Laserfiche WebLink
Highland Manor <br />1128 Highland St <br />Santa Ana, CA, 92703 <br />SHEET NUMBER <br />SH <br />E <br />E <br />T <br /> <br />TI <br />T <br />L <br />E <br />24 <br />2 <br />6 <br />A <br />DAT <br />E <br />JO <br />B <br /> <br />NO. <br />DR <br />A <br />W <br />N <br />PROJECT NAME <br />PROJECT ADDRESS <br />DR <br />A <br />W <br />I <br />N <br />G <br /> <br />LO <br />G <br />DA <br />T <br />E <br />ID <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />12 <br />/ <br />1 <br />2 <br />/ <br />2 <br />4 <br />12 <br />/ <br />2 <br />3 <br />/ <br />2 <br />4 <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />5 <br />01 02 03 <br />PL <br />A <br />N <br />N <br />I <br />N <br />G <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />PR <br />E <br />L <br />I <br />M <br />I <br />N <br />A <br />R <br />Y <br /> <br />B <br />AN <br />D <br /> <br />S <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />B <br />AN <br />D <br /> <br />S <br />CO <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />#1 <br />A040 <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />NO <br />T <br />E <br />S <br />JR <br />, <br /> <br />LF <br />NL <br />ALL IDEAS, DESIGNS, ARRANGEMENTS <br />AND PLANS INDICATED OR REPRESENTED <br />BY THIS DRAWING ARE OWNED BY AND <br />PROPERTY OF BELL DESIGN GROUP AND <br />WERE CREATED, EVOLVED AND <br />DEVELOPED FOR USE ON AND IN <br />CONNECTION WITH THE SPECIFIED <br />PROJECT. NONE OF SUCH IDEAS, <br />DESIGNS, ARRANGEMENTS, OR PLANS <br />SHALL BE USED BY OR DISCLOSED TO <br />ANY PERSON, FIRM OR CORPORATION <br />FOR ANY PURPOSE WHATSOEVER <br />WITHOUT THE WRITTEN PERMISSION OF <br />BELL DESIGN GROUP. WRITTEN <br />DIMENSIONS SHALL TAKE PRECEDENCE <br />OVER SCALED DIMENSIONS. <br />CONTRACTOR SHALL VERIFY AND BE <br />RESPONSIBLE FOR ALL DIMENSIONS AND <br />CONDITIONS ON THE JOB, AND THIS <br />OFFICE MUST BE NOTIFIED OF ANY <br />VARIATIONS FROM DIMENSIONS AND <br />CONDITIONS SHOWN BY THESE <br />DRAWINGS. <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br />: <br /> <br />re <br />l <br />a <br />t <br />i <br />v <br />i <br />t <br />y <br /> <br />- <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br /> <br />So <br />f <br />t <br />w <br />a <br />r <br />e <br /> <br />as <br /> <br />a <br />Se <br />r <br />v <br />i <br />c <br />e <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br /> <br /> <br /> <br />2/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />5: <br />2 <br />4 <br /> <br />PM <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />0 <br />2 <br />5 <br />GENERAL NOTES <br />1. ALL GRADING SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE CALIFORNIA BUILDING <br />CODE. ALL EXCAVATED MATERIAL RESULTING FROM GRADING SHALL BE REMOVED FROM <br />THE SITE BY THE CONTRACTOR. <br />2. ALL CONSTRUCTION AND DETAILS SHALL BE COMPLETED IN FULL COMPLIANCE WITH THE <br />CALIFORNIA UNIFORM BUILDING CODE AND ALL OTHER APPLICABLE CODES AND <br />AMENDMENTS ENACTED BY THE CITY OF LOS ANGELES AND/OR COUNTY OF LOS ANGELES. <br />3. IF ANY CONFLICT IN INFORMATION IS DISCOVERED WITH REFERENCES TO STANDARDS OF <br />PERFORMANCE OR CONSTRUCTION OR WORKMANSHIP, THE MORE ONEROUS PROVISION <br />SHALL BE DEEMED TO APPLY UNLESS OTHERWISE AGREED TO BY THE ARCHITECT. <br />4. THE CONTRACTOR (AND HIS SUB-CONTRACTORS) SHALL STUDY AND COMPARE THE <br />CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO THE ARCHITECT IN WRITING, ALL <br />INCONSISTENCIES, ERRORS OR OMISSIONS DISCOVERED AND VERIFY ALL DIMENSIONS ON <br />SITE PRIOR TO COMMENCING THE WORK. IF THE CONTRACTOR PROCEEDS WITH ANY OF <br />THE WORK SO AFFECTED WITHOUT WRITTEN INSTRUCTIONS OF THE ARCHITECT, THE <br />CONTRACTOR SHALL MAKE GOOD AT HIS OWN COST ANY RESULTING ERROR,DAMAGE, OR <br />DEFECTS OR TIME DELAYS SO CAUSED. THE CONTRACTOR SHALL PERFORM NO PORTION <br />OF THE WORK WITHOUT CONTRACT DOCUMENTS OR, WHERE REQUIRED, APPROVED SHOP <br />DRAWINGS,PRODUCT DATA OR SAMPLES BEING AVAILABLE ON SITE FOR WORKERS TO <br />REFER TO, FOR SUCH PORTION OF THE WORK. <br />5. CONTRACTOR SHALL PROVIDE A BLANKET ONE-YEAR GUARANTEE FOR THE TOTAL JOB <br />WITH THE SEPARATE GUARANTEE FOR SPECIFIC TRADES/EQUIPMENT ITEMS, WITH THE <br />NAMES OF LOCAL REPRESENTATIVES TO BE CONTRACTED FOR SERVICE. THE <br />CONTRACTOR SHALL PROVIDE OPERATING AND MAINTENANCE BROCHURES AS REQUIRED. <br />THE GUARANTEE SHALL COMMENCE WHEN THE WORK IS DEEMED SUBSTANTIALLY <br />COMPLETE BY THE ARCHITECT. <br />6. CONTRACTOR SHALL PROVIDE ONE MARKED UP SET OF DRAWINGS INDICATING ALL <br />DIFFERENCES,CHANGES, ETC., AND ACTUAL LOCATIONS OF CONCEALED WORK, BEFORE <br />ARCHITECT'S FINAL INSPECTION. <br />7. WHERE SPECIFIED ITEMS ARE MENTIONED, THE CONTRACTOR MAY SUBMIT ALTERNATE <br />MATERIALS FOR APPROVAL BY THE OWNER AND THE ARCHITECT. SUBMISSION PACKAGE <br />SHALL CONTAIN BROCHURE, CUT SHEETS, SPECIFICATIONS, COSTS, AVAILABILITY, <br />REFERENCES, ETC. CONTRACTOR SHALL REIMBURSE ARCHITECT FOR TIME SPENT <br />EVALUATING ALTERNATIVES OR SUBSTITUTIONS THAT ARE SUBMITTED AFTER PROJECT <br />CONSTRUCTION HAS COMMENCED. <br />8. DO NOT SCALE DRAWINGS. <br />9. CONTRACTOR SHALL CONSULT WITH REPRESENTATIVES OF APPLICABLE UTILITIES, <br />INCLUDING BUT NOT LIMITED TO GAS, WATER, POWER, SEWER, TELEPHONE, AND CABLE <br />TELEVISION AND DETERMINE EXACT LOCATIONS AND AVAILABILITY OF