERS.
<br />0'-0"
<br />J BOX AT DESK +21"
<br />3
<br />CLOSE
<br />STOP
<br />OPEN
<br />B
<br />4
<br />2*1
<br />ALARM
<br />S
<br />3 LC
<br />LC
<br />L C
<br />LC
<br />LC
<br />RAIL4'-0"EMERG. TEL.CONTROL PANEL
<br />SEE BELOW 6'-0" TO 6'-6"PHOTOELECTRIC TUBEBYPASS SWITCH32"1 1/2"MIN.5'-0"6'-0" MIN.3'-6"4'-3" MIN.4'-6" MIN. 42"
<br />MIN.
<br />6'-8" MIN.4'-0" MAX.3/8" MIN. SEPARATION3/4"2'-11" MIN. A.F.F. ELEVATOR SIGNAGE
<br />IDENTIFICATION FOR THE VISUALLY IMPAIRED SHALL BE AS FOLLOWS PASSENGER ELEVATOR CONTROLS SHALL HAVE A
<br />MINIMUM DIMENSION OF 3/4 INCHES AND SHALL BE RAISED 1/8 INCH PLUS OR MINUS 1/32 ABOVE THE SURROUNDING
<br />SURFACE. CONTROL BUTTONS SHALL HAVE SQUARE SHOULDERS, AND SHALL BE ACTIVATED BY MECHANICAL MOTION
<br />WHICH IS DETECTABLE. ALL CONTROL BUTTONS SHALL BE DESIGNATED BY A 5/8 INCH MINIMUM., ARABIC NUMERAL,
<br />STANDARD ALPHABET CHARACTER, OR STANDARD SYMBOL IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON. A
<br />BRAILLE SYMBOL SHALL BE LOCATED IMMEDIATELY BELOW THE NUMERAL, CHARACTER, OR STANDARD SYMBOL. A
<br />MINIMUM CLEARANCE OF 3/8 INCH OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF
<br />CONTROL BUTTONS. NOTE. SEE FIGURE BELOW. THEN RAISED CHARACTERS SHALL BE WHITE ON BLACK BACKGROUND.
<br />CONTROLS AND EMERGENCY EQUIPMENT IDENTIFIED BY RAISED SYMBOLS SHALL INCLUDE, BUT NOT BE LIMITED TO DOOR
<br />OPEN, DOOR CLOSED, ALARM BELL EMERGENCY STOP, AND TELEPHONES. PASSENGER ELEVATOR LANDING JAMBS ON ALL
<br />ELEVATOR FLOORS, SHALL HAVE THE NUMBER OF THE FLOOR ON WHICH THE JAMB IS LOCATED DESIGNATED BY RAISED
<br />ARABIC NUMERALS WHICH ARE A MINIMUM OF 2 INCHES IN HEIGHT AND RAISED BRAILLE SYMBOLS TO BE LOCATED
<br />APPROXIMATELY 5 FEET ABOVE THE FLOOR ON THE JAMB PANELS ON BOTH SIDES OF THE DOOR SO THAT THEY ARE
<br />VISIBLE FROM WITHIN THE ELEVATOR. RAISED BRAILLE SYMBOLS SHALL BE PLACED DIRECTLY TO THE LEFT OF THE
<br />CORRESPONDING RAISED ARABIC NUMERALS. THE RAISED CHARACTERS SHALL BE ON A CONTRASTING BACKGROUND.
<br />GENERAL NOTE:
<br />PASSENGER ELEVATORS SHALL BE ACCESSIBLE.
<br />ELEVATORS REQUIRED TO BE ACCESSIBLE
<br />SHALL BE DESIGNATED AND CONSTRUCTED
<br />TO COMPLY WITH CBC 2022 SECTION 11B-407
<br />AND WITH ASME A17.1, SAFETY CODE FOR
<br />ELEVATORS AND ESCALATORS.
<br />HALL LANTERN
<br />FLOOR LANDING ON BOTH SIDES
<br />CALL BUTTON
<br />42"
<br />MIN.
<br />GRAB BAR
<br />CENTER OPENING DOOR
<br />ELEVATOR CONTROL PANEL
<br />ELEVATOR EXTERIOR ELEVATION
<br />ELEVATOR INTERIOR ELEVATION
<br />5'-8" MIN.
