Laserfiche WebLink
6"MIN. CLR.THERMOSTAT <br />1'-6"ELECT. WALL OUTLET <br />44" A.F.F. TO TOP OF BOXDOOR HANDLE <br />6" +80" TO 96" A.F.F. WALL MOUNTED F.L.S. <br />STROBE DEVICE <br />NOTES: <br />1. ALL VERTICAL DIMENSIONS ARE <br />SHOWN FROM THE FINISH FLOOR TO <br />LOCATION SHOWN. <br />2. THE THERMOSTAT AND CARD <br />READERS SHALL BE LOCATED <br />SO THAT THE TOP OF THE OUTLET <br />BOX IS NO MORE THAT 48" NOR <br />LESS THAN 15" TO THE BOTTOM <br />OF THE OUTLET BOX ABOVE THE <br />FINISHED FLOOR (2022 CBC 11B-308.2.1) <br />3. DIMENSIONS SHOWN ARE FOR <br />REFERENCE USE ONLY. FINAL LOCATION OF <br />OUTLETS AND EQUIPMENT TO BE <br />APPROVED BY SAA AND/OR TENANT. <br />MILLWORK MOUNTING HEIGHTS <br />CERTAIN ELEVATION DIMENSIONS ARE <br />ASSOCIATED WITH CODE REQUIRED <br />MAXIMUM OR MINIMUM MOUNTING <br />HEIGHTS. SUCH DIMENSIONS SHOULD BE <br />HELD DESPITE VARIATIONS IN THE <br />SLAB. CODE DIMENSIONS ARE IN <br />PARENTHESIS WITH AN ASTERISK NEXT TO <br />THE CRITICAL DIMENSION. E.G.: (*+15" <br />MIN.) <br />CONTROL ELEVATIONS ARE COMPRISED OF: <br />FINISH CEILING LEVEL (FCL) <br />FINISH FLOOR LEVEL (FFL) <br />TOP OF SLAB (TOS) <br />ALL DIMENSIONS GIVEN ARE FROM FFL <br />DATUM. FINISH FLOOR MATERIAL IS <br />ASSUMED TO BE 3/8" THICK GLUE <br />DOWN CARPET. FLOOR FINISH AND <br />THICKNESS WILL VARY FROM <br />LOCATION TO LOCATION. REFER TO <br />PLANS AND DETAILS FOR SPECIFIC <br />FLOORING INFORMATION. <br />NO ALLOWANCE HAS BEEN MADE FOR <br />ANY DEPRESSIONS OR ELEVATIONS IN <br />THE SLAB. ELEVATION HEIGHTS <br />SHOULD TAKE INTO ACCOUNT ANY <br />VARIATIONS IN THE FLOOR SLAB. <br />ELECTRICAL MOUNTING HEIGHTS <br />CONTROL ELEVATIONS <br />KEY CARD READER <br />CLG. HT. <br />+60" <br />BOT. OF CASEWORK OVHDS. <br />(* +2'-10" MAX.) <br />COUNTER +2'-10" <br />+2'-6" <br />MILLWORK DESK <br />TYP. J-BOX OUTLET +18"* <br />COAT CLOSET SHELF +48" <br />+34"-44" <br />DOOR HANDLE <br />FIN. FLR. <br />6" <br />FIRE EXTINGUISHER CABINET, SEE A2.0 <br />FOR TYPE. PAINT CABINET TO <br />MATCH ADJACENT WALL. PROVIDE <br />NEW FIRE EXTINGUISHER SUSPENDED IN <br />CABINET <br />TOP OF BOX <br />CL <br />CL <br />CL <br />WALL SWITCH, DIMMER OR WALL <br />MOUNTED MOTION SENSOR, WALL <br />PHONES AND "J" BOXES AT <br />COUNTERS. <br />0'-0" <br />J BOX AT DESK +21" <br />3 <br />CLOSE <br />STOP <br />OPEN <br />B <br />4 <br />2*1 <br />ALARM <br />S <br />3 LC <br />LC <br />L C <br />LC <br />LC <br />RAIL4'-0"EMERG. TEL.CONTROL PANEL <br />SEE BELOW 6'-0" TO 6'-6"PHOTOELECTRIC TUBEBYPASS SWITCH32"1 1/2"MIN.5'-0"6'-0" MIN.3'-6"4'-3" MIN.4'-6" MIN. 42" <br />MIN. <br />6'-8" MIN.4'-0" MAX.3/8" MIN. SEPARATION3/4"2'-11" MIN. A.F.F. ELEVATOR SIGNAGE <br />IDENTIFICATION FOR THE VISUALLY IMPAIRED SHALL BE AS FOLLOWS PASSENGER ELEVATOR CONTROLS SHALL HAVE A <br />MINIMUM DIMENSION OF 3/4 INCHES AND SHALL BE RAISED 1/8 INCH PLUS OR MINUS 1/32 ABOVE THE SURROUNDING <br />SURFACE. CONTROL BUTTONS SHALL HAVE SQUARE SHOULDERS, AND SHALL BE ACTIVATED BY MECHANICAL MOTION <br />WHICH IS DETECTABLE. ALL CONTROL BUTTONS SHALL BE DESIGNATED BY A 5/8 INCH MINIMUM., ARABIC NUMERAL, <br />STANDARD ALPHABET CHARACTER, OR STANDARD SYMBOL IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON. A <br />BRAILLE SYMBOL SHALL