UTILITIES AND <br />DETERMINE CONDITION OF EXISTING SERVICE PRIOR TO COMMENCING WORK OR <br />CONNECTING UTILITIES. CONTRACTOR SHALL LOCATE UTILITIES BY POTHOLING PRIOR TO <br />BEGINNING CONSTRUCTION. <br />10. CONTRACTOR TO STAKE OUT ALL WORKS AS SHOWN ON PLANS, CONFIRM EXISTING <br />CONDITIONS AND PROPERTY LINE LOCATIONS, AND VERIFY COMPLIANCE WITH SETBACKS <br />AND CLEARANCES REQUIRED BY CODE. <br />11. IMPROVEMENTS ON THE SITE, WORK IN PROGRESS, STORED MATERIALS, AND PUBLIC AND <br />PRIVATE IMPROVEMENTS ON PROPERTY ADJACENT TO THE SITE SHALL BE PROTECTED BY <br />THE CONTRACTOR FROM DAMAGE ARISING FROM THE WORK. ALL DAMAGE SO OCCURRING <br />SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO OWNER. <br />12. STRUCTURAL OBSERVATION BY THE STRUCTURAL ENGINEER ARE REQUIRED BY THE LOCAL <br />JURISDICTION. A WRITTEN STATEMENT SHALL BE GIVEN TO THE BUILDING OFFICIAL, <br />STATING THAT SITE VISITS HAVE BEEN MADE AND WHETHER OR NOT ANY OBSERVED <br />DEFICIENCIES HAVE BEEN CORRECTED TO CONFORM TO THE APPROVED PLANS AND <br />SPECIFICATIONS. <br />13. INSPECTION OF NAILING REQUIRED FOR DRYWALL AND ALL LATH WHEN IN PLACE. CORNER <br />BEADS ARE TO BE NAILED. FASTENERS USED FOR THE ATTACHMENT OF GYPSUM BOARD TO <br />A HORIZONTAL DIAPHRAGM CEILING SHALL BE AS DEFINED IN TABLE 2508.5, FASTENERS <br />SHALL NOT BE MORE THAN 7" O.C, AT ALL SUPPORTS, INCLUDING PERIMETER BLOCKING, <br />AND NOT MORE THAN 3/8 INCH FROM EDGES AND ENDS OF THE GYPSUM. BOARD [CBC <br />2508.5.4] <br />14. CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C <br />1178, C 1288 OR C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER <br />RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS <br />AND WALL AND CEILING PANELS IN SHOWER AREAS. [CBC 2509.2]. <br />SECURITY NOTES (CONT'D) <br />13. THE FOLLOWING REQUIREMENTS MUST BE MET FOR WINDOWS AND SLIDING GLASS <br />DOORS: (1) EXCEPT AS OTHERWISE SPECIFIED IN MUNICIPAL CODE SECTIONS 8.48.1 <br />(SPECIAL RESIDENTIAL BUILDING PROVISIONS) AND 8.48.130 (SPECIAL COMMERCIAL <br />BUILDING PROVISIONS), ALL OPERABLE EXTERIOR WINDOWS AND SLIDING GLASS <br />DOORS SHALL COMPLY WITH THE TESTS AS SET FORTH IN SECTION 8.48.140 (TESTS). (2) <br />WINDOW ASSEMBLIES WHICH ARE DESIGNED TO BE OPERABLE AND WHICH ARE <br />REGULATED BY THIS CHAPTER SHALL COMPLY WITH UNIFORM BUILDING CODE <br />STANDARD 10-6, UNLESS SUCH WINDOWS ARE PROTECTED BY APPROVED METAL BARS, <br />SCREENS OR GRILLES. (3) SLIDING DOOR ASSEMBLIES REGULATED BY THIS CHAPTER <br />SHALL COMPLY WITH UNIFORM BUILDING CODE STANDARD 10-5, PART II. (4) LOUVERED <br />WINDOWS SHALL NOT BE USED WHEN ANY PORTION OF THE WINDOW IS LESS THAN <br />TWELVE FEET VERTICALLY OR SIX FEET