<br />3'-0"
<br />MIN.4'-3" MIN.4'-6" MIN.GRAB BAR
<br />SIDE OPENING DOOR
<br />5/8" MIN. CHARACTERS
<br />AND SYMBOLS HEIGHT
<br />PLACE STAR ALONGSIDE
<br />MAIN EXIST FLOOR
<br />NUMBER
<br />AA
<br />1
<br />COLUMN GRID
<br />LINES
<br />0'-0"
<br />LEVEL 1 VERTICAL ELEVATION
<br />FIRST FLOOR
<br />EL. 0'-0"
<br />DATUM POINT
<br />SPOT ELEVATION
<br />A-100
<br />1
<br />SHEET NUMBER
<br />PLAN OR DETAIL
<br />DESIGNATION
<br />A-100
<br />1
<br />SHEET NUMBER
<br />VIEW DIRECTION
<br />WALL/DETAIL
<br />SECTION
<br />DESIGNATION
<br />A-502
<br />1
<br />2
<br />3
<br />4
<br />SHEET NUMBER
<br />INTERIOR
<br />ELEVATION
<br />DESIGNATION
<br />A-100
<br />1
<br />SHEET NUMBER
<br />VIEW DIRECTION
<br />WALL/DETAIL
<br />SECTION
<br />DESIGNATION
<br />NORTH ARROW
<br />3
<br />REVISION NUMBER
<br />AREA OF REVISION
<br />AREA NOT IN CONTRACT
<br />(NIC)
<br />BREAK LINE
<br />MATCH LINE
<br />SEE XX/X-XXX
<br />SHEET NUMBER ON
<br />WHICH CONTINUATION
<br />IS FOUND
<br />45925C EQUIPMENT AND
<br />FURNITURE TAG
<br />ALIGN SURFACES
<br />SITE LOCATION
<br />SHEET NUMBER SHEET NAME
<br />ARCHITECTURE
<br />A-0.1 ABBREVIATION, NOTES, SYMBOLS, INDEX, MAP, BUILDING DATA, ETC.
<br />A-0.2 GENERAL NOTES
<br />A-0.3 GENERAL NOTES AND SPECIFICATIONS
<br />A-0.5A SITE PLAN AND ACCESSIBILITY PATH OF TRAVEL
<br />A-0.5B SITE PLAN AND ACCESSIBILITY PATH OF TRAVEL
<br />A-0.5C EXIT ROUTES AND TACTILE SIGNAGE
<br />A-0.5D EXISTING & PROPOSED 6TH FLOOR PLAN
<br />A-0.6A BASE BUILDING ACCESSIBILITY
<br />A-0.6B BASE BUILDING ACCESSIBILITY
<br />A-0.7 BASE BUILDING RESTROOM ACCESSIBILITY PLANS
<br />A-1.0 DEMOLITION PLAN
<br />A-1.1 CEILING DEMOLITION PLAN
<br />A-2.0 CONSTRUCTION PLAN
<br />A-3.0 POWER / VOICE / DATA PLAN
<br />A-4.0 REFLECTED CEILING PLAN
<br />A-5.0 FINISH PLAN
<br />A-20.0 INTERIOR ELEVATIONS
<br />A-30.0 WALL PARTITION AND HEAD DETAILS
<br />A-30.2 CEILING DETAILS
<br />A-30.4 GLASS PARTITION DETAILS
<br />A-30.5 MILLWORK DETAILS WITH TAB PULLS
<br />ELECTRICAL
<br />E-1 ELECTRICAL COVER SHEET
<br />E-2 GENERAL ELECTRICAL SPECIFICATIONS PART 1 OF 2
<br />E-3 GENERAL ELECTRICAL SPECIFICATIONS PART 2 OF 2
<br />E-4.1 TITLE 24 ENERGY CALCULATIONS
<br />E-4.2 TITLE 24 ENERGY ELC FORMS
<br />E-5.1 ELECTRICAL LIGHTING PLAN
<br />E-5.2 EMERGENCY FOOTCANDLE CALCULATIONS
<br />E-6 ELECTRICAL POWER PLAN
<br />E-7 PANEL SCHEDULES
<br />E-8 TYPICAL LIGHTING CONTROLS DIAGRAMS (WATTSTOPPER)
<br />E-9 ELECTRICAL DETAILS
<br />MECHANICAL
<br />M-1 HVAC NOTES & DETAILS
<br />M-2 HVAC PLAN
<br />M-3 HVAC TITLE 24
<br />PLUMBING
<br />P-1.1 PLUMBING COVER SHEET
<br />P-1.2 PLUMBING TITLE 24 & DETAILS
<br />P-2 PLUMBING PLAN
<br />P-3 PLUMBING SPECIFICATION
<br />STRUCTURAL
<br />S1.1 GENERAL NOTES
<br />S1.2 TYPICAL DETAILS
<br />S1.2 .1 TYPICAL DETAILS
<br />S2.2 7TH FLOOR FRAMING
<br />S2.2A 7TH FLOOR FRAMING PLAN (UNISTRUT OPTION ALTERNATIVE)
<br />1. BUILDING PERMIT INFORMATION
<br />BUILDING 6 E HUTTON CENTRE DRIVE
<br />ADDRESS:SANTA ANA, CA 92707
<br />BUILDING OWNER:KB BPG GRIFFEN TOWERS, LLC
<br />5 & 6 HUTTON CENTRE DRIVE
<br />SANTA ANA, CA 92707
<br />CONTACT: WILL DICKINSON
<br />EMAIL: WDICKINSON@BARKERPACIFIC.COM
<br />CONSTRUCTION TYPE:I-A
<br />OCCUPANCY:B-OFFICE
<br />SPRINKLER BUILDING:FULLY SPRINKLERED
<br />NUMBER OF FLOORS:13
<br />TOTAL FLOOR AREA:21,932 SQ. FT.
<br />AREA OF WORK:±8,070 SQ. FT.
<br />SCOPE OF WORK: TENANT IMPROVEMENT WORK ON ±8,070 SQ. FT. OF THE TOTAL 6TH FLOOR AREA.
