My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
627 S Shelton St Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Shelton St
>
627 S Shelton St Unit# 2
>
627 S Shelton St Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:41:40 PM
Creation date
6/15/2025 12:41:36 PM
Metadata
Fields
Template:
Plan
Permit Number
101120163
Full Address
627 S Shelton St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A.WALK-IN CLOSET WITH AN AREA GREATER THAN 70 FT² WILL BE PROVIDED WITH <br />DIMMER SWITCHES FOR LIGHTING [CRnC 150.0(k)J]. <br />B.OUTDOOR LUMINARIES SHALL BE CONTROLLED BY PHOTOCELL AND MOTION <br />SENSOR, OR OTHER METHOD AS PERMITTED BY [CEnC 150.0(k)3A]. <br />C.CEILING RECESSED LED DOWNLIGHTS SHALL BE REQUIRED TO BE APPENDIX JA8 <br />COMPLIANT [CEnC 150.0(k)1]. <br />D.ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING <br />OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, LIVING ROOMS, <br />BEDROOMS, CLOSETS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE <br />AFCI PROTECTED BY ANY OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). <br />E.IN EACH ATTACHED GARAGE WITH ELECTRIC POWER, AT LEAST ONE RECEPTACLE <br />OUTLET SHALL BE INSTALLED IN EACH VEHICLE BAY AND NOT MORE THAN 1.7 M (5 <br />½ FT.) ABOVE THE FLOOR. CEC 210.52 (G) (1) <br />F.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48” MEASURED FROM <br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />G.DOORBELL CONTROLS TO NOT EXCEED 48” ABOVE EXTERIOR FLOOR, MEASURED <br />FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />H.ALL LIGHTING TO BE HIGH EFFICACY. CENERGYC 150.0(K)1(A). <br />I.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY AN OCCUPANCY <br />OR VACANCY SENSOR. CENC §150.0(K)2I. <br />J.LUMINAIRES THAT ARE OR CONTAIN LIGHT SOURCES THAT MEET REFERENCE JOINT <br />APPENDIX JA8 REQUIREMENTS FOR DIMMING, AND THAT ARE NOT CONTROLLED BY <br />OCCUPANCY OR VACANCY SENSORS MUST HAVE DIMMING CONTROLS EXCEPT IN <br />CLOSETS LESS THAN 70 SQUARE FEET OR HALLWAYS. CENC §150.0(K)2J. <br />K.FOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR LIGHTING PERMANENTLY <br />MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT <br />MUST MEET THE REQUIREMENT IN ITEM A AND THE REQUIREMENTS IN ITEM A AND <br />THE REQUIREMENTS IN EITHER ITEM B OR ITEM C: <br />1.CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT PERMITS THE <br />AUTOMATIC ACTIONS OF ITEMS B OR C BELOW; AND <br />2.CONTROLLED BY PHOTOCELL AND EITHER A MOTION SENSOR OR AN AUTOMATIC <br />TIME SWITCH; OR <br />3.CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL. CENC §150.0(K)3A. <br />L.IN ADDITION TO THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS, AN <br />EXHAUST FAN SHALL BE SIZED TO PROVIDE VENTILATION FOR THE WHOLE HOUSE. <br />THE MINIMUM VENTILATION RATE FOR THE IAQ FAN SHALL BE CALCULATED <br />ACCORDING TO ASHRAE STANDARD 62.2 AND 150.0(o)C / 160.2. ONE OF THE <br />LOCAL EXHAUST FAN IN THE BATHROOMS OF KITCHENS MAY BE USED TO MEET THE <br />WHOLE-BUILDING VENTILATION, PROVIDED THE EXHAUST FAN MEETS THE MINIMUM <br />VENTILATION RATED FOR BOTH THE LOCAL EXHAUST AND IAQ REQUIREMENTS. THE <br />DUCTING FOR THE WHOLE BUILDING EXHAUST FAN SHALL BE SIZED ACCORDING TO <br />TABLE 150.0-H / 160.2-H, AND THIS EXHAUST FAN SHALL OPERATE CONTINUOUSLY. <br />ELECTRICAL LEGEND <br />ELECTRICAL & MECHANICAL NOTES: <br />NEW OUTDOOR CEILING FAN <br />NEW DUPLEX RECEPTACLE WITH GFCI PROTECTION <br />NEW SWITCH <br />"UL LISTED " NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />NEW LED PENDANT LIGHT (HIGH-EFFICACY) <br />NEW SWITCH W/ OCCUPANCY SENSOR <br />NEW AFCI DUPLEX RECEPTACLE OUTLET <br />NEW SWITCH 3 WAY <br />NEW EXTERIOR WATER PROOF OUTLET <br />OS <br />GFCI <br />AFCI <br />3 <br />WP <br />S <br />S <br />S <br />NEW LED WALL MOUNT LIGHT WITH PHOTOCELL SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />NEW SWITCH W/DIMMERD <br />NEW LED WALL MOUNT LIGHT <br />(HIGH-EFFICACY) <br />NEW SWITCH W/ MOTION SENSORMS <br />S <br />PS <br />NEW LED WALL MOUNT LIGHT WITH MOTION SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />S <br />MS <br />NOTE:RECESSED