HORIZONTALLY FROM AN ACCESSIBLE SURFACE <br />OR ANY ADJOINING ROOF, BALCONY, LANDING, STAIR TREAD, PLATFORM, OR SIMILAR <br />STRUCTURE UNLESS SUCH WINDOWS ARE PROTECTED BY APPROVED METAL BARS, <br />SCREENS, OR GRILLS. (ADDED BY ORD. NO. 1945CCS § 12 (PART), ADOPTED 6/8/99) <br />14. GARAGE TYPE DOORS - ROLLING OVERHEAD, SOLID OVERHEAD, SWING, ADDED BY <br />SLIDING OR ACCORDION SHALL CONFORM TO THE FOLLOWING STANDARDS: (1) <br />ALUMINUM DOORS SHALL BE A MINIMUM THICKNESS OF .0215 INCHES AND RIVETED <br />TOGETHER A MINIMUM OF EIGHTEEN INCHES ON CENTER ALONG THE OUTSIDE SEAMS. <br />THERE SHALL BE A FULL WIDTH HORIZONTAL BEAM ATTACHED TO THE MAIN DOOR <br />STRUCTURE WHICH SHALL MEET THE PILOT, OR PEDESTRIAN ACCESS, DOOR FRAMING <br />WITHIN THREE INCHES OF THE STRIKE AREA OF THE PILOT OR PEDESTRIAN ACCESS <br />DOOR. (3) DOORS THAT EXCEED SIXTEEN FEET IN WIDTH SHALL HAVE TWO LOCK <br />RECEIVING POINTS; OR, IF THE DOOR DOES NOT EXCEED NINETEEN FEET, A SINGLE <br />BOLT MAY BE USED IF PLACED IN THE CENTER OF THE DOOR WITH THE LOCKING POINT <br />LOCATED EITHER AT THE FLOOR OR DOOR FRAME HEADER; OR, TORSION SPRING <br />COUNTER BALANCE TYPE HARDWARE MAY BE USED. (4) EXCEPT IN A RESIDENTIAL <br />BUILDING, DOORS SECURED BY ELECTRICAL OPERATION SHALL HAVE A KEYED SWITCH <br />TO OPEN THE DOOR WHEN IN A CLOSED POSITION, OR BY A SIGNAL LOCKING DEVICE. (5) <br />DOORS WITH SLIDE BOLT ASSEMBLIES SHALL HAVE FRAMES A MINIMUM OF .120 INCHES <br />IN THICKNESS, WITH A MINIMUM BOLT DIAMETER OF ONE-HALF INCH AND PROTRUDE AT <br />LEAST ONE AND ONE-HALF INCHES INTO THE RECEIVING GUIDE. A BOLT DIAMETER OF <br />THREE-EIGHTHS OF AN INCH MAY BE USED IN A RESIDENTIAL BUILDING. THE SLIDE BOLT <br />SHALL BE ATTACHED TO THE DOOR WITH NON-REMOVABLE BOLTS FROM THE OUTSIDE. <br />RIVETS SHALL NOT BE USED TO ATTACH SLIDE BOLT ASSEMBLIES. (6) EXCEPT IN A <br />RESIDENTIAL BUILDING, PADLOCK(S) USED WITH EXTERIOR MOUNTED SLIDE BOLT (S) <br />SHALL HAVE A HARDENED STEEL SHACKLE LOCKING BOTH AT HEEL AND TOE AND A <br />MINIMUM FIVE-PIN TUMBLER OPERATION WITH NON-REMOVABLE KEY WHEN IN AN <br />UNLOCKED POSITION. PADLOCK(S) USED WITH INTERIOR MOUNTED SLIDE BOLT SHALL <br />HAVE A HARDENED STEEL SHACKLE WITH A MINIMUM FOUR PIN TUMBLER OPERATION. <br />(ADDED BY ORD. NO. 1945CCS § 12 (PART), ADOPTED 6/8/99) <br />15. SWINGING EXTERIOR GLASS DOORS, WOOD OR METAL DOORS WITH GLASS PANELS, <br />SOLID WOOD OR METAL DOORS SHALL BE CONSTRUCTED OR PROTECTED AS FOLLOWS: <br />(1) WOOD DOORS SHALL BE OF SOLID CORE CONSTRUCTION WITH A MINIMUM <br />THICKNESS OF ONE AND THREE-FOURTHS (1- 3/4) INCHES. WOOD PANEL DOORS WITH <br />PANELS LESS THAN ONE (1) INCH THICK SHALL BE COVERED ON THE INSIDE WITH A <br />MINIMUM SIXTEEN (16) U.S. GAUGE SHEET STEEL, OR ITS EQUIVALENT, WHICH IS TO BE <br />ATTACHED WITH SCREWS ON MINIMUM SIX (6) INCH CENTERS. HOLLOW STEEL DOORS <br />SHALL BE OF A MINIMUM SIXTEEN (16) U.S. GAUGE AND HAVE SUFFICIENT <br />REINFORCEMENT TO MAINTAIN THE DESIGNED THICKNESS OF THE DOOR WHEN ANY <br />LOCKING DEVICE IS INSTALLED; SUCH REINFORCEMENT BEING ABLE TO RESTRICT <br />COLLAPSING OF THE DOOR AROUND ANY LOCKING DEVICE. (2) ANY GLAZING UTILIZED <br />WITHIN 40 INCHES OF ANY DOOR LOCKING MECHANISM SHALL BE CONSTRUCTED OR <br />PROTECTED AS FOLLOWS: (A) FULLY TEMPERED GLASS OR RATED BURGLARY <br />RESISTANT GLAZING; OR (B) IRON OR STEEL GRILLS OF AT LEAST ONE-EIGHTH (1/8) INCH <br />MATERIAL WITH A MINIMUM TWO (2) INCH MESH SECURED ON THE INSIDE OF THE <br />GLAZING MAY BE UTILIZED; OR (C) THE GLAZING SHALL BE COVERED WITH IRON BARS <br />OF AT LEAST ONE-HALF (2) INCH ROUND OR ONE INCH BY ONE-FOURTH INCH (1" X 1/4") <br />FLAT STEEL MATERIAL, SPACED NOT MORE THAN FIVE (5) INCHES APART, SECURED ON <br />THE INSIDE OF THE GLAZING. (D) ITEMS (B) AND (C) ABOVE SHALL NOT INTERFERE WITH <br />THE OPERATION OF OPENING WINDOWS IF SUCH WINDOWS ARE REQUIRED TO BE <br />OPERABLE BY THE CALIFORNIA BUILDING CODE. <br />16. ALL SWINGING EXTERIOR WOOD AND STEEL DOORS SHALL BE EQUIPPED AS FOLLOWS: <br />(1) A SINGLE OR DOUBLE DOOR SHALL BE EQUIPPED WITH A SINGLE CYLINDER <br />DEADBOLT LOCK. THE DEADBOLT LOCK MUST BE ACTUATED BY A KEY FROM THE <br />EXTERIOR AND A KNOB OR THUMB TURN FROM THE INTERIOR AND WHEN PROJECTED <br />BECOMES LOCKED AGAINST RETURN BY END PRESSURE. THE BOLT SHALL HAVE A <br />MINIMUM PROJECTION OF ONE (1) INCH AND BE CONSTRUCTED SO AS TO REPEL <br />CUTTING TOOL ATTACK. THE DEADBOLT SHALL HAVE AN EMBEDMENT OF AT LEAST <br />THREE-FOURTHS (3/4) INCH INTO THE STRIKE RECEIVING THE PROJECTED BOLT. THE <br />CYLINDER SHALL HAVE A CYLINDER GUARD, A MINIMUM OF FIVE PIN TUMBLERS, AND <br />SHALL BE CONNECTED TO THE INNER PORTION OF THE LOCK BY CONNECTING SCREWS <br />OF AT LEAST ONE-FOURTH INCH IN DIAMETER. THE PROVISIONS OF THE PRECEDING <br />PARAGRAPH DO NOT APPLY WHERE (1) PANIC HARDWARE IS REQUIRED, OR (2) AN <br />EQUIVALENT DEVICE IS APPROVED BY THE ENFORCING AUTHORITY. (2) DOUBLE DOORS <br />SHALL BE EQUIPPED AS FOLLOWS: (A) THE INACTIVE LEAF OF DOUBLE DOOR(S) SHALL <br />BE EQUIPPED WITH METAL FLUSH BOLTS HAVING A MINIMUM EMBEDMENT OF FIVE- <br />EIGHTHS INCH INTO THE HEAD AND THRESHOLD OF THE DOOR FRAME. (B) DOUBLE <br />DOORS SHALL HAVE AN ASTRAGAL CONSTRUCTED OF STEEL A MINIMUM OF .125 INCH <br />THICK WHICH WILL COVER THE OPENING BETWEEN THE DOORS. THE ASTRAGAL SHALL <br />BE A MINIMUM OF TWO INCHES WIDE, AND EXTEND A MINIMUM OF ONE INCH