Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1626 @ 2"5206 (3.50")Passed (31%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)1332 @ 1' 2 3/4"4725 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)5255 @ 6' 9 1/2"6768 Passed (78%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.133 @ 6' 9 1/2"0.442 Passed (L/999+)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.235 @ 6' 9 1/2"0.663 Passed (L/676)--1.0 D + 1.0 L (All Spans) <br />System : Floor <br />Member Type : Drop Beam <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Factored Accessories <br />1 - Stud wall - SPF 3.50"3.50"1.50"710 917 1626 Blocking <br />2 - Stud wall - SPF 3.50"3.50"1.50"710 917 1626 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)13' 7" o/c <br />Bottom Edge (Lu)13' 7" o/c <br />Dead Floor Live <br />Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments <br />0 - Self Weight (PLF)0 to 13' 7"N/A 10.0 -- <br />1 - Uniform (PSF)0 to 13' 7" (Front)13' 6"7.0 10.0 Default Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />MEMBER REPORT PASSED <br />Level, Ceiling Flush Beam <br />1 piece(s) 4 x 12 DF No.1 <br />ForteWEB Software Operator Job Notes 12/20/2023 12:58:36 AM UTC <br />Ehab Elias <br />Structural Ventures <br />(760) 484-6343 <br />eliasehab@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: Virlee Beams <br />Page 1 / 1906 S Virlee St & #2 - <br />10111904212/9/2024