LUMINARIES SHALL FIXTURES BE LISTED <br />FOR ZERO CLEARANCE INSULATION CONTACT (IC) <br />NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS <br />DUCTLESS MINI-SPLIT AIR CONDITIONER INDOOR UNIT WALL MOUNTED <br />CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68° F <br />SEE ADDITIONAL SPECIFICATION IN TITLE REPORT <br />SYMBOL LEGEND <br />REF. <br />ELECTRICAL PLAN1 <br />SCALE: 1/4" = 1'-0" <br />N <br />A SD <br />SDSD <br />CM <br />W&D <br />SHOWER <br />EXISTING GARAGE TO BE CONVERTED INTO AN A.D.U <br />NEW BEDROOM 1 <br />NEW KITCHEN <br />A TYPE 1 CLOTHES DRYER EXHAUST DUCT <br />(MIN. 4" DIA. & 0.016" THICK RIGID METAL) <br />TO THE OUTSIDE OF THE BUILDING AND <br />EQUIPPED WITH A BACK-DRAFT DAMPER <br />SHALL BE PROVIDED. EXHAUST DUCT <br />LENGTH IS LIMITED TO 14'. WITH 2 ELBOWS <br />ASHRAE STANDARD 62.2 TABLE 7.1 <br />PRESCRIPTIVE DUCT SIZING REQUIREMENTS <br />DUCT TYPE FLEX DUCT SMOOTH DUCT <br />FAN RATING CFM <br />@0.25 IN. W.G.50 80 100 125 50 80 100 125 <br />MAXIMUM ALLOWABLE DUCT LENGTH (FT) <br />DIAMETER (IN)FLEX DUCT SMOOTH DUCT <br />3 X X X X 5 X X X <br />4 70 3 X X 105 35 5 X <br />5 NL 70 35 20 NL 135 85 55 <br />6 NL NL 125 95 NL NL NL 145 <br />7 AND ABOVE NL NL NL NL NL NL NL NL <br />THIS TABLE ASSUMES NO ELBOWS. DEDUCT 15 FT. OF ALLOWABLE DUCT LENGHT FOR EACH <br />TURN, ELBOW, OR FITTING. <br />NL= NO LIMIT ON DUCT LENGTH OF THIS SIZE <br />X= NOT ALLOWED, ANY LENGTH OF DUCT OF THIS SIZE WITH ASSUMED TURNS, ELBOWS, <br />FITTINGS WILL EXCEED THE RATED PRESSURE DROP. <br />NE <br />W <br /> <br />M <br />I <br />N <br />I <br />- <br />S <br />P <br />L <br />I <br />T <br />NE <br />W <br /> <br />M <br />I <br />N <br />I <br />- <br />S <br />P <br />L <br />I <br />T <br />NEW TANKLESS W/H <br />NEW MULTI-ZONE MINI-SPLIT <br />OUTDOOR CONDENSER UNIT <br />EXHAUST DUCT TERMINATION <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM <br />OPENINGS INTO THE BUILDING. CMC 504.5 <br />DUCTING FOR EXHAUST FAN SHALL BE <br />SIZED ACCORDING TO ASHRAE STANDARD <br />62.2 TABLE 7.1 <br />EXHAUST DUCT TERMINATION. <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM PROPERTY LINE AND <br />3’-0” FROM OPENINGS INTO THE BUILDING. CMC 504.5 <br />PROVIDE A DEDICATED 125 VOLT, 20 AMP <br />ELECTRICAL GFCI RECEPTACLE CONNECTED TO <br />THE ELECTRICAL PANEL WITH A 120/240 VOLT <br />3 CONDUCTOR 10 AWG COPPER BRANCH <br />CIRCUIT, WITHIN 3 FT OF THE WATER HEATER <br />AND ACCESSIBLE TO THE WATER HEATER <br />WP <br />WP <br />GFCI <br />GFCI <br />GFCI GFCI GFCIGFCI <br />GFCI <br />3DS <br />3DS <br />3DS <br />3DS <br />3DS <br />OS S <br />S <br />S <br />GFCI <br />NEW CLOSET <br />NEW CLOSET <br />3DS <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI AFCI <br />AFCI AFCI <br />AFCI <br />AFCI <br />S <br />PS <br />/ <br />M <br />S <br />NEW BEDROOM 2 <br />S <br />SAFCI <br />NEW BATHROOMEF <br />(E) PROPERTY LINE <br />RH <br />KITCHEN VENTED RANGE HOODS <br />I. HERS VERIFICATION OF AIRFLOW AND SOUND RATINGS. <br />II. MINIMUM AIRFLOW OF 280 CFM (PER TABLE 150.0-G SHEET A-2.4). <br />III. MAXIMUM SONE RATING OF 3.0. <br />TABLE 150.0-G KITCHEN RANGE HOOD AIRFLOW RATES (CFM) <br />AND ASTM E3087 CAPTURE EFFICIENCY (CE) RATINGS <br />ACCORDING TO DWELLING UNIT FLOOR AREA AND KITCHEN <br />RANGE FUEL TYPE <br />DWELLING UNIT FLOOR <br />AREA (FT²) <br />HOOD OVER ELECTRIC <br />RANGE <br />HOOD OVER NATURAL GAS <br />RANGE <br />> 1500 50% CE or 110 CFM 70% CE or 180 CFM <br />> 1000 - 1500 50% CE or 110 CFM 80% CE or 250 CFM <br />750 - 1000 50% CE or 130 CFM 85% CE or 280 CFM <br />< 750 50% CE or 160 CFM 85% CE or 280 CFM <br />RH <br />GAS <br />RANGE <br />V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />VASQUEZ <br />RESIDENCE <br />23-017 <br />09-10-2024 <br />S.V <br />714-713-3124 <br />627, 627 UNIT 2 S. SHELTON. ST. <br />SANTA ANA, CA 92703 <br />d e s i g n e r <br />O s c a r V e g a <br />C e 1 4 - 4 -1 2 4 <br />O i e 3 1 - 2 3 -3 5 <br />i n o e o d e s i g n s .o <br />5 3 4 C O A V E . <br />A A E C A 2 5 <br />APPROVED BY :O.V. <br />A-2.4 <br />ELECTRICAL PLAN <br />627 S Shelton St & <br />#212/4/2024