My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 S Virlee St #2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Virlee St
>
906 S Virlee St Unit# 2
>
906 S Virlee St #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2025 8:24:02 AM
Creation date
6/10/2025 8:23:58 AM
Metadata
Fields
Template:
Plan
Permit Number
101119042
Full Address
906 S Virlee St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ROOF UNDERLAYMENT <br />ROOF SHEATHING <br />INSULATION <br />(IF REQUIRED) <br />CONTINUOUS <br />RIDGE VENT <br />24GA.RIDGE FLASHING <br />UNDERLAYMENT W/ <br />12"MIN. OVERLAP <br />RIDGE BOARD, SEE <br />STRUCTURAL SHEETS <br />EXTERIOR FINISH <br />6" MINAT PAVED8" MIN.SILL PLATE, <br />PRESSURE TREATED <br />2"MIN.26 GAGE WEEP <br />SCREED <br />2 LAYERS 30# FELT OVER <br />PLYWOOD SHEATHING <br />ROOFING <br />ROOF FASCIA <br />2x BLOCK <br />INSULATION <br />FINISH GRADE <br />4'' THICK BASE OF 1/2'' <br />OR LARGER CLEAN <br />AGGREGATE <br />10 ML POLY VAPOR <br />DIFFUSION RETARDER <br />IS EXTENTED UNDER <br />FOOTING <br />PLYWOOD SHEATHING <br />PER STRUCT. MIN 3/8" <br />CDX <br />INTERIOR FINISH <br />2X WALL STUDS <br />CONC. SLAB <br />PLASTER WEEP SCREED 1 <br />2 <br />3 <br />4 <br />5 <br />N.T.S. <br />N.T.S. <br />N.T.S. <br />N.T.S. <br />N.T.S. <br />R-15 INSULATION <br />RIDGE DETAIL <br />ASPHALT SHINGLE, LAND MARK, <br />ICC-ES-ESR-1389 & ESR-3537 <br />NOTE: <br />PROVIDE EITHER 1" MINIMUM CLEARANCE BETWEEN INSULATION <br />AND ROOF SHEATHING OR USE INSULATION BAFFLE FOR RAFTER <br />SPACE VENTILATION <br />ROOF RAFTER, SEE <br />STRUCTURAL SHEETS <br />2 LAYERS 30# FELT OVER <br />PLYWOOD SHEATHING <br />ROOFING <br />2x FLAT OUTRIGGER <br />@24" O.C. <br />DRIP EDGE <br />FLASHING <br />EXTERIOR FINISH <br />EAVE DETAIL <br />GABLE EAVE DETAIL <br />NON BEARING WALL DETAIL <br />2X WALL STUDS <br />EXTERIOR FINISH <br />DBL TOP PLATE <br />2x CEILING JOIST <br />ROOF RAFTER, SEE <br />STRUCTURAL SHEETS <br />ROOF FASCIA <br />2x CEILING JOIST <br />2X WALL STUDS <br />INSULATION <br />ROOF RAFTER, SEE <br />STRUCTURAL SHEETS <br />DBL TOP PLATE <br />2x CEILING JOIST <br />/ TRUSS BOTT. CHORD <br />2x PLATE <br />INTERIOR FINISH <br />TYP. <br />CONC. SLAB <br />2X SILL PLATE, <br />PRESSURE TREATED <br />6N.T.S. <br />ROOF RAFTER, SEE <br />STRUCTURAL SHEETS <br />EAVE FRAMING/ FIRE RATED U.N.O. DETAIL <br />ROOF SHEATHING <br />ROOFING MATERIAL <br />WATER PROTECTION <br />MEMBRANE (ICE DAM <br />PROTECTION WHERE <br />REQ'D) <br />METAL DRIP EDGE <br />5 8" TYPE "X" U.N.O. <br />WHERE 1HR RATED <br />EAVE OCCURS <br />STUCCO <br />2X FASCIA <br />2X DOUBLE <br />TOP PLATE <br />SHEAR WALL WHERE <br />OCCURS ON PLAN <br />18" MIN. <br />U.N.O. <br />STUCCO <br />RADIANT BARRIER <br />PER T24 EMITTANCE <br />OF 0.05 OR LESS <br />INSULATION AS <br />NOTED PER PLAN <br />INSULATION AS <br />NOTED PER PLAN <br />GYPSUM BOARD <br />W/ SEMI-VAPOR <br />PERMEABLE <br />(LATEX) PAINT <br />1. 