<br />EXPANSION OF EXISTING SUITE 650 CHANGE FROM ±4,556 SQ. FT. TO ±8,070 SQ. FT.
<br />WITH NEW DEMISING WALL. EXISTING SUITE 625 CHANGED FROM ±6,865 SQ. FT. TO
<br />±3,597 SQ. FT. WITH NEW DEMISING WALL. NEW WALL, POWER, LIGHTING AND FINISHES.
<br />2. C.E.C. TITLE 24/DISABLE ACCESS COMPLIANCE
<br />THE PROJECT SHALL COMPLY WITH CCR TITLE 24 (PART 6 - CALIFORNIA ENERGY CODE) FOR ENERGY COMPLIANCE
<br />AND THE AMERICANS WITH DISABILITIES ACT (ADA) FOR DISABLED ACCESS REQUIREMENTS.
<br />3. EXISTING LIFE-SAFETY SYSTEMS TO BE MODIFIED
<br />EXISTING FIRE/LIFE SAFETY SYSTEM IS TO BE MODIFIED TO COMPLY TO CURRENT FIRE/LIFE SAFETY STANDARDS.
<br />REFER TO ELECTRICAL ENGINEER DRAWING FOR SCOPE OF WORK.
<br />4. CODE COMPLIANCE
<br />THE PROJECT SHALL COMPLY WITH CODES, ORDINANCES, OR LAWS HAVING JURISDICTION ON THE PROJECT.
<br />WHICH INCLUDE, BUT ARE NOT LIMITED TO:
<br />2022 CALIFORNIA BUILDING CODE - ( PART 2, TITLE 24, CCR )
<br />2022 CALIFORNIA ELECTRICAL CODE- ( PART 3, TITLE 24, CCR )
<br />2022 CALIFORNIA MECHANICAL CODE- ( PART 4, TITLE 24, CCR )
<br />2022 CALIFORNIA PLUMBING CODE- ( PART 5, TITLE 24, CCR )
<br />2022 CALIFORNIA FIRE CODE- (PART 9, TITLE 24, CCR )
<br />2022 CALIFORNIA BUILDING STANDARDS CODE ( PART 12, TITLE 24, CCR )
<br />AMERICANS WITH DISABILITIES ACT (ADA)
<br />2022 CALIFORNIA ENERGY CODE
<br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN)
<br />SANTA ANA MUNICIPAL CODE
<br />5. SEPARATE PERMITS
<br />PROVIDE SEPARATE PERMITS FOR THE ELECTRICAL, MECHANICAL, PLUMBING, SIGNS,
<br />FIRE SPRINKLER AND FIRE PROTECTION.
<br />ELEVATOR MOUNTING HEIGHTS
<br />AREA OF WORK
<br />ELEVATOR MOUNTING HEIGHTS
<br />ARCHITECT:
<br />SAA INTERIORS + ARCHITECTURE
<br />18600 MACARTHUR BLVD. SUITE 100
<br />IRVINE, CA 92612
<br />PHONE: 949-724-8959
<br />DIRECT: 949-608-3748
<br />CONTACT: MICHAEL PARR
<br />EMAIL: MPARR@SAAIA.COM
<br />STRUCTURAL ENGINEER:
<br />MELQART, INC.
<br />714 W OLYMPIC BLVD., SUITE 617
<br />LOS ANGELES, CA 90015
<br />PHONE: 213-590-6119
<br />CELL: 909-374-4339
<br />CONTACT: RICHARD DAOUD
<br />EMAIL: RICHARD.DAOUD@MELQARTINC.COM
<br />MECHANICAL ENGINEER:
<br />ENGINEERED SPACES, INC.
<br />333 CITY BLVD. WEST, SUITE 300
<br />ORANGE, CA 92868
<br />PHONE: 714- 449-1646
<br />CELL: 949-290-8487
<br />CONTACT: SORIN A. BRIE
<br />EMAIL: SORINBRIE@ESI-ENG.COM
<br />PLUMBING ENGINEER:
<br />ENGINEERED SPACES, INC.
<br />333 CITY BLVD. WEST, SUITE 300
<br />ORANGE, CA 92868
<br />PHONE: 714- 449-1646
<br />CELL: 949-290-8487
<br />CONTACT: SORIN A. BRIE
<br />EMAIL: SORINBRIE@ESI-ENG.COM
<br />ELECTRICAL ENGINEER:
<br />ENGINEERED SPACES, INC.
<br />333 CITY BLVD. WEST, SUITE 300
<br />ORANGE, CA 92868
<br />PHONE: 714- 449-1646
<br />CELL: 949-290-8487
<br />CONTACT: SORIN A. BRIE
<br />EMAIL: SORINBRIE@ESI-ENG.COM
<br />CONTACT DIRECTORY PROJECT INFORMATION DRAWING INDEXFIRE PREVENTIONGENERAL DIRECTORY
<br />TYPICAL MOUNTING VICINITY MAPDRAFTING CONVENTION
<br />KEYPLANDRAFTING CONVENTION NOTES
<br />CLIENT:
<br />KB BPG GRIFFEN TOWERS, LLC
<br />5 & 6 HUTTON CENTRE DRIVE
<br />SANTA ANA, CA 92707
<br />CONTACT: WILL DICKINSON
<br />EMAIL: WDICKINSON@BARKERPACIFIC.COM
<br />6 E HUTTON CENTRE DR.