BEYOND <br />THE EDGE OF THE DOOR TO WHICH IT IS ATTACHED. THE ASTRAGAL SHALL BE ATTACHED <br />TO THE OUTSIDE OF THE ACTIVE DOOR BY MEANS OF WELDING OR WITH <br />NONREMOVABLE BOLTS SPACED APART ON NOT MORE THAN TEN-INCH CENTERS. <br />ALUMINUM FRAME SWINGING DOORS SHALL BE EQUIPPED AS FOLLOWS: (1) THE JAMB <br />ON ALL ALUMINUM FRAME SWINGING DOORS SHALL BE SO CONSTRUCTED OR <br />PROTECTED TO WITHSTAND SIXTEEN HUNDRED POUNDS OF PRESSURE IN BOTH A <br />VERTICAL DISTANCE OF THREE INCHES AND A HORIZONTAL DISTANCE OF ONE INCH <br />EACH SIDE OF THE STRIKE, SO AS TO PREVENT VIOLATION OF THE STRIKE. (2) A SINGLE <br />OR DOUBLE DOOR SHALL BE EQUIPPED WITH A DOUBLE CYLINDER DEADBOLT WITH A <br />BOLT PROJECTION EXCEEDING ONE INCH, OR A HOOK SHAPED OR EXPANDING DOG <br />BOLT THAT ENGAGES THE STRIKE SUFFICIENTLY TO PREVENT SPREADING. THE <br />DEADBOLT LOCK SHALL HAVE A MINIMUM OF FIVE PIN TUMBLERS AND A CYLINDER <br />GUARD. <br />17. ALUMINUM FRAME SWINGING DOORS SHALL BE EQUIPPED AS FOLLOWS: (1) THE JAMB <br />ON ALL ALUMINUM FRAME SWINGING DOORS SHALL BE SO CONSTRUCTED OR <br />PROTECTED TO WITHSTAND SIXTEEN HUNDRED POUNDS OF PRESSURE IN BOTH A <br />VERTICAL DISTANCE OF THREE INCHES AND A HORIZONTAL DISTANCE OF ONE INCH <br />EACH SIDE OF THE STRIKE, SO AS TO PREVENT VIOLATION OF THE STRIKE. (2) A SINGLE <br />OR DOUBLE DOOR SHALL BE EQUIPPED WITH A DOUBLE CYLINDER DEADBOLT WITH A <br />BOLT PROJECTION EXCEEDING ONE INCH, OR A HOOK SHAPED OR EXPANDING DOG <br />BOLT THAT ENGAGES THE STRIKE SUFFICIENTLY TO PREVENT SPREADING. THE <br />DEADBOLT LOCK SHALL HAVE A MINIMUM OF FIVE PIN TUMBLERS AND A CYLINDER <br />GUARD. <br />18. PANIC HARDWARE, WHENEVER REQUIRED BY THE CALIFORNIA BUILDING CODE OR TITLE <br />19 OF THE CALIFORNIA ADMINISTRATIVE CODE, SHALL BE INSTALLED AS FOLLOWS: (1) <br />PANIC HARDWARE SHALL CONTAIN A MINIMUM OF TWO LOCKING POINTS ON EACH <br />DOOR; OR (2) ON SINGLE DOORS, PANIC HARDWARE MAY HAVE ONE LOCKING POINT <br />WHICH IS NOT TO BE LOCATED AT EITHER THE TOP OR BOTTOM RAILS OF THE DOOR <br />FRAME. THE DOOR SHALL HAVE AN ASTRAGAL CONSTRUCTED OF STEEL 0.125 INCH <br />THICK WHICH SHALL BE ATTACHED WITH NON-REMOVABLE BOLTS TO THE OUTSIDE OF <br />THE DOOR. THE ASTRAGAL SHALL EXTEND A MINIMUM OF SIX INCHES VERTICALLY <br />ABOVE AND BELOW THE LATCH OF THE PANIC HARDWARE. THE ASTRAGAL SHALL BE A <br />MINIMUM OF TWO INCHES WIDE AND EXTEND A MINIMUM OF ONE INCH BEYOND THE <br />EDGE OF THE DOOR TO WHICH IT IS ATTACHED. (3) DOUBLE DOORS CONTAINING PANIC <br />HARDWARE SHALL HAVE AN ASTRAGAL ATTACHED TO THE DOORS AT THEIR MEETING <br />POINT WHICH WILL CLOSE THE OPENING BETWEEN THEM, BUT NOT INTERFERE WITH <br />THE OPERATION OF EITHER DOOR. <br />19. HORIZONTAL SLIDING DOORS SHALL BE EQUIPPED WITH A METAL GUIDE TRACK AT TOP <br />AND BOTTOM AND A CYLINDER LOCK AND/OR PADLOCK WITH A HARDENED STEEL <br />SHACKLE WHICH LOCKS AT BOTH HEEL AND TOE, AND A MINIMUM FIVE PIN TUMBLER <br />OPERATION WITH NON-REMOVABLE KEY WHEN IN AN UNLOCKED POSITION. THE BOTTOM <br />TRACK SHALL BE SO DESIGNED THAT THE DOOR CANNOT BE LIFTED FROM THE TRACK <br />WHEN THE DOOR IS IN A LOCKED POSITION. <br />20. IN OFFICE BUILDINGS (MULTIPLE OCCUPANCY), ALL ENTRANCE DOORS TO INDIVIDUAL <br />OFFICE SUITES SHALL MEET THE CONSTRUCTION AND LOCKING REQUIREMENTS FOR <br />EXTERIOR DOORS. <br />21. WINDOWS SHALL BE DEEMED ACCESSIBLE IF LESS THAN TWELVE FEET ABOVE GROUND. <br />ACCESSIBLE WINDOWS HAVING A PANE EXCEEDING NINETY-SIX SQUARE INCHES IN AN <br />AREA WITH THE SMALLEST DIMENSION EXCEEDING SIX INCHES AND NOT VISIBLE FROM A <br />PUBLIC OR PRIVATE THOROUGHFARE SHALL BE PROTECTED IN THE FOLLOWING <br />MANNER: (1) FULLY TEMPERED GLASS OR BURGLARY-RESISTANT GLAZING; OR (2) THE <br />FOLLOWING WINDOWS BARRIERS MAY BE USED BUT SHALL BE SECURED WITH NON- <br />REMOVABLE BOLTS: (A) INSIDE OR OUTSIDE IRON BARS OF AT LEAST ONE-HALF-INCH <br />ROUNDED ONE BY ONE-QUARTER INCH FLAT STEEL MATERIAL, SPACED NOT MORE THAN <br />FIVE INCHES APART AND SECURELY FASTENED; OR (B) INSIDE OR OUTSIDE IRON OR <br />STEEL GRILLS OF AT LEAST ONE-EIGHTH-INCH MATERIAL WITH NOT MORE THAN A TWO- <br />INCH MESH AND SECURELY FASTENED. (3) F A SIDE OR REAR WINDOW IS OF THE TYPE <br />THAT CAN BE OPENED, IT SHALL, WHERE APPLICABLE, (4) THE PROTECTIVE BARS OR <br />GRILLS SHALL NOT INTERFERE WITH THE <br />OPERATION OF OPENING <br />22. ALL EXTERIOR TRANSOMS EXCEEDING NINETY-SIX SQUARE INCHES ON THE SIDE AND <br />REAR OF BE SECURED ON THE INSIDE WITH EITHER A SLIDE BAR, BOLT, CROSSBAR, <br />AUXILIARY LOCKING DEVICE, ANY BUILDING OR PREMISES USED FOR BUSINESS <br />PURPOSES SHALL BE PROTECTED BY ONE OF THE FOLLOWING: AND/OR PADLOCK WITH <br />HARDENED STEEL SHACKLE, A MINIMUM FOUR PIN TUMBLER OPERATION. <br />(1) FULLY TEMPERED GLASS OR RATED BURGLARY-RESISTANT GLAZING; OR WINDOWS IF <br />SUCH WINDOWS ARE REQUIRED TO BE OPERABLE BY THE CALIFORNIA BUILDING CODE. <br />(2) THE FOLLOWING BARRIERS MAY BE USED BUT SHALL BE SECURED WITH NON- <br />REMOVABLE BOLTS: (A) OUTSIDE IRON BARS OF AT LEAST ONE-HALF-INCH ROUND OR <br />ONE BY ONE-QUARTER-INCH FLAT STEEL MATERIAL, SPACED NO MORE THAN FIVE <br />INCHES APART AND SECURELY FASTENED; OR (B) OUTSIDE IRON OR STEEL GRILLS OF AT <br />LEAST ONE-EIGHTH-INCH WITH NOT MORE THAN A TWO INCH MESH AND SECURELY <br />FASTENED <br />(3) THE PROTECTIVE BARS OR GRILLS SHALL NOT INTERFERE WITH THE OPERATION OF <br />OPENING THE