BE LOCATED IMMEDIATELY BELOW THE NUMERAL, CHARACTER, OR STANDARD SYMBOL. A <br />MINIMUM CLEARANCE OF 3/8 INCH OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF <br />CONTROL BUTTONS. NOTE. SEE FIGURE BELOW. THEN RAISED CHARACTERS SHALL BE WHITE ON BLACK BACKGROUND. <br />CONTROLS AND EMERGENCY EQUIPMENT IDENTIFIED BY RAISED SYMBOLS SHALL INCLUDE, BUT NOT BE LIMITED TO DOOR <br />OPEN, DOOR CLOSED, ALARM BELL EMERGENCY STOP, AND TELEPHONES. PASSENGER ELEVATOR LANDING JAMBS ON ALL <br />ELEVATOR FLOORS, SHALL HAVE THE NUMBER OF THE FLOOR ON WHICH THE JAMB IS LOCATED DESIGNATED BY RAISED <br />ARABIC NUMERALS WHICH ARE A MINIMUM OF 2 INCHES IN HEIGHT AND RAISED BRAILLE SYMBOLS TO BE LOCATED <br />APPROXIMATELY 5 FEET ABOVE THE FLOOR ON THE JAMB PANELS ON BOTH SIDES OF THE DOOR SO THAT THEY ARE <br />VISIBLE FROM WITHIN THE ELEVATOR. RAISED BRAILLE SYMBOLS SHALL BE PLACED DIRECTLY TO THE LEFT OF THE <br />CORRESPONDING RAISED ARABIC NUMERALS. THE RAISED CHARACTERS SHALL BE ON A CONTRASTING BACKGROUND. <br />GENERAL NOTE: <br />PASSENGER ELEVATORS SHALL BE ACCESSIBLE. <br />ELEVATORS REQUIRED TO BE ACCESSIBLE <br />SHALL BE DESIGNATED AND CONSTRUCTED <br />TO COMPLY WITH CBC 2022 SECTION 11B-407 <br />AND WITH ASME A17.1, SAFETY CODE FOR <br />ELEVATORS AND ESCALATORS. <br />HALL LANTERN <br />FLOOR LANDING ON BOTH SIDES <br />CALL BUTTON <br />42" <br />MIN. <br />GRAB BAR <br />CENTER OPENING DOOR <br />ELEVATOR CONTROL PANEL <br />ELEVATOR EXTERIOR ELEVATION <br />ELEVATOR INTERIOR ELEVATION <br />5'-8" MIN. <br />3'-0" <br />MIN.4'-3" MIN.4'-6" MIN.GRAB BAR <br />SIDE OPENING DOOR <br />5/8" MIN. CHARACTERS <br />AND SYMBOLS HEIGHT <br />PLACE STAR ALONGSIDE <br />MAIN EXIST FLOOR <br />NUMBER <br />AA <br />1 <br />COLUMN GRID <br />LINES <br />0'-0" <br />LEVEL 1 VERTICAL ELEVATION <br />FIRST FLOOR <br />EL. 0'-0" <br />DATUM POINT <br />SPOT ELEVATION <br />A-100 <br />1 <br />SHEET NUMBER <br />PLAN OR DETAIL <br />DESIGNATION <br />A-100 <br />1 <br />SHEET NUMBER <br />VIEW DIRECTION <br />WALL/DETAIL <br />SECTION <br />DESIGNATION <br />A-502 <br />1 <br />2 <br />3 <br />4 <br />SHEET NUMBER <br />INTERIOR <br />ELEVATION <br />DESIGNATION <br />A-100 <br />1 <br />SHEET NUMBER <br />VIEW DIRECTION <br />WALL/DETAIL <br />SECTION <br />DESIGNATION <br />NORTH ARROW <br />3 <br />REVISION NUMBER <br />AREA OF REVISION <br />AREA NOT IN CONTRACT <br />(NIC) <br />BREAK LINE <br />MATCH LINE <br />SEE XX/X-XXX <br />SHEET NUMBER ON <br />WHICH CONTINUATION <br />IS FOUND <br />45925C EQUIPMENT AND <br />FURNITURE TAG <br />ALIGN SURFACES <br />SITE LOCATION <br />SHEET NUMBER SHEET NAME <br />ARCHITECTURE <br />A-0.1 ABBREVIATION, NOTES, SYMBOLS, INDEX, MAP, BUILDING DATA, ETC. <br />A-0.2 GENERAL NOTES <br />A-0.3 GENERAL NOTES AND SPECIFICATIONS <br />A-0.5A SITE PLAN AND ACCESSIBILITY PATH OF TRAVEL <br />A-0.5B SITE PLAN AND ACCESSIBILITY PATH OF TRAVEL <br />A-0.5C EXIT ROUTES AND TACTILE SIGNAGE <br />A-0.5D EXISTING & PROPOSED 6TH FLOOR PLAN <br />A-0.6A BASE BUILDING ACCESSIBILITY <br />A-0.6B BASE BUILDING ACCESSIBILITY <br />A-0.7 BASE BUILDING RESTROOM ACCESSIBILITY PLANS <br />A-1.0 DEMOLITION PLAN <br />A-1.1 CEILING DEMOLITION PLAN <br />A-2.0 CONSTRUCTION PLAN <br />A-3.0 POWER / VOICE / DATA PLAN <br />A-4.0 REFLECTED CEILING PLAN <br />A-5.0 FINISH PLAN <br />A-20.0 INTERIOR ELEVATIONS <br />A-30.0 WALL PARTITION AND HEAD DETAILS <br />A-30.2 CEILING DETAILS <br />A-30.4 GLASS PARTITION DETAILS <br />A-30.5 MILLWORK DETAILS WITH TAB PULLS <br />ELECTRICAL <br />E-1 ELECTRICAL COVER SHEET <br />E-2 GENERAL ELECTRICAL SPECIFICATIONS PART 1 OF 2 <br />E-3 GENERAL ELECTRICAL SPECIFICATIONS PART 2 OF 2 <br />E-4.1 TITLE 24 ENERGY CALCULATIONS <br />E-4.2 TITLE 24 ENERGY ELC FORMS <br />E-5.1 ELECTRICAL LIGHTING PLAN <br />E-5.2 EMERGENCY FOOTCANDLE CALCULATIONS <br />E-6 ELECTRICAL POWER PLAN <br />E-7 PANEL SCHEDULES <br />E-8 TYPICAL LIGHTING CONTROLS DIAGRAMS (WATTSTOPPER) <br />E-9 ELECTRICAL DETAILS <br />MECHANICAL <br />M-1 HVAC NOTES & DETAILS <br />M-2 HVAC PLAN <br />M-3 HVAC TITLE 24 <br />PLUMBING <br />P-1.1 PLUMBING COVER SHEET <br />P-1.2 PLUMBING TITLE 24 & DETAILS <br />P-2 PLUMBING PLAN <br />P-3 PLUMBING SPECIFICATION <br />STRUCTURAL <br />S1.1 GENERAL NOTES <br />S1.2 TYPICAL DETAILS <br />S1.2 .1 TYPICAL DETAILS <br />S2.2 7TH FLOOR FRAMING <br />S2.2A 7TH FLOOR FRAMING PLAN (UNISTRUT OPTION ALTERNATIVE) <br />1. BUILDING PERMIT INFORMATION <br />BUILDING 6 E HUTTON CENTRE DRIVE <br />ADDRESS:SANTA ANA, CA 92707 <br />BUILDING OWNER:KB BPG GRIFFEN TOWERS, LLC <br />5 & 6 HUTTON CENTRE DRIVE <br />SANTA ANA, CA 92707 <br />CONTACT: WILL DICKINSON <br />EMAIL: WDICKINSON@BARKERPACIFIC.COM <br />CONSTRUCTION TYPE:I-A <br />OCCUPANCY:B-OFFICE <br />SPRINKLER BUILDING:FULLY SPRINKLERED <br />NUMBER OF FLOORS:13 <br />TOTAL FLOOR AREA:21,932 SQ. FT. <br />AREA OF WORK:±8,070 SQ. FT. <br />SCOPE OF WORK: TENANT IMPROVEMENT WORK ON ±8,070 SQ. FT. OF THE TOTAL 6TH FLOOR AREA. <br />EXPANSION OF EXISTING SUITE 650 CHANGE FROM ±4,556 SQ. FT. TO ±8,070 SQ. FT. <br />WITH NEW DEMISING WALL. EXISTING SUITE 625 CHANGED FROM ±6,865 SQ. FT. TO <br />±3,597 SQ. FT. WITH NEW DEMISING WALL. NEW WALL, POWER, LIGHTING AND FINISHES. <br />2. C.E.C. TITLE 24/DISABLE ACCESS COMPLIANCE <br />THE PROJECT SHALL COMPLY WITH CCR TITLE 24 (PART 6 - CALIFORNIA ENERGY CODE) FOR ENERGY COMPLIANCE <br />AND THE AMERICANS WITH DISABILITIES ACT (ADA) FOR DISABLED ACCESS REQUIREMENTS. <br />3. EXISTING LIFE-SAFETY SYSTEMS TO BE MODIFIED <br />EXISTING FIRE/LIFE SAFETY SYSTEM IS TO BE MODIFIED TO COMPLY TO CURRENT FIRE/LIFE SAFETY STANDARDS. <br />REFER TO ELECTRICAL ENGINEER DRAWING FOR SCOPE OF WORK. <br />4. CODE COMPLIANCE <br />THE PROJECT SHALL COMPLY WITH CODES, ORDINANCES, OR LAWS HAVING JURISDICTION ON THE PROJECT. <br />WHICH INCLUDE, BUT ARE NOT LIMITED TO: <br />2022 CALIFORNIA BUILDING CODE - ( PART 2, TITLE 24, CCR ) <br />2022 CALIFORNIA ELECTRICAL CODE- ( PART 3, TITLE 24, CCR ) <br />2022 CALIFORNIA MECHANICAL CODE- ( PART 4, TITLE 24, CCR ) <br />2022 CALIFORNIA PLUMBING CODE- ( PART 5, TITLE 24, CCR ) <br />2022 CALIFORNIA FIRE CODE- (PART 9, TITLE 24, CCR ) <br />2022 CALIFORNIA BUILDING STANDARDS CODE ( PART 12, TITLE 24, CCR ) <br />AMERICANS WITH DISABILITIES ACT (ADA) <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN) <br />SANTA ANA MUNICIPAL CODE <br />5. SEPARATE PERMITS <br />PROVIDE SEPARATE PERMITS FOR THE ELECTRICAL, MECHANICAL, PLUMBING, SIGNS, <br />FIRE SPRINKLER AND FIRE PROTECTION. <br />ELEVATOR