<br />SUITE 650
<br />SANTA ANA, CA 92707
<br />1. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS TAKE PRECEDENCE OVER
<br />ALL. NOTIFY ARCHITECT OF CONFLICTS OR DISCREPANCIES IN WRITING.
<br />2. DIMENSION CONVENTIONS:
<br />a) HORIZONTAL DIMENSIONS ARE SHOWN FROM FACE OF FINISH, UNLESS OTHERWISE NOTED.
<br />b) DIMENSIONS NOTED "CLEAR" OR "CLR." MUST BE PRECISELY MAINTAINED: ALLOWING FOR THICKNESS OR
<br />MATERIALS.
<br />c) DIMENSIONS ARE NOT ADJUSTABLE WITHOUT ARCHITECT'S APPROVAL, UNLESS NOTED.
<br />d) DIMENSIONS TO EXTERIOR WINDOW WALL ARE TO INSIDE FINISHED FACE OF THE WALL, UNLESS OTHERWISE
<br />NOTED.
<br />e) DIMENSIONS TO EXTERIOR GLAZING ARE TO THE INSIDE FACE OF THE EXTERIOR GLAZING.
<br />f) VERTICAL DIMENSIONS ARE FROM THE TOP OF THE FINISHED FLOOR, UNLESS OTHERWISE NOTED.
<br />g) DO NOTE SCALE DRAWINGS. IF ANY ITEM OF WORK CANNOT BE LOCATED, DO NOT PROCEED WITH THE WORK
<br />BEFORE CLARIFYING WITH ARCHITECT.
<br />h) VERIFY DIMENSIONS MARKED "V.I.F." PRIOR TO START OF CONSTRUCTION. REPORT INCONSISTENCIES TO
<br />ARCHITECT.
<br />3. DEFINITION OF TERMINOLOGY:
<br />i) "TYPICAL" MEANS IDENTICAL FOR ALL CONDITIONS, UNLESS OTHERWISE NOTED.
<br />j) "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. VERIFY DIMENSIONS AND
<br />ORIENTATION ON PLANS AND ELEVATIONS.
<br />k) "PROVIDE" MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE.
<br />l) "FURNISH" MEANS FURNISH ONLY, INSTALLATION BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.
<br />m) "INSTALL" MEANS PUT INTO PLACE, SUPPLIED BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.
<br />n) "ALIGN" MEANS ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE.
<br />LTG LIGHTING
<br />LTWT LIGHT WEIGHT
<br />LIN LINEAR
<br />LONG LONGITUDINAL
<br />LP LOW POINT
<br />LVR LOUVER
<br />MAX MAXIMUM
<br />MDF MEDIUM DENSITY FIBERBOARD
<br />MECH MECHANICAL
<br />MED MEDIUM
<br />MEMB MEMBRANE
<br />MET METAL
<br />MEZZ MEZZANINE
<br />MFR MANUFACTURER
<br />MIC MICROWAVE
<br />MIN MINIMUM
<br />MIR MIRROR
<br />MISC MISCELLANEOUS
<br />MUL MULLION
<br />MAINT MAINTENANCE
<br />MSTC MASTIC
<br />MATL MATERIAL
<br />MT METAL THRESHOLD
<br />MLDG MOLDING
<br />MTD MOUNTED
<br />N NORTH
<br />N NEW
<br />NAT NATURAL
<br />NIC NOT IN CONTRACT
<br />NO NUMBER
<br />NUM NOMINAL
<br />NRC NOISE REDUCTION COEFFICIENT
<br />NTS NOT TO SCALE
<br />OC ON CENTER
<br />OD OUTSIDE DIAMETER DIMENSION
<br />OFCI OWNER FURNISHED
<br />CONTRACTOR INSTALLED
<br />OH OPPOSITE HAND
<br />OPNG OPENING
<br />OVHD OVERHEAD
<br />OFF OFFICE
<br />OFOI OWNER FURNISHED
<br />OWNER INSTALLED
<br />P PAINT
<br />PAR PARALLEL
<br />PBD PARTICLE BOARD
<br />PC PERSONAL COMPUTER
<br />PC PIECE
<br />PERP PERPENDICULAR
<br />PL PLATE
<br />PLAM PLASTIC LAMINATE
<br />PLYWD PLYWOOD
<br />PNL PANEL
<br />POL POLISH
<br />PR PAIR
<br />PTN PARTITION
<br />PTD PAPER TOWEL DISPENSER
<br />PTDR PAPER TOWEL DISPENSER
<br />RECEPTACLE
<br />PTR PAPER TOWEL RECEPTACLE
<br />PLBG PLUMBING
<br />PT POINT
<br />LBS POUNDS
<br />PSF POUND SQUARE FOOT
<br />PSI POUND SQUARE INCH
<br />PRCST PRECAST
<br />PREFAB PREFABRICATED
