Laserfiche WebLink
24-8009 <br /> Page 9 <br /> <br />Conformance to the criteria presented in the above table for seismic design does not constitute <br />any type of guarantee or assurance that significant structural damage or ground failure will not <br />occur during a large earthquake event. The intent of the code is “life safety” and not to <br />completely prevent damage of the structure, since such design may be economically prohibitive. <br /> <br />Foundation Design Recommendations <br />The proposed ADU may be supported on continuous and/or spread footings. Bearing capacity <br />recommendations for shallow foundations are presented below. <br /> <br />An allowable bearing pressure of 2000 pounds per square foot may be used in the design. <br />These recommendations assume that footings will be supported on a minimum of three (3) feet <br />of engineered fill. However, deeper fill (as much as 10 feet) may be required due to the <br />presence of the demolished pool, as shown in Plate 1. <br /> <br />The minimum recommended footing depth is 24-inches below the lowest adjacent grade. The <br />minimum recommended footing width is 18 inches for continuous footing and twenty-four (24) <br />inches for pad footings. A minimum reinforcement of 2-No.4 steel bars top and bottom is <br />required for continuous footings from a geotechnical viewpoint. Foundation design details such <br />as concrete strength, reinforcements, etc should be established by the Structural Engineer. <br /> <br />A one-third (1/3) increase on the aforementioned bearing pressure may be used in design for <br />short-term wind or seismic loads. <br /> <br />The static total and differential settlements between adjacent footings supported on competent <br />bedrock are not anticipated to exceed one (1) inch and one-half (0.5) inch over 30 feet, <br />respectively. <br /> <br />All footings should meet the setback requirements presented in 2022 CBC. <br /> <br />Resistance to lateral loads can be assumed to be provided by passive earth pressure and by <br />friction acting on structural components in permanent contact with the subgrade soils. <br /> <br />Lateral resistance on the sides of footings may be computed using a passive pressure of 200 <br />pounds per square foot per foot of embedment, subject to a maximum of 2000 pounds per <br />square foot. An allowable friction coefficient of 0.30 may be assumed with dead load forces <br />between concrete and the supporting soils. Passive pressure and frictional resistance could be <br />combined in determining the total lateral pressure resistance, provided one of them is reduce by <br />50%. <br /> <br />Drilled Piers <br />Alternatively, the proposed ADU may be supported on drilled piers embedded a minimum of 10 <br />feet into competent native soils with a structural floor. The recommended minimum pier <br />diameter is 24-inches. <br /> <br />The drilled piers may be designed for an allowable frictional resistance of 200 pounds per <br />square foot for competent native. The uplift capacity may be taken as one-half of downward <br />capacity plus the weight of the caisson. The lateral capacity may be taken as 200 pounds per <br />square foot per foot of depth (maximum 2,000 psf). The caisson capacity within the <br />2039 N Victoria Drive <br />#24/28/2025