MOUNTING HEIGHTS <br />AREA OF WORK <br />ELEVATOR MOUNTING HEIGHTS <br />ARCHITECT: <br />SAA INTERIORS + ARCHITECTURE <br />18600 MACARTHUR BLVD. SUITE 100 <br />IRVINE, CA 92612 <br />PHONE: 949-724-8959 <br />DIRECT: 949-608-3748 <br />CONTACT: MICHAEL PARR <br />EMAIL: MPARR@SAAIA.COM <br />STRUCTURAL ENGINEER: <br />MELQART, INC. <br />714 W OLYMPIC BLVD., SUITE 617 <br />LOS ANGELES, CA 90015 <br />PHONE: 213-590-6119 <br />CELL: 909-374-4339 <br />CONTACT: RICHARD DAOUD <br />EMAIL: RICHARD.DAOUD@MELQARTINC.COM <br />MECHANICAL ENGINEER: <br />ENGINEERED SPACES, INC. <br />333 CITY BLVD. WEST, SUITE 300 <br />ORANGE, CA 92868 <br />PHONE: 714- 449-1646 <br />CELL: 949-290-8487 <br />CONTACT: SORIN A. BRIE <br />EMAIL: SORINBRIE@ESI-ENG.COM <br />PLUMBING ENGINEER: <br />ENGINEERED SPACES, INC. <br />333 CITY BLVD. WEST, SUITE 300 <br />ORANGE, CA 92868 <br />PHONE: 714- 449-1646 <br />CELL: 949-290-8487 <br />CONTACT: SORIN A. BRIE <br />EMAIL: SORINBRIE@ESI-ENG.COM <br />ELECTRICAL ENGINEER: <br />ENGINEERED SPACES, INC. <br />333 CITY BLVD. WEST, SUITE 300 <br />ORANGE, CA 92868 <br />PHONE: 714- 449-1646 <br />CELL: 949-290-8487 <br />CONTACT: SORIN A. BRIE <br />EMAIL: SORINBRIE@ESI-ENG.COM <br />CONTACT DIRECTORY PROJECT INFORMATION DRAWING INDEXFIRE PREVENTIONGENERAL DIRECTORY <br />TYPICAL MOUNTING VICINITY MAPDRAFTING CONVENTION <br />KEYPLANDRAFTING CONVENTION NOTES <br />CLIENT: <br />KB BPG GRIFFEN TOWERS, LLC <br />5 & 6 HUTTON CENTRE DRIVE <br />SANTA ANA, CA 92707 <br />CONTACT: WILL DICKINSON <br />EMAIL: WDICKINSON@BARKERPACIFIC.COM <br />6 E HUTTON CENTRE DR. <br />SUITE 650 <br />SANTA ANA, CA 92707 <br />1. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS TAKE PRECEDENCE OVER <br />ALL. NOTIFY ARCHITECT OF CONFLICTS OR DISCREPANCIES IN WRITING. <br />2. DIMENSION CONVENTIONS: <br />a) HORIZONTAL DIMENSIONS ARE SHOWN FROM FACE OF FINISH, UNLESS OTHERWISE NOTED. <br />b) DIMENSIONS NOTED "CLEAR" OR "CLR." MUST BE PRECISELY MAINTAINED: ALLOWING FOR THICKNESS OR <br />MATERIALS. <br />c) DIMENSIONS ARE NOT ADJUSTABLE WITHOUT ARCHITECT'S APPROVAL, UNLESS NOTED. <br />d) DIMENSIONS TO EXTERIOR WINDOW WALL ARE TO INSIDE FINISHED FACE OF THE WALL, UNLESS OTHERWISE <br />NOTED. <br />e) DIMENSIONS TO EXTERIOR GLAZING ARE TO THE INSIDE FACE OF THE EXTERIOR GLAZING. <br />f) VERTICAL DIMENSIONS ARE FROM THE TOP OF THE FINISHED FLOOR, UNLESS OTHERWISE NOTED. <br />g) DO NOTE SCALE DRAWINGS. IF ANY ITEM OF WORK CANNOT BE LOCATED, DO NOT PROCEED WITH THE WORK <br />BEFORE CLARIFYING WITH ARCHITECT. <br />h) VERIFY DIMENSIONS MARKED "V.I.F." PRIOR TO START OF CONSTRUCTION. REPORT INCONSISTENCIES TO <br />ARCHITECT. <br />3. DEFINITION OF TERMINOLOGY: <br />i) "TYPICAL" MEANS IDENTICAL FOR ALL CONDITIONS, UNLESS OTHERWISE NOTED. <br />j) "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. VERIFY DIMENSIONS AND <br />ORIENTATION ON PLANS AND ELEVATIONS. <br />k) "PROVIDE" MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE. <br />l) "FURNISH" MEANS FURNISH ONLY, INSTALLATION BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. <br />m) "INSTALL" MEANS PUT INTO PLACE, SUPPLIED BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. <br />n) "ALIGN" MEANS ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE. <br />LTG LIGHTING <br />LTWT LIGHT WEIGHT <br />LIN LINEAR <br />LONG LONGITUDINAL <br />LP LOW POINT <br />LVR LOUVER <br />MAX MAXIMUM <br />MDF MEDIUM DENSITY FIBERBOARD <br />MECH MECHANICAL <br />MED MEDIUM <br />MEMB MEMBRANE <br />MET METAL <br />MEZZ MEZZANINE <br />MFR MANUFACTURER <br />MIC MICROWAVE <br />MIN MINIMUM <br />MIR MIRROR <br />MISC MISCELLANEOUS <br />MUL MULLION <br />MAINT MAINTENANCE <br />MSTC MASTIC <br />MATL MATERIAL <br />MT METAL THRESHOLD <br />MLDG MOLDING <br />MTD MOUNTED <br />N NORTH <br />N NEW <br />NAT NATURAL <br />NIC NOT IN CONTRACT <br />NO NUMBER <br />NUM NOMINAL <br />NRC NOISE REDUCTION COEFFICIENT <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER DIMENSION <br />OFCI OWNER FURNISHED <br />CONTRACTOR INSTALLED <br />OH OPPOSITE HAND <br />OPNG OPENING <br />OVHD OVERHEAD <br />OFF OFFICE <br />OFOI OWNER FURNISHED <br />OWNER INSTALLED <br />P PAINT <br />PAR PARALLEL <br />PBD PARTICLE BOARD <br />PC PERSONAL COMPUTER <br />PC PIECE <br />PERP PERPENDICULAR <br />PL PLATE <br />PLAM PLASTIC LAMINATE <br />PLYWD PLYWOOD <br />PNL PANEL <br />POL POLISH <br />PR PAIR <br />PTN PARTITION <br />PTD PAPER TOWEL DISPENSER <br />PTDR PAPER TOWEL DISPENSER <br />RECEPTACLE <br />PTR PAPER TOWEL RECEPTACLE <br />PLBG PLUMBING <br />PT POINT <br />LBS POUNDS <br />PSF POUND SQUARE FOOT <br />PSI POUND SQUARE INCH <br />PRCST PRECAST <br />PREFAB PREFABRICATED <br />PROJ PROJECTION <br />QTY QUANTITY <br />QUAL QUALITY <br />QT QUARRY TILE <br />QTRS QUARTERS <br />R RELOCATED <br />RA RETURN AIR <br />RAD RADIUS <br />RB RESILIENT BASE <br />REBAR REINFORCING BAR <br />REF REFERENCE <br />REFL REFLECTED <br />REFR REFRIGERATOR <br />REINF REINFORCED <br />REQ REQUIRED <br />RESIL RESILIENT <br />REV REVISION/ REVISED <br />RH RIGHT HAND <br />RM ROOM <br />RO ROUGH OPENING <br />RT RESILIENT TILE <br />RB RUBBER BASE <br />S SOUTH <br />SA SUPPLY AIR <br />SC SOLID CORE <br />SCH SCHEDULE <br />SFEC SEMI-RECESSED FIRE <br />EXTINGUISHER CABINET <br />SHT SHEET <br />SIM SIMILAR <br />SK SINK <br />SMD SEE MECHANICAL <br />SND SANITARY NAPKIN DISPENSER <br />SNR SANITARY NAPKIN RECEPTACLE <br />SPD SEE PLUMBING DRAWINGS <br />SPEC SPECIFICATION (S) <br />SPKR SPEAKER <br />SQ SQUARE <br />SSD SEE STRUCTURAL DRAWINGS <br />STD STANDARD <br />STL STEEL <br />STOR STORAGE <br />STRL STRUCTURAL <br />SUR SURFACE <br />SUSP SUSPENDED <br />SYM SYMMETRICAL <br />SYS SYSTEM <br />SCD SEAT COVER DISPENSER <br />SECT SECTION <br />SSK SERVICE SINK <br />SD SOAP DISPENSER <br />STA STATION <br />T TREAD <br />TAN TANGENT <br />TBD TO BE DETERMINED <br />TEL TELEPHONE <br />TEMP TEMPERED <br />THRES THRESHOLD <br />TO TOP OF <br />TPD TOILET PAPER DISPENSER <br />TV TELEVISION <br />TYP TYPICAL <br />TEMP TEMPERATURE <br />TER TERRAZZO <br />TOC TOP OF CONCRETE <br />TC TOP OF CURB <br />TOS TOP OF STEEL <br />TS TUBULAR STEEL <br />TW TOP OF WALL <br />TB TOWEL BAR <br />UNF UNFINISHED <br />UON UNLESS OTHERWISE NOTED <br />UR URINAL <br />UTIL UTILITY <br />UL UNDERWRITERS LABORATORY <br />VAR VARIABLE <br />VIF VERIFY IN FIELD <br />VIN VINYL <br />VERT VERTICAL <br />VEST VESTIBULE <br />VCT VINYL COMPOSITION TILE <br />VWC VINYL WALL COVERING <br />WC WALL COVERING <br />WC