<br />PROJ PROJECTION
<br />QTY QUANTITY
<br />QUAL QUALITY
<br />QT QUARRY TILE
<br />QTRS QUARTERS
<br />R RELOCATED
<br />RA RETURN AIR
<br />RAD RADIUS
<br />RB RESILIENT BASE
<br />REBAR REINFORCING BAR
<br />REF REFERENCE
<br />REFL REFLECTED
<br />REFR REFRIGERATOR
<br />REINF REINFORCED
<br />REQ REQUIRED
<br />RESIL RESILIENT
<br />REV REVISION/ REVISED
<br />RH RIGHT HAND
<br />RM ROOM
<br />RO ROUGH OPENING
<br />RT RESILIENT TILE
<br />RB RUBBER BASE
<br />S SOUTH
<br />SA SUPPLY AIR
<br />SC SOLID CORE
<br />SCH SCHEDULE
<br />SFEC SEMI-RECESSED FIRE
<br />EXTINGUISHER CABINET
<br />SHT SHEET
<br />SIM SIMILAR
<br />SK SINK
<br />SMD SEE MECHANICAL
<br />SND SANITARY NAPKIN DISPENSER
<br />SNR SANITARY NAPKIN RECEPTACLE
<br />SPD SEE PLUMBING DRAWINGS
<br />SPEC SPECIFICATION (S)
<br />SPKR SPEAKER
<br />SQ SQUARE
<br />SSD SEE STRUCTURAL DRAWINGS
<br />STD STANDARD
<br />STL STEEL
<br />STOR STORAGE
<br />STRL STRUCTURAL
<br />SUR SURFACE
<br />SUSP SUSPENDED
<br />SYM SYMMETRICAL
<br />SYS SYSTEM
<br />SCD SEAT COVER DISPENSER
<br />SECT SECTION
<br />SSK SERVICE SINK
<br />SD SOAP DISPENSER
<br />STA STATION
<br />T TREAD
<br />TAN TANGENT
<br />TBD TO BE DETERMINED
<br />TEL TELEPHONE
<br />TEMP TEMPERED
<br />THRES THRESHOLD
<br />TO TOP OF
<br />TPD TOILET PAPER DISPENSER
<br />TV TELEVISION
<br />TYP TYPICAL
<br />TEMP TEMPERATURE
<br />TER TERRAZZO
<br />TOC TOP OF CONCRETE
<br />TC TOP OF CURB
<br />TOS TOP OF STEEL
<br />TS TUBULAR STEEL
<br />TW TOP OF WALL
<br />TB TOWEL BAR
<br />UNF UNFINISHED
<br />UON UNLESS OTHERWISE NOTED
<br />UR URINAL
<br />UTIL UTILITY
<br />UL UNDERWRITERS LABORATORY
<br />VAR VARIABLE
<br />VIF VERIFY IN FIELD
<br />VIN VINYL
<br />VERT VERTICAL
<br />VEST VESTIBULE
<br />VCT VINYL COMPOSITION TILE
<br />VWC VINYL WALL COVERING
<br />WC WALL COVERING
<br />WC WATER CLOSET
<br />WD WOOD
<br />WIN WINDOW
<br />WO WHERE OCCURS
<br />WP WATERPROOF
<br />WPT WORK POINT
<br />WR WATER RESISTANT
<br />WS WEATHERSTRIPPING
<br />WT WEIGHT
<br />WDT WIDTH
<br />&AND
<br /><ANGLE
<br />@ AT
<br />℄CENTERLINE
<br />[CHANNEL
<br />DIAMETER OR ROUND
<br />'FOOT (FEET)
<br />"INCH (INCHES)
<br />PERPENDICULAR
<br /># POUND OR NUMBER
<br />SQUARE FOOT (FEET)
<br />ABV ABOVE
<br />A/C AIR CONDITIONING
<br />ACC ACCESS
<br />ACT ACOUSTIC TILE
<br />ADJ ADJUSTABLE
<br />AFF ABOVE FINISHED FLOOR
<br />AL ACTIVE LEAF
<br />ALUM ALUMINUM
<br />ALT ALTERNATE
<br />AP ACCESS PANEL
<br />APPV APPROVED
<br />ARCH ARCHITECTURAL
<br />AUTO AUTOMATIC
<br />AVG AVERAGE
<br />BD BOARD
<br />BATT INSUL BATTING INSULATION
<br />BKG BACKING
<br />BLDG BUILDING
<br />BLKG BLOCKING
<br />BM BEAM
<br />BOW BACK OF WALL
<br />BOT BOTTOM
<br />BRKT BRACKET
<br />CAB CABINET
<br />CLG CEILING
<br />CLKG CAULKING
<br />CLO CLOSET
<br />CLR CLEAR
<br />COL COLUMN
<br />CONC CONCRETE
<br />CONF CONFERENCE
<br />CONN CONNECTION
<br />CONSTR CONSTRUCTION
<br />CONT CONTINUOUS
<br />CORR CORRIDOR
<br />CPT CARPET
<br />CSMT CASEMENT
<br />CT CERAMIC TILE
<br />CTR CENTER
<br />CWK CASEWORK
<br />CFCI CONTRACTOR FURNISHED
<br />CONTRACTOR INSTALLED