1-HOUR WALL REQ'D WHERE <5'-0" TO PLATE <br />2. NO OPENINGS ALLOWED IF <3'-0" TO PLATE <br />3. BETWEEN 3'-0" AND 5'-0" WALL AREA CAN HAVE <br />25% MAXIMUM OPENING <br />F.G. <br />5 <br />A3 <br />8"9'-4"1 <br />A3 <br />2x4 @ 16" O.C. <br />R-15 INSULATION, TYP. <br />2-2x4 TOP PL, <br />TYP.5 <br />A3 <br />F.G. <br />7/8" STUCCO FINISH OVER <br />WIRE LATH OVER WEATHER <br />RESISTANT BARRIER <br />2x4 P.T. SILL <br />PLATE, TYP. <br />R-38 INSULATION <br />1/2" GYPSUM BOARD <br />BED #3 LIVING ROOM <br />4" CONC. SLAB, <br />PER STRUCTURAL <br />2 <br />A3 <br />7 <br />A3 <br />12" EAVES <br />(TYP.) <br />2x CEILING JOISTS, <br />PER STRUCTURAL <br />2x ROOF RAFTERS <br />@ 16" O.C. PER <br />STRUCTURAL <br />- ASPHALT ROOF SHINGLES "WEATHER WATCH" <br />ICE & WATER SHIELD AS 30# FELT PAPER <br />MANUFACTURED BY GAF OR EQUAL. INSTALL AS <br />PER MANUFACTURER'S SPECIFICATIONS 1/2" OSB <br />PLYWOOD SHEATHING ( TO MATCH WITHIN <br />EXISTING ROOF/ MATERIAL % COLOR), TYP. <br />COOL ROOF CRRC #0890-0016A <br />ADU CROSS SECTION A-A <br />SCALE: 1/4" = 1' <br />EXTERIOR CONSTRUCTION ASSEMBLY <br />ALL EXTERIOR WALL ASSEMBLIES SHALL INCLUDE: <br />a. TWO LAYERS OF GRADE D OR 60 MINUTE GRADE D PAPER APPLIED OVER ALL <br />WOOD BASE SHEATHING. (CRC R703.7.3 & R703.2). <br />b. A MINIMUM 0.019 INCH (NO. 26 GALVANIZED SHEET GAGE) <br />CORROSION-RESISTANT WEEP SCREED. (CRC 703.1.1 & R703.7.2.1) <br />c. THE SCREED SHALL BE INSTALLED WITH THE WEEP OPENINGS LOCATED A <br />MINIMUM 1 INCH BELOW FOUNDATION PLATE LINE AND 4 INCHES ABOVE <br />FINISH GRADE OR 2-INCHES ABOVE PAVED AREAS. (CRC R703.1.1 & R703.7.2.1) <br />4:124:12 <br />ADU CROSS SECTION B-B <br />SCALE: 1/4" = 1' <br />F.G.F.G. <br />BED #3 BED #2KITCHENGARAGE <br />5 <br />A3 <br />5 <br />A3 <br />5 <br />A3 <br />5 <br />A3 <br />4 <br />A3 <br />7/8" STUCCO FINISH OVER <br />WIRE LATH OVER WEATHER <br />RESISTANT BARRIER <br />2-2x4 TOP PL, <br />TYP. <br />1/2" GYPSUM BOARD R-38 INSULATION <br />2x4 P.T. SILL <br />PLATE, TYP. <br />2x4 P.T. SILL <br />PLATE, TYP. <br />1 <br />A3 <br />8"9'-4"12" EAVES <br />(TYP.) <br />2x4 @ 16" O.C. <br />R-15 INSULATION, TYP. <br />2x ROOF RAFTERS <br />@ 16" O.C. PER <br />STRUCTURAL <br />- ASPHALT ROOF SHINGLES "WEATHER WATCH" <br />ICE & WATER SHIELD AS 30# FELT PAPER <br />MANUFACTURED BY GAF OR EQUAL. INSTALL AS <br />PER MANUFACTURER'S SPECIFICATIONS 1/2" OSB <br />PLYWOOD SHEATHING ( TO MATCH WITHIN <br />EXISTING ROOF/ MATERIAL % COLOR), TYP. <br />COOL ROOF CRRC #0890-0016A <br />4" CONC. SLAB, <br />PER STRUCTURAL <br />4" CONC. SLAB, <br />PER STRUCTURAL <br />2x ROOF RAFTERS <br />@ 16" O.C. PER <br />STRUCTURAL <br />2x4 @ 16" O.C. <br />R-15 INSULATION, TYP. <br />2x CEILING JOISTS, <br />PER STRUCTURAL <br />2-2x4 TOP PL, <br />TYP.34"TYP.34"TYP.1x PLATE <br />2x BLKG @ 48" O.C. <br />W/ (3) 16d's EA. END <br />TRUSS WHERE <br />OCCURS PER PLAN <br />SIMPSON "DTC" <br />@ 48" O.C. MAX <br />SIMPSON "DTC" <br />@ 48" O.C. MAX <br />2 LAYERS 30# FELT OVER <br />PLYWOOD SHEATHING <br />ROOFING <br />2x BLOCK <br />INSULATION <br />7N.T.S.NON-EAVE DETAIL <br />2X WALL STUDS <br />EXTERIOR FINISH <br />DBL TOP PLATE <br />2x CEILING JOIST <br />ROOF RAFTER, SEE <br />STRUCTURAL SHEETS <br />3 <br />A3 <br />NOTES: <br />EXTERIOR BUILDING AND ROOFING MATERIALS <br />SHALL MATCH THAT OF THE EXISTING PRIMARY <br />DWELLING IN TEXTURE, COLOR, AND FINISH. <br />F.G. <br />F.S. <br />F.C. <br />TOP OF ROOF <br />8"9'-4"15'-034"6'-8"F.G. <br />F.S. <br />TOP OF ROOF <br />8"15'-034"6'-8"F.C.9'-4"4:12 <br />F.G. <br />F.S. <br />TOP OF ROOF <br />8"15'-034"6'-8"F.C.9'-4"F.G. <br />F.S. <br />TOP OF ROOF <br />8"15'-034"6'-8"F.C.9'-4"23'-0"4'-0" <br />27'-0" <br />4'-10"50'-0" <br />4'-10"27'-0"13'-0"37'-0" <br />50'-0"31'-10" <br />ADU NORTH ELEVATION <br />SCALE: 1/4" = 1' <br />ADU SOUTH ELEVATION <br />SCALE: 1/4" = 1' <br />ADU EAST ELEVATION <br />SCALE: 1/4" = 1' <br />ADU WEST ELEVATION <br />SCALE: 1/4" = 1' <br />FUTURE SOLAR PANELS <br />(90 SQ.FT.) <br />ASPHALT SHINGLE ROOF TO <br />MATCH EXISTING RESIDENCE <br />ASPHALT SHINGLE ROOF TO <br />MATCH EXISTING RESIDENCE <br />ASPHALT SHINGLE ROOF TO <br />MATCH EXISTING RESIDENCE <br />ASPHALT SHINGLE ROOF TO <br />MATCH EXISTING RESIDENCE4:12 <br />4:12 <br />4:124:12 <br />STUCCO TO MATCH <br />EXISTING RESIDENCE <br />STUCCO TO MATCH <br />EXISTING RESIDENCE <br />STUCCO TO MATCH <br />EXISTING RESIDENCE <br />STUCCO TO MATCH <br />EXISTING RESIDENCE <br />4x4 POST <br />4x4 POST <br />4x4 POST <br />12" EAVES <br />(TYP.) <br />12" EAVES <br />(TYP.) <br />12" EAVES <br />(TYP.) <br />4:124:12 <br />GABLE VENT, TYP. <br />GABLE VENT, TYP. <br />(N) A/C <br />CONDENSER <br />12" EAVES <br />(TYP.) <br />0.32" THICK 3lb/sf BRICK <br />VENEER TO MATCH <br />EXISTING RESIDENCE <br />0.32" THICK 3lb/sf BRICK <br />VENEER TO MATCH <br />EXISTING RESIDENCE <br />(N) WINDOW TRIM <br />TO MATCH (E), TYP. <br />(N) WINDOW TRIM <br />TO MATCH (E), TYP. <br />DELTA <br />CONSTRUCTION CO. <br />SHEET NUMBER <br />ORIGIN DATE: 06/19/2024 <br />DRAWN BY:LD <br />CHECKED BY:EE <br />DINH VU NGODINH <br />NEW DETACHED ADU <br />906 S VIRLEE ST & <br />906 S VIRLEE ST UNIT #2, <br />SANTA ANA, CA 92704 <br />714-200-8872 <br />17266 FLAME TREE CIR, FOUNTAIN <br />VALLEY, CA 92708 <br />VNDINH2003@GMAIL.COM <br />DRAWINGS APPROVED BY:A3 <br />ADU ELEVATIONS, <br />CROSS- SECTION & <br />DETAILS <br />906 S Virlee St & #2 - <br />10111904212/9/2024
The URL can be used to link to this page
Your browser does not support the video tag.