WATER CLOSET <br />WD WOOD <br />WIN WINDOW <br />WO WHERE OCCURS <br />WP WATERPROOF <br />WPT WORK POINT <br />WR WATER RESISTANT <br />WS WEATHERSTRIPPING <br />WT WEIGHT <br />WDT WIDTH <br />&AND <br /><ANGLE <br />@ AT <br />℄CENTERLINE <br />[CHANNEL <br />DIAMETER OR ROUND <br />'FOOT (FEET) <br />"INCH (INCHES) <br />PERPENDICULAR <br /># POUND OR NUMBER <br />SQUARE FOOT (FEET) <br />ABV ABOVE <br />A/C AIR CONDITIONING <br />ACC ACCESS <br />ACT ACOUSTIC TILE <br />ADJ ADJUSTABLE <br />AFF ABOVE FINISHED FLOOR <br />AL ACTIVE LEAF <br />ALUM ALUMINUM <br />ALT ALTERNATE <br />AP ACCESS PANEL <br />APPV APPROVED <br />ARCH ARCHITECTURAL <br />AUTO AUTOMATIC <br />AVG AVERAGE <br />BD BOARD <br />BATT INSUL BATTING INSULATION <br />BKG BACKING <br />BLDG BUILDING <br />BLKG BLOCKING <br />BM BEAM <br />BOW BACK OF WALL <br />BOT BOTTOM <br />BRKT BRACKET <br />CAB CABINET <br />CLG CEILING <br />CLKG CAULKING <br />CLO CLOSET <br />CLR CLEAR <br />COL COLUMN <br />CONC CONCRETE <br />CONF CONFERENCE <br />CONN CONNECTION <br />CONSTR CONSTRUCTION <br />CONT CONTINUOUS <br />CORR CORRIDOR <br />CPT CARPET <br />CSMT CASEMENT <br />CT CERAMIC TILE <br />CTR CENTER <br />CWK CASEWORK <br />CFCI CONTRACTOR FURNISHED <br />CONTRACTOR INSTALLED <br />CJ CONTROL JOINT <br />CNTR COUNTER <br />DBL DOUBLE <br />DEMO DEMOLISH (DEMOLITION) <br />DEPT DEPARTMENT <br />DET DETAIL <br />DF DRINKING FOUNTAIN <br />DIA DIAMETER <br />DIM DIMENSION <br />DISP DISPENSER <br />DIV DIVISION <br />DN DOWN <br />DO DOOR OPENING <br />DR DOOR <br />DW DISH-WASHER <br />DWG DRAWING <br />DWR DRAWER <br />DIAG DIAGONAL <br />E EAST <br />(E) EXISTING <br />EA EACH <br />EL ELEVATION <br />ELEC ELECTRICAL <br />ELEV ELEVATOR <br />EMER EMERGENCY <br />ENCL ENCLOSURE <br />ENG ENGINEER <br />ENT ENTRANCE <br />EQ EQUAL <br />EQPT EQUIPMENT <br />EWC ELECTRIC WATER COOLER <br />EXH EXHAUST <br />EXP EXPANSION <br />EXT EXTERIOR <br />FA FIRE ALARM <br />FDC FIRE DEPARTMENT CONNECTION <br />FDN FOUNDATION <br />FE FIRE EXTINGUISHER <br />FEC FIRE EXTINGUISHER CABINET <br />FF FINISH FACE <br />FHC FIRE HOSE CABINET <br />FIN FINISH <br />FIX FIXTURE <br />FLR FLOOR <br />FLUOR FLUORESCENT <br />FRPF FIREPROOF <br />FR FIRE RESISTANT <br />FRMG FRAMING <br />FS FULL SIZE <br />FT FOOT OR FEET <br />FOC FACE OF CONCRETE <br />FOS FACE OF STUDS <br />FOW FACE OF WALL <br />FES FIRE EXTINGUISHER SURFACE MOUNTED <br />FD FLOOR DRAIN <br />FURR FURRING <br />GB GRAB BAR <br />GD GARBAGE DISPOSAL <br />GEN GENERAL <br />GL GLASS <br />GYP GYPSUM <br />GA GAGE OR GAUGE <br />GALV GALVANIZED <br />G GAS <br />GYP BD GYPSUM WALLBOARD <br />GC GENERAL CONTRACTOR <br />HDCP HANDICAPPED <br />HDF HIGH DENSITY FIBERBOARD <br />HDWD HARDWOOD <br />HDEW HARDWARE <br />HM HOLLOW METAL <br />HO HOLD OPEN <br />HOR HORIZONTAL <br />HR HOUR <br />HT HEIGHT <br />HVAC HEATING VENTING AIR <br />CONDITIONING <br />HW HOT WATER <br />HWH HOT WATER HEATER <br />HDR HANDRAIL <br />HBD HARDBOARD <br />HTR HEATER <br />HT HEIGHT <br />HC HOLLOW CORE <br />HM HOLLOW METAL INSULATED <br />INCL INCLUDING <br />INFO INFORMATION <br />INSUL INSULATION <br />INT INTERIOR <br />INTER INTERMEDIATE <br />IN INCH <br />ID INSIDE DIAMETER <br />IDENT IDENTIFICATION <br />JAN JANITOR <br />JB JUNCTION BOX <br />JT JOINT <br />JST JOIST <br />K KEY <br />KL KEY LOCK <br />KP KICK PLATE <br />KIT KITCHEN <br />LAM LAMINATE <br />LAV LAVATORY <br />LH LEFT HANDED <br />LAB LABORATORY <br />LT LIGHT <br />1. