My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
627 S Shelton St Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Shelton St
>
627 S Shelton St Unit# 2
>
627 S Shelton St Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:41:40 PM
Creation date
6/15/2025 12:41:36 PM
Metadata
Fields
Template:
Plan
Permit Number
101120163
Full Address
627 S Shelton St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LI <br />N <br />E <br /> <br />O <br />F <br /> <br />( <br />E <br />) <br /> <br />W <br />A <br />L <br />L <br /> <br />B <br />E <br />L <br />O <br />W <br />IM <br />A <br />G <br />I <br />N <br />A <br />R <br />Y <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br />LI <br />N <br />E <br />8 <br />A-5.1 <br />1'-2" <br />A-4.1 <br />B <br />A <br />A-4.1 <br />A1 <br />A1 <br />A1 <br />A2 <br />A2 <br />(E <br />) <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />0'-6" <br />0' <br />- <br />6 <br />" <br />0'-6" <br />0' <br />- <br />2 <br />" <br />0' <br />- <br />6 <br />" <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />EXISTING ROOF <br />CRICKET <br />2% MIN. SLOPE <br />LI <br />N <br />E <br /> <br />O <br />F <br /> <br />( <br />E <br />) <br />F <br />L <br />O <br />O <br />R <br /> <br />B <br />E <br />L <br />O <br />W <br />LINE OF (E)FLOOR BELOW <br />LI <br />N <br />E <br /> <br />O <br />F <br /> <br />( <br />E <br />) <br />F <br />L <br />O <br />O <br />R <br /> <br />B <br />E <br />L <br />O <br />W <br />LINE OF (E)FLOOR BELOW <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />IM <br />A <br />G <br />I <br />N <br />A <br />R <br />Y <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />4'-1"6'-0" <br />6'-0"3'-4" <br />0'-2" <br />5'-0" <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />S <br />L <br />O <br />P <br />E <br />1'-0" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />5'-0"3'-7" <br />0'-6" <br />2' <br />- <br />5 <br />" <br />4' <br />- <br />0 <br />" <br />ATTIC AREA 1 ATTIC AREA 2 <br />331 Sq.ft173 Sq.ft <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />PROPOSED ROOF PLAN1 <br />SCALE: 1/4" = 1'-0" <br />N <br />5' <br />- <br />0 <br />" <br />3' <br />- <br />4 <br />" <br />2'-0" <br />2'-9" <br />A-5.1 <br />9 <br />A-5.1 <br />9 <br />0' <br />- <br />1 <br />0 <br />" <br />A-5.1 <br />7 <br />NE <br />W <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />NE <br />W <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />0'-2" <br />1' <br />- <br />0 <br />" <br />0'-10" <br />(E) PROPERTY LINE <br />EXISTING DWELLING <br />780 Sq. Ft. <br />(FOR REFERENCE ONLY) <br />A-5.1 <br />7 <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />LINE OF (E)FLOOR BELOW <br />LINE OF (E)FLOOR BELOW <br />0' <br />- <br />2 <br />" <br />(E) ROOF SHINGLES <br />COVERING MATCHING <br />WITH EXISTING HOUSE <br />TO REMAIN <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />NE <br />W <br /> <br />H <br />A <br />L <br />F <br /> <br />R <br />O <br />U <br />N <br />D <br />DO <br />R <br />M <br />E <br />R <br /> <br />V <br />E <br />N <br />T <br />EXISTING GARAGE TO BE CONVERTED INTO AN A.D.U <br />A-5.1 <br />7 <br />10 <br />A-5.1 <br />ATTIC AREA 1 = 173 Sq. Ft.= <br />= HALF ROUND DORMER VENT <br />24" <br />12 <br />" <br />FLAT CEILING AREA 173 Sq. Ft. <br />ATTIC VENT REQUIRED = 173 / 150 = 1.15 Sq. Ft. x 144 = 166 Sq. In. <br />REQUIRED = 166 Sq. In. / PROPOSED = 200 Sq. In.......OK. <br />HATCH LEGEND <br />ATTIC VENTILATION 1 (A1) <br />ATTIC VENTILATION 2 (A2) <br />VENTS OPENINGS SHALL BE PROVIDED WITH CORROSION RESISTANCE <br />WIRE MESH WITH 1/16" MIN. TO 1/4" MAX. OPENINGS. <br />WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT <br />BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A I-INCH (25 MM) SPACE <br />MUST BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF <br />SHEATHING AT THE LOCATION OF THE VENTS. <br />* <br />* <br />ATTIC AREA 331.00 Sq. Ft. <br />ATTIC VENT REQUIRED = 331.00 / 150 = 2.20 Sq. Ft. x 144 = 318 Sq. In. <br />a.- HALF ROUND DORMER VENTS = 100 Sq. In. OF NET FREE AIR FLOW <br />No. OF DORMER VENTS PROVIDED = 4 x 100 Sq. In. = 400 Sq. In. <br />REQUIRED = 318 Sq. In. / PROPOSED = 400 Sq. In.......OK. <br /> = HALF ROUND <br /> DORMER VENT <br />a.- HALF ROUND DORMER VENTS = 100 Sq. In. OF NET FREE AIR FLOW <br />No. OF DORMER VENTS PROVIDED = 2 x 100 Sq. In. = 200 Sq. In. <br />24" <br />12 <br />" <br />ATTIC AREA = 331.00 Sq. Ft.= <br />PORTION OF EXISTING <br />ROOF TO BE REMOVED= <br />=EXISTING ROOF SHINGLES COVERING <br />THIS PORTION OF <br />THE EXISTING <br />ROOF OVERHANG <br />TO BE REMOVED <br />V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />VASQUEZ <br />RESIDENCE <br />23-017 <br />09-24-2024 <br />S.V <br />714-713-3124 <br />627, 627 UNIT 2 S. SHELTON. ST. <br />SANTA ANA, CA 92703 <br />d e s i g n e r <br />O s c a r V e g a <br />C e 1 4 - 4 -1 2 4 <br />O i e 3 1 - 2 3 -3 5 <br />i n o e o d e s i g n s .o <br />5 3 4 C O A V E . <br />A A E C A 2 5 <br />APPROVED BY :O.V. <br />A-2.5 <br />PROPOSED <br />ROOF PLAN <br />627 S Shelton St & <br />#212/4/2024
The URL can be used to link to this page
Your browser does not support the video tag.