<br />CJ CONTROL JOINT
<br />CNTR COUNTER
<br />DBL DOUBLE
<br />DEMO DEMOLISH (DEMOLITION)
<br />DEPT DEPARTMENT
<br />DET DETAIL
<br />DF DRINKING FOUNTAIN
<br />DIA DIAMETER
<br />DIM DIMENSION
<br />DISP DISPENSER
<br />DIV DIVISION
<br />DN DOWN
<br />DO DOOR OPENING
<br />DR DOOR
<br />DW DISH-WASHER
<br />DWG DRAWING
<br />DWR DRAWER
<br />DIAG DIAGONAL
<br />E EAST
<br />(E) EXISTING
<br />EA EACH
<br />EL ELEVATION
<br />ELEC ELECTRICAL
<br />ELEV ELEVATOR
<br />EMER EMERGENCY
<br />ENCL ENCLOSURE
<br />ENG ENGINEER
<br />ENT ENTRANCE
<br />EQ EQUAL
<br />EQPT EQUIPMENT
<br />EWC ELECTRIC WATER COOLER
<br />EXH EXHAUST
<br />EXP EXPANSION
<br />EXT EXTERIOR
<br />FA FIRE ALARM
<br />FDC FIRE DEPARTMENT CONNECTION
<br />FDN FOUNDATION
<br />FE FIRE EXTINGUISHER
<br />FEC FIRE EXTINGUISHER CABINET
<br />FF FINISH FACE
<br />FHC FIRE HOSE CABINET
<br />FIN FINISH
<br />FIX FIXTURE
<br />FLR FLOOR
<br />FLUOR FLUORESCENT
<br />FRPF FIREPROOF
<br />FR FIRE RESISTANT
<br />FRMG FRAMING
<br />FS FULL SIZE
<br />FT FOOT OR FEET
<br />FOC FACE OF CONCRETE
<br />FOS FACE OF STUDS
<br />FOW FACE OF WALL
<br />FES FIRE EXTINGUISHER SURFACE MOUNTED
<br />FD FLOOR DRAIN
<br />FURR FURRING
<br />GB GRAB BAR
<br />GD GARBAGE DISPOSAL
<br />GEN GENERAL
<br />GL GLASS
<br />GYP GYPSUM
<br />GA GAGE OR GAUGE
<br />GALV GALVANIZED
<br />G GAS
<br />GYP BD GYPSUM WALLBOARD
<br />GC GENERAL CONTRACTOR
<br />HDCP HANDICAPPED
<br />HDF HIGH DENSITY FIBERBOARD
<br />HDWD HARDWOOD
<br />HDEW HARDWARE
<br />HM HOLLOW METAL
<br />HO HOLD OPEN
<br />HOR HORIZONTAL
<br />HR HOUR
<br />HT HEIGHT
<br />HVAC HEATING VENTING AIR
<br />CONDITIONING
<br />HW HOT WATER
<br />HWH HOT WATER HEATER
<br />HDR HANDRAIL
<br />HBD HARDBOARD
<br />HTR HEATER
<br />HT HEIGHT
<br />HC HOLLOW CORE
<br />HM HOLLOW METAL INSULATED
<br />INCL INCLUDING
<br />INFO INFORMATION
<br />INSUL INSULATION
<br />INT INTERIOR
<br />INTER INTERMEDIATE
<br />IN INCH
<br />ID INSIDE DIAMETER
<br />IDENT IDENTIFICATION
<br />JAN JANITOR
<br />JB JUNCTION BOX
<br />JT JOINT
<br />JST JOIST
<br />K KEY
<br />KL KEY LOCK
<br />KP KICK PLATE
<br />KIT KITCHEN
<br />LAM LAMINATE
<br />LAV LAVATORY
<br />LH LEFT HANDED
<br />LAB LABORATORY
<br />LT LIGHT
<br />1. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA OR WHEN
<br />SERVING AN OCCUPANT LOAD OF 50 OR MORE.
<br />2. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR
<br />EFFORT. (2022 CBC 1010.2).
<br />3. EXCEPTION: THIS REQUIREMENT SHALL NOT APPLY TO EXTERIOR EXIT DOORS IN A GROUP "B" OCCUPANCY IF
<br />THERE IS A VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED
<br />WHEN SPACE IS OCCUPIED". THE LETTERS SHALL BE NOT LESS THAN 1 INCH HIGH ON A CONTRASTING
<br />BACKGROUND. THE LOCKING DEVICE MUST BE A TYPE THAT WILL BE READILY DISTINGUISHABLE AS LOCKED.
<br />4. PANIC HARDWARE, WHEN INSTALLED, SHALL COMPLY WITH ALL APPLICABLE BUILDING CODE REQUIREMENTS. THE
<br />ACTIVATING MEMBER SHALL BE MOUNTED AT A HEIGHT OF NOT LESS THAN 34 INCHES NOR MORE THAN 44
<br />INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE
<br />DIRECTION OF EXIT TRAVEL.