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA OR WHEN <br />SERVING AN OCCUPANT LOAD OF 50 OR MORE. <br />2. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR <br />EFFORT. (2022 CBC 1010.2). <br />3. EXCEPTION: THIS REQUIREMENT SHALL NOT APPLY TO EXTERIOR EXIT DOORS IN A GROUP "B" OCCUPANCY IF <br />THERE IS A VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED <br />WHEN SPACE IS OCCUPIED". THE LETTERS SHALL BE NOT LESS THAN 1 INCH HIGH ON A CONTRASTING <br />BACKGROUND. THE LOCKING DEVICE MUST BE A TYPE THAT WILL BE READILY DISTINGUISHABLE AS LOCKED. <br />4. PANIC HARDWARE, WHEN INSTALLED, SHALL COMPLY WITH ALL APPLICABLE BUILDING CODE REQUIREMENTS. THE <br />ACTIVATING MEMBER SHALL BE MOUNTED AT A HEIGHT OF NOT LESS THAN 34 INCHES NOR MORE THAN 44 <br />INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE <br />DIRECTION OF EXIT TRAVEL. <br />5. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING <br />SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE <br />LESS THAN 1 FOOT-CANDLE (11-LUX) AT THE WALKING SURFACE LEVEL. (2022 CBC 1013.5 AND 1013.6) <br />6. EXIT ILLUMINATION SHALL COMPLY WITH 2022 CBC SECTION 1008 AND 1013. <br />7. EXIT SIGNS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE OTHERWISE NECESSARY TO CLEARLY <br />INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF 50 OR MORE. <br />8. EXCEPTION: MAIN EXTERIOR EXIT DOORS WHICH OBVIOUSLY AND CLEARLY ARE IDENTIFIABLE AS EXITS NEED NOT <br />BE SIGNED WHEN APPROVED BY THE BUILDING OFFICIAL. <br />9. WHEN NECESSARY, THE FINAL LOCATION AND QUANTITY OF EXIT SIGNS SHALL BE DETERMINED BY THE FIRE <br />DEPARTMENT PRIOR TO CONSTRUCTION OF ANY WORK. <br />10. THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYMBOLS ON EXIT SIGN SHALL BE IN HIGH CONTRAST <br />WITH THEIR BACKGROUND (3/4" x 6" LETTERS MIN.) <br />11. ALL RATED CORRIDOR DOORS SHALL HAVE A THRESHOLD WITH A SMOKE AND DRAFT SEAL AT HEAD AND JAMBS. <br />12. INTERIOR WALL AND CEILING FINISHES SHALL BE NON-COMBUSTIBLE OR HAVE A FLAME SPREAD INDEX OF 0 TO 25; <br />SMOKE-DEVELOPED INDEX 0-450. <br />13. ALL DRAPES, HANGING CURTAINS AND OTHER DECORATIVE MATERIALS SHALL BE TREATED AND MAINTAINED IN A <br />FLAME RETARDANT CONDITION. <br />14. FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED WALLS OR CEILING AS <br />PER 2022 CBC SECTION 716. SMOKE DAMPERS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED <br />WALLS OR CEILING AS PER 2022 CBC SECTION 716. <br />15. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM, <br />EXTEND/MODIFY FIRE/LIFE SAFETY SYSTEM AS REQUIRED. <br />16. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM, FIRE <br />SPRINKLER/OR LIFE SAFETY PLANS MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL PRIOR TO <br />BUILDING PERMIT ISSUANCE. <br />17. IF THE BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM OR HAS A FIRE/LIFE SAFETY SYSTEM, FIRE SPRINKLER <br />SYSTEM PLAN MUST BE REVISED AND APPROVED BY THE CITIES FIRE DEPARTMENT PRIOR TO THE INSTALLATION OR <br />MODIFICATION OF SPRINKLER SYSTEMS. <br />18. A PORTABLE FIRE EXTINGUISHER WITH A MINIMUM 2A10BC RATING SHALL BE PROVIDED EVERY 75' OF TRAVEL <br />DISTANCE FROM ANY POINT WITHIN THE AREA DEFINED AS SCOPE OF WORK PER THESE PLANS. PROVIDE FIRE <br />EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. <br />19. ALL EMERGENCY LIGHTING SOURCES SHALL EMIT A MINIMUM VALUE OF ONE FOOT CANDLE MEASURED AT FLOOR <br />LEVEL. <br />20. PROVIDE EMERGENCY NOTIFICATION SYSTEM FOR THE HEARING AND VISUAL IMPAIRED PER A.D.A. <br />REQUIREMENTS. <br />N <br />N <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO - <br />NEW JERSEY - NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-0.1 <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />ABBREVIATION, NOTES, <br />SYMBOLS, INDEX, MAP, <br />BUILDING DATA, ETC. <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO - <br />NEW JERSEY - NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-0.1 <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />ABBREVIATION, NOTES, <br />SYMBOLS, INDEX, MAP, <br />BUILDING DATA, ETC. <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />DATE DESCRIPTION DELTA <br />04/16/24 ISSUE FOR ENGINEERING <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />08/07/24.PCC 01 A <br />DATE DESCRIPTION DELTA <br />04/16/24 ISSUE FOR ENGINEERING <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />08/07/24. PCC 01 A <br />AREA NOT IN CONTRACT, (N.I.C.) <br />SUITE 650 <br />SUITE 600 <br />NOTES FOR CONTRACTOR BIDS <br />ALL NOISY WORK TO BE COMPLETED AFTER HOURS AS SUITE IS CURRENTLY OCCUPIED. <br />PROVIDE ALTERNATE BID FOR ALL WORK TO BE AFTER HOURS. <br />CONSTRUCTION DOCUMENT APPROVAL <br />PLEASE REVIEW THE LOCATIONS AND NOTATION OF ALL CONSTRUCTION ITEMS ADDRESSED ON THIS PLAN INCLUDING, <br />BUT NOT LIMITED TO PARTITIONS, DOORS, GLASS, ELECTRICAL AND TELEPHONE OUTLETS, PLUMBING FIXTURES, <br />MILLWORK, AND ANY OTHER SPECIALITY CONSTRUCTION ITEMS. SUBSEQUENT REVISIONS MAY RESULT IN ADDITIONAL <br />FEES INCURRED BY THE TENANT, INCLUDING, BUT NOT LIMITED TO CONSTRUCTION COSTS, DESIGN FEES/PERMIT AND <br />SUBSEQUENT EXTENSION OF THE CONSTRUCTOIN COMPLETION DATE. <br />BY SIGNING THE FOLLOWING, TENANT ACKNOLWEDGES AND AGREES WITH THE FOLLOWING: <br />1) PLEASE INITIAL (AS APPROVED) EACH OF THE FOLLOWING, <br /> THERE ARE NO ADDITIONAL / SPECIAL THERMOSTATIC OR HVAC NEEDS <br /> THERE ARE NO ADDITIONAL PLUMBING NEEDS <br /> THERE ARE NO ADDITIONAL / SPECIAL ELECTRICAL NEEDS <br /> THERE ARE NO ADDITIONAL / SPECIAL LIGHTING NEEDS <br /> THERE ARE NO ADDITIONAL / SPECIAL STRUCTURAL NEEDS <br /> THE TENANT ACKNOWLEDGES AND ACCEPTS COST ASSOCIATED WITH ABOVE STANDARD ITEMS. <br />2) PLEASE LIST ANY ADDITIONAL REQUIREMENTS BELOW. <br />COMPANY: <br />NAME: <br />TITLE: <br />DATE: <br />SUITE 625 <br />CONSTRUCTION MANAGER: <br />BARKER PACIFIC GROUP <br />626 WILSHIRE BLVD. SUITE 200 <br />LOS ANGELES, CA 90017 <br />CONTACT: MARK MORENO <br />EMAIL: MMORENO@BARKERPACIFIC.COM <br />PHONE: 213-416-7533 <br />A <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025L,CEN S E ARC <br />, <br />E <br />CSAE O CA L ,O RN,ABldg# 101119634-35 <br /> <br />APPROVALS: <br />PLNG - MKilroy <br />BLDG - WLee <br />POLICE - BMartin <br />6 E Hutton Center Dr <br />Unit# 625 & 6509/23/2024