My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3110 & 3112 S Griset Pl - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Griset Pl
>
3112 S Griset Pl
>
3110 & 3112 S Griset Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:22 PM
Creation date
6/15/2025 12:43:54 PM
Metadata
Fields
Template:
Plan
Permit Number
101122356
Full Address
3112 S Griset Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
All ideas, drawings,specifications shown herein are the <br />property of West Coast Design Group and shall not be <br />used, copied, reproduced, or disclosed to any person, firm <br />or corporation, without the written consent of West Coast <br />Design Group. Any infringement will be subject to legal <br />action. The contractor shall verify and be responsible for all <br />dimensions and conditions on the job and notify this office of <br />any variations from dimensions and conditions shown <br />herewith. Written dimensions take precedence over scaled <br />dimensions. <br />Mark Transmittal Set Date Description <br />01 <br />02 <br />12/19/2024 <br />3/14/2025 <br />Planning Corr. R1 <br />Building Corr. <br />SHEET TITLE <br />A-3 <br />SHEET 14 <br />PROJECT NO: <br />STATUS: <br />DRAWN BY: <br />CHK'D BY: <br /> <br /> <br />PROJECT: <br />CLIENT: <br />PLOT DATE: 3/14/2025 <br /> 52-24 <br />PLAN CHECK#:101122356 <br /> C <br />: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />j <br />e <br />r <br />r <br />y <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />R <br />e <br />s <br />i <br />d <br />e <br />n <br />t <br />i <br />a <br />l <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />An <br />a <br /> <br />Gr <br />i <br />s <br />e <br />t <br /> <br />PI <br />\ <br />C <br />D <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />G <br />r <br />i <br />s <br />e <br />t <br /> <br />P <br />I <br />. <br />p <br />l <br />n <br /> Submittal <br /> <br />Roof Plan <br />ADU <br />3110 & 3112 S Griset Pl <br />Santa Ana, CA 92704 <br />Matthew Mallari & <br />Natalie Nguyen <br />PLANNING - DESIGN <br />41055 CHACO CANYON ROAD <br />MURRIETA CA 92562 <br />WEST COAST <br />DESIGN GROUP <br />3 <br />A-6 <br />1 <br />A-6 <br />2 <br />A-6 <br />4 <br />A-6 <br />1'-6" <br />1' <br />- <br />6 <br />" <br />1' <br />- <br />6 <br />" <br />1'-6" <br />4:12 <br />SLOPE <br />4:12 <br />SLOPE <br />4:12 <br />SLOPE <br />4:12 <br />SLOPE <br />4:12 <br />SLOPE <br />4:12 <br />SLOPE <br />LINE OF WALLS BELOW <br />CLASS 'A' ASPHALT <br />SHINGLE ROOF OVER <br />(2) LAYERS OF 15# <br />ROOFING FELT OVER <br />SHEATHING. <br />RI <br />D <br />G <br />E <br />TYPICAL UNDERLAYMENT <br />TYP. <br />TYP. <br />PROVIDE (4) EAVE VENTS <br />EVENLY SPACED AROUND ROOF <br />(3) ATTIC VENTS - SEE <br />NOTES THIS SHEET <br />VERIFY OVERHANG TO <br />MATCH WITH MAIN <br />RESIDENCE, TYP. <br />4: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />4: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />02 <br />SCALE: 1/4" = 1'-0"1 Roof Plan <br />1. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN: <br /> a. 1/150 OF THE ATTIC SPACE OR <br /> b. 1/300 PROVIDED A CLASS I OR II VAPOR BARRIER IS INSTALLED <br /> ON THE WARM SIDE OF THE CEILING OR <br /> c. 1/300 PROVIDED THAT AT LEAST 50% AND NOT MORE THAN 80% <br /> OF THE REQUIRED VENTILATION AREA MUST BE LOCATED AT LEAST <br /> 3' ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED <br /> BY EAVE OR CORNICE VENTS. <br />2. EAVE OR CORNICE VENT OPENINGS SHALL NOT BE LOCATED <br />WITHIN 3' LATERALLY ABOVE WINDOWS OR DOORS OF THE STORY <br />BELOW. <br />3. ALL VENTS SHALL HAVE GALVANIZED INSECT SCREENS WITH 8 MESH <br />PER INCH MINIMUM. <br />ATTIC VENTILATION (NET FREE): <br />TOTAL ATTIC VENTILATION REQUIRED = 354 SQ. IN. <br />TOTAL ATTIC VENTILATION PROVIDED = 396 SQ. IN. <br />TOTAL ATTIC SPACE FOR THE ROOF (REQUIRED) =738 SQ FT. X 144 X 1/300 = 354 SQ. IN <br />OF VENTILATION REQUIRED. <br />(4) 6X15 EAVE VENTS (45 NET AREA) = 180 SQ. IN. <br />(3) ROOF VENTS O'HAGIN - (72 NET AREA) = 216 SQ. IN. <br />1. ALL ROOFING MATERIALS, UNDERLAYMENT, FASTNERS AND FLASHING MATERIAL SHALL BE INSTALLED PER <br />MANUFACTURER'S DIRECTION OR PER TRADE STANDARDS; WHICHEVER IS MORE STRINGENT. <br />2. ALL VALLEYS SHALL BE FLASHED. <br />3. ALL JUNCTURES BETWEEN WALLS AND ROOFS SHALL BE FLASHED. IF THE FLASHING IS NOT MADE OF A COPPER MATERIAL, <br />THE FLASHING SHALL BE PRIMED AND PAINTED TO MATCH THE ADJACENT SURFACE. <br />4. ALL ROOF PENETRATIONS SHALL BE PROPERLY FLASHED AND SEALED. THE EXPOSED METAL SHALL BE PRIMED AND <br />PAINTED TO MATCH ROOFING MATERIAL.EFORE PROCEEDING. <br />5. ALL EDGE OF ROOFS SHALL BE FLASHED WITH A METAL FLASHING. METAL FLASHING THAT IS NOT COPPER SHALL BE <br />PRIMED AND PAINTED TO MATCH THE FASCIA. <br />6. ANY CONFLICTS FOUND ON THE PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER OR DESIGNER. <br />7. ALL WORK SHALL CONFORM TO BOTH LOCAL AND STATE CODES. <br />ROOFING MATERIAL INSTALLATION <br />1. THE GENERAL CONTRACTOR SHALL INSTALL THE ASPHALT SHINGLES (CLASS 'A') FOLLOWING ACCEPTED STANDARD <br />PRACTICE. <br />2. THE UNDERLAYMENT SHALL BE TYPE I (15#) ASPHALT SATURATED ROOFING FELT. ONE LAYER SHALL BE INSTALLED OVER A <br />SOLID ROOFING DECK PER ACCEPTED ROOFING STANDARDS. ALL HIPS AND VALLEYS SHALL BE PROPERLY COVERED. <br />3. ORGANIC ASPHALT SHINGLES SHOULD MEET ASTM D225, "STANDARD SPECIFICATION FOR ASPHALT SHINGLES (ORGANIC <br />FELT) SURFACED WITH MINERAL GRANULES." <br />4. FIBERGLASS ASPHALT SHINGLES SHOULD MEET ASTM D3462, "STANDARD SPECIFICATION FOR ASPHALT SHINGLES MADE <br />FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES." <br />5. VALLEY FLASHINGS SHALL BE NOT LESS THAN 0.019-INCH (NO. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT <br />METAL INSTALLED OVER A 36-IN. WIDE UNDERLAYMENT CONSISTING OF ONE LAYER OF 72-POUND MINERAL-SURFACED NON- <br />PERFORATED CAP SHEET MEETING ASTM D3909 RUNNING THE FULL LENGTH OF THE VALLEY. (705A.3 CBC; R337.5.3 CRC) <br />ROOF VENTILATION <br />1. ALL ROOF VENTS SHALL BE INSTALLED PER MANUFACTURERS DIRECTIONS. PAINT TO MATCH ROOFING MATERIAL IF THE <br />COLOR OF THE VENT DOES NOT MATCH. <br />2. SEE THE ROOFING CALCULATION ON THIS PAGE FOR NUMBER OF VENTS. <br />3. SEE ROOFING PLAN FOR LOCATION OF VENTS. <br />4. FLASH ALL VENTS IN ORDER TO PROVIDE A LEAK PROOF CONNECTION. <br />5. EAVE VENTS SHALL BE INSTALLED PER MANUFACTURERS' DIRECTION. PAINT TO MATCH ADJACENT SURFACE.
The URL can be used to link to this page
Your browser does not support the video tag.