<br />5. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING
<br />SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE
<br />LESS THAN 1 FOOT-CANDLE (11-LUX) AT THE WALKING SURFACE LEVEL. (2022 CBC 1013.5 AND 1013.6)
<br />6. EXIT ILLUMINATION SHALL COMPLY WITH 2022 CBC SECTION 1008 AND 1013.
<br />7. EXIT SIGNS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE OTHERWISE NECESSARY TO CLEARLY
<br />INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF 50 OR MORE.
<br />8. EXCEPTION: MAIN EXTERIOR EXIT DOORS WHICH OBVIOUSLY AND CLEARLY ARE IDENTIFIABLE AS EXITS NEED NOT
<br />BE SIGNED WHEN APPROVED BY THE BUILDING OFFICIAL.
<br />9. WHEN NECESSARY, THE FINAL LOCATION AND QUANTITY OF EXIT SIGNS SHALL BE DETERMINED BY THE FIRE
<br />DEPARTMENT PRIOR TO CONSTRUCTION OF ANY WORK.
<br />10. THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYMBOLS ON EXIT SIGN SHALL BE IN HIGH CONTRAST
<br />WITH THEIR BACKGROUND (3/4" x 6" LETTERS MIN.)
<br />11. ALL RATED CORRIDOR DOORS SHALL HAVE A THRESHOLD WITH A SMOKE AND DRAFT SEAL AT HEAD AND JAMBS.
<br />12. INTERIOR WALL AND CEILING FINISHES SHALL BE NON-COMBUSTIBLE OR HAVE A FLAME SPREAD INDEX OF 0 TO 25;
<br />SMOKE-DEVELOPED INDEX 0-450.
<br />13. ALL DRAPES, HANGING CURTAINS AND OTHER DECORATIVE MATERIALS SHALL BE TREATED AND MAINTAINED IN A
<br />FLAME RETARDANT CONDITION.
<br />14. FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED WALLS OR CEILING AS
<br />PER 2022 CBC SECTION 716. SMOKE DAMPERS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED
<br />WALLS OR CEILING AS PER 2022 CBC SECTION 716.
<br />15. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM,
<br />EXTEND/MODIFY FIRE/LIFE SAFETY SYSTEM AS REQUIRED.
<br />16. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM, FIRE
<br />SPRINKLER/OR LIFE SAFETY PLANS MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL PRIOR TO
<br />BUILDING PERMIT ISSUANCE.
<br />17. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM, FIRE SPRINKLER
<br />SYSTEM PLAN MUST BE REVISED AND APPROVED BY THE CITIES FIRE DEPARTMENT PRIOR TO THE INSTALLATION OR
<br />MODIFICATION OF SPRINKLER SYSTEMS.
<br />18. A PORTABLE FIRE EXTINGUISHER WITH A MINIMUM 2A10BC RATING SHALL BE PROVIDED EVERY 75' OF TRAVEL
<br />DISTANCE FROM ANY POINT WITHIN THE AREA DEFINED AS SCOPE OF WORK PER THESE PLANS. PROVIDE FIRE
<br />EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR.
<br />19. ALL EMERGENCY LIGHTING SOURCES SHALL EMIT A MINIMUM VALUE OF ONE FOOT CANDLE MEASURED AT FLOOR
<br />LEVEL.
<br />20. PROVIDE EMERGENCY NOTIFICATION SYSTEM FOR THE HEARING AND VISUAL IMPAIRED PER A.D.A.
<br />REQUIREMENTS.
<br />N
<br />N
<br />DATE:
<br />DRAWN:
<br />REVIEWED:
<br />PROJECT NO:
<br />SCALE:
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF
<br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED
<br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION,
<br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN
<br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />SHEET TITLE:
<br />SHEET NO:
<br />SEAL AND STAMP:
<br />CONSULTANTS:
<br />PROJECT:
<br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO -
<br />NEW JERSEY - NEW YORK
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />515 South Flower Street, Suite 1200
<br />Los Angeles, CA 90071
<br />T 310.553.3252
<br />T 949.724.8958
<br />T 213.929.1400
<br />DRAWINGS ISSUE
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />T 848.200.1200
<br />711 3rd Ave., 6th Floor
<br />New York, NY 10017
<br />T 917.512.6688
<br />www.saaia.com
<br />T 415.390.6793
<br />NOT FOR CONSTRUCTION
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE
<br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE
<br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH
<br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE
<br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY
<br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING
<br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT
<br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY
<br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF
<br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF
<br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO
<br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE
<br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO
<br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT,
<br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />575 Market Street, #502
<br />San Francisco, CA 94105
<br />As indicated
<br />A-0.1
<br />04/10/24
<br />AW
<br />JN/MP
<br />634495
<br />ABBREVIATION, NOTES,
<br />SYMBOLS, INDEX, MAP,
<br />BUILDING DATA, ETC.
