PAGE <br />REV: B1 12/10/2024 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />ISIDRO MENDOZA <br />2701 S POPLAR ST, SANTA ANA,  <br />CA, 92704 <br />PROJECT NUMBER: <br />  109R-701MEN1 <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 697-7230 <br />APN: 140-273-07 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />SYSTEM INFORMATION <br />7.505 KW DC PHOTOVOLTAIC SYSTEM <br />(12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: <br />POWERWALL 3 1707000-XX-Y <br />(7) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: <br />POWERWALL 3 1707000-XX-Y <br />SYSTEM OCPD SIZE <br />(COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  <br />112 A X 1.25 = 140 A → 70 A OVERCURRENT PROTECTION <br />GATEWAY SYSTEM AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = 70 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 95A = 86.45A <br />TERMINAL RATING[110.14(C)] = <br />4 AWG, 75°C RATED = 85A <br />85A < 86.45A   TERMINAL RATING GOVERNS CONDUCTOR SIZING <br />70A < 85A   4 AWG AMPACITY OK <br />THEREFORE 4 AWG IS SUFFICIENT. <br />ALLOWABLE BACKFEED <br />MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = <br />100A <br />70A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS. <br />INVERTER INFORMATION <br />4740 KW DC PHOTOVOLTAIC SYSTEM <br />(12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: <br />POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />14.88A X 1.25 X 1.25 = 23.25A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG, 75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />23.25A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)]  <br />= <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V} X 12 = 472.72 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.88 A X 1 = 18.6A <br />INVERTER INFORMATION <br />2765 KW DC PHOTOVOLTAIC SYSTEM <br />(7) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: <br />POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />14.88A X 1.25 X 1.25 = 23.25A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG, 75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />23.25A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)]  <br />= <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V} X 4 = 157.57 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.88 A X 1 = 18.6A PV-4.2 <br />ELECTRICAL CALCS <br />2701 S Poplar St <br />3/10/2025