Laserfiche WebLink
CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (6) 10 AWG  <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG  <br />THHN/THWN-2 <br />(1) 6 AWG  <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Gateway Output (2) 3 AWG  <br />THHN/THWN-2 <br />(1) 3 AWG  <br />THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT <br />5 Backup Loads <br />(13)  12AWG  <br />THHN/THWN-2 <br />(13)  12AWG  <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />1-1/4 EMT <br />(2)  10AWG  <br />THHN/THWN-2 <br />(1)  10AWG  <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />E EXISTING <br />PAGE <br />REV: D 2/27/2025 <br />ISIDRO MENDOZA <br />2701 S POPLAR ST, SANTA ANA,  <br />CA, 92704 <br />PROJECT NUMBER: <br />  109R-701MEN1 <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 697-7230 <br />APN: 140-273-07 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />#ESTAMP <br />POWER CONTROL SYSTEM (PCS): <br />SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  <br />SUPPLIED BY THE POWER PRODUCTION SOURCES <br />MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. <br />WITH 240.6(C). <br /> SETPOINTS: <br />          - 80A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL <br />          - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) <br />INSTALLER MUST CHECK THE CONDITION,  <br />INSTALLABILITY AND CODE COMPLIANCE OF  <br />EXISTING EQUIPMENT. <br />CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND <br />INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN  <br />TWO SEPARATE CONDUITS <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED  <br />WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 <br />PV-4.1 <br />ELECTRICAL  <br />CONTI <br />GENERAL NOTES: <br />COLD WATER GAS BOND <br />D <br />D <br />2701 S Poplar St <br />3/10/2025