<br />X ENGINEERING
<br />6 E HUTTON CENTRE
<br />DRIVE
<br />SANTA ANA, CA 92707
<br />SUITE 650 EXPANSION
<br />DATE:
<br />DRAWN:
<br />REVIEWED:
<br />PROJECT NO:
<br />SCALE:
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF
<br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED
<br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION,
<br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN
<br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />SHEET TITLE:
<br />SHEET NO:
<br />SEAL AND STAMP:
<br />CONSULTANTS:
<br />PROJECT:
<br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO -
<br />NEW JERSEY - NEW YORK
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />515 South Flower Street, Suite 1200
<br />Los Angeles, CA 90071
<br />T 310.553.3252
<br />T 949.724.8958
<br />T 213.929.1400
<br />DRAWINGS ISSUE
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />T 848.200.1200
<br />711 3rd Ave., 6th Floor
<br />New York, NY 10017
<br />T 917.512.6688
<br />www.saaia.com
<br />T 415.390.6793
<br />NOT FOR CONSTRUCTION
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE
<br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE
<br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH
<br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE
<br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY
<br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING
<br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT
<br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY
<br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF
<br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF
<br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO
<br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE
<br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO
<br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT,
<br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />575 Market Street, #502
<br />San Francisco, CA 94105
<br />As indicated
<br />A-0.1
<br />04/10/24
<br />AW
<br />JN/MP
<br />634495
<br />ABBREVIATION, NOTES,
<br />SYMBOLS, INDEX, MAP,
<br />BUILDING DATA, ETC.
<br />X ENGINEERING
<br />6 E HUTTON CENTRE
<br />DRIVE
<br />SANTA ANA, CA 92707
<br />SUITE 650 EXPANSION
<br />DATE DESCRIPTION DELTA
<br />04/16/24 ISSUE FOR ENGINEERING
<br />05/08/24 TENANT REVISION
<br />05/20/24 ISSUE FOR PLAN CHECK
<br />08/07/24.PCC 01 A
<br />DATE DESCRIPTION DELTA
<br />04/16/24 ISSUE FOR ENGINEERING
<br />05/08/24 TENANT REVISION
<br />05/20/24 ISSUE FOR PLAN CHECK
<br />08/07/24. PCC 01 A
<br />AREA NOT IN CONTRACT, (N.I.C.)
<br />SUITE 650
<br />SUITE 600
<br />NOTES FOR CONTRACTOR BIDS
<br />ALL NOISY WORK TO BE COMPLETED AFTER HOURS AS SUITE IS CURRENTLY OCCUPIED.
<br />PROVIDE ALTERNATE BID FOR ALL WORK TO BE AFTER HOURS.
<br />CONSTRUCTION DOCUMENT APPROVAL
<br />PLEASE REVIEW THE LOCATIONS AND NOTATION OF ALL CONSTRUCTION ITEMS ADDRESSED ON THIS PLAN INCLUDING,
<br />BUT NOT LIMITED TO PARTITIONS, DOORS, GLASS, ELECTRICAL AND TELEPHONE OUTLETS, PLUMBING FIXTURES,
<br />MILLWORK, AND ANY OTHER SPECIALITY CONSTRUCTION ITEMS. SUBSEQUENT REVISIONS MAY RESULT IN ADDITIONAL
<br />FEES INCURRED BY THE TENANT, INCLUDING, BUT NOT LIMITED TO CONSTRUCTION COSTS, DESIGN FEES/PERMIT AND
<br />SUBSEQUENT EXTENSION OF THE CONSTRUCTOIN COMPLETION DATE.
<br />BY SIGNING THE FOLLOWING, TENANT ACKNOLWEDGES AND AGREES WITH THE FOLLOWING:
<br />1) PLEASE INITIAL (AS APPROVED) EACH OF THE FOLLOWING,
<br /> THERE ARE NO ADDITIONAL / SPECIAL THERMOSTATIC OR HVAC NEEDS
<br /> THERE ARE NO ADDITIONAL PLUMBING NEEDS
<br /> THERE ARE NO ADDITIONAL / SPECIAL ELECTRICAL NEEDS
<br /> THERE ARE NO ADDITIONAL / SPECIAL LIGHTING NEEDS
<br /> THERE ARE NO ADDITIONAL / SPECIAL STRUCTURAL NEEDS
<br /> THE TENANT ACKNOWLEDGES AND ACCEPTS COST ASSOCIATED WITH ABOVE STANDARD ITEMS.
<br />2) PLEASE LIST ANY ADDITIONAL REQUIREMENTS BELOW.
<br />COMPANY:
<br />NAME:
<br />TITLE:
<br />DATE:
<br />SUITE 625
<br />CONSTRUCTION MANAGER:
<br />BARKER PACIFIC GROUP
<br />626 WILSHIRE BLVD. SUITE 200
<br />LOS ANGELES, CA 90017
<br />CONTACT: MARK MORENO
<br />EMAIL: MMORENO@BARKERPACIFIC.COM
<br />PHONE: 213-416-7533
<br />A
<br />NELSON
<br />ALGAZE
<br />No. C-21090
<br />REN. 03/31/2025L,CEN S E ARC
<br />,
<br />E
<br />CSAE O CA L ,O RN,ABldg# 101119634-35
<br />
<br />APPROVALS:
<br />PLNG - MKilroy
<br />BLDG - WLee
<br />POLICE - BMartin
<br />6 E Hutton Center Dr
<br />Unit# 625 & 6509/23/2024
|