Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1282 @ 2"5206 (3.50")Passed (25%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)1065 @ 1' 3/4"3885 Passed (27%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)3821 @ 6' 3 1/2"4991 Passed (77%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.148 @ 6' 3 1/2"0.408 Passed (L/990)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.263 @ 6' 3 1/2"0.613 Passed (L/559)--1.0 D + 1.0 L (All Spans) <br />System : Floor <br />Member Type : Drop Beam <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />All Product Solutions <br />Depth Series Plies Cost Index <br />11 7/8"1 1/4" 1.3E TimberStrand® LSL 1 19.30 * <br />9 1/4"4 x DF No.1 1 55.04 <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />SOLUTIONS REPORT PASSED <br />The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal <br />purposes. <br />Level, Garage Flush Beam <br />Current Solution: 1 piece(s) 4 x 10 DF No.1 <br />ForteWEB Software Operator Job Notes 12/20/2023 1:00:57 AM UTC <br />Ehab Elias <br />Structural Ventures <br />(760) 484-6343 <br />eliasehab@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: Virlee Beams <br />Page 1 / 1906 S Virlee St & #2 - <br />10111904212/9/2024