TRANSOMS IF SUCH TRANSOMS ARE REQUIRED TO BE OPERABLE BY THE <br />CALIFORNIA BUILDING CODE OR TITLE 19, CALIFORNIA ADMINISTRATIVE CODE. <br />SECURITY NOTES (CONT'D) <br />23. ROOF OPENINGS SHALL BE EQUIPPED AS FOLLOWS: (1) ALL SKYLIGHTS ON THE ROOF OF <br />ANY BUILDING OR PREMISES USED FOR BUSINESS PURPOSES SHALL BE PROVIDED WITH: <br />(A) RATED BURGLARY-RESISTANT GLAZING; OR (B) IRON BARS OF AT LEAST ONE-HALF-INCH <br />ROUND OR ONE BY ONE-FOURTH-INCH FLAT STEEL MATERIAL UNDER THE SKYLIGHT AND <br />SECURELY FASTENED; OR (C) A STEEL GRILL OR AT LEAST ONE-EIGHTH-INCH MATERIAL <br />WITH A MAXIMUM TWO-INCH MESH UNDER THE SKYLIGHT AND SECURELY FASTENED. (2) ALL <br />HATCHWAY OPENINGS ON THE ROOF OF ANY BUILDING OR PREMISES USED FOR BUSINESS <br />PURPOSES SHALL BE SECURED AS FOLLOWS: (A) IF THE HATCHWAY IS OF WOODEN <br />MATERIAL, IT SHALL BE COVERED ON THE INSIDE WITH AT LEAST SIXTEEN U.S. GAUGE <br />SHEET METAL, OR ITS EQUIVALENT, ATTACHED WITH SCREWS. (B) THE HATCHWAY SHALL BE <br />SECURED FROM THE INSIDE WITH A SLIDE BAR OR SLIDE BOLTS. (C) OUTSIDE HINGES ON <br />ALL HATCHWAY OPENINGS SHALL BE PROVIDEWDITH NON-REMOVABLE PINS WHEN USING <br />PIN-TYPE HINGES. (3) ALL AIR DUCT OR AIR VENT OPENINGS EXCEEDING NINETY-SIX <br />SQUARE INCHES ON THE ROOF OR EXTERIOR WALLS OF ANY BUILDING OR PREMISES USED <br />FOR BUSINESS PURPOSES SHALL BE SECURED BY COVERING THE SAME WITH EITHER OF <br />THE FOLLOWING: (A) BARS OF AT LEAST ONE-HALF-INCH ROUND OR ONE BY ONE-FOURTH <br />INCH FLAT STEEL MATERIAL SPACED NO MORE THAN FIVE INCHES APART AND SECURELY <br />FASTENED; OR (B) IRON OR STEEL GRILLS OF AT LEAST ONE-EIGHTH-INCH MATERIAL WITH A <br />MAXIMUM TWO-INCH MESH AND SECURELY FASTENED. (C) IF THE BARRIER IS ON THE <br />OUTSIDE, IT SHALL BE SECURED WITH BOLTS WHICH ARE NONREMOVABLE FROM THE <br />EXTERIOR. (D) THE ABOVE (A AND B) MUST NOT INTERFERE WITH VENTING REQUIREMENTS <br />CREATING A POTENTIALLY HAZARDOUS CONDITION TO HEALTH AND SAFETY OR CONFLICT <br />WITH THE PROVISIONS OF THE CALIFORNIA BUILDING CODE OR TITLE 19 OF THE <br />CALIFORNIA ADMINISTRATIVE CODE. <br />24. PERMANENTLY AFFIXED LADDERS LEADING TO ROOFS SHALL BE FULLY ENCLOSED WITH <br />SHEET METAL TO A HEIGHT OF TEN FEET. THIS COVERING SHALL BE LOCKED AGAINST THE <br />LADDER WITH A CASE HARDENED HASP, SECURED WITH NON-REMOVABLE SCREWS OR <br />BOLTS. HINGES ON THE COVER WILL BE PROVIDED WITH NON-REMOVABLE PINS WHEN <br />USING PIN-TYPE HINGES. IF A PADLOCK IS USED, IT SHALL HAVE A HARDENED STEEL <br />SHACKLE, LOCKING AT BOTH HEEL AND TOE, AND A MINIMUM FIVE PIN TUMBLER OPERATION <br />WITH NONREMOVABLE KEY WHEN IN AN UNLOCKED POSITION. <br />25. A BUILDING LOCATED WITHIN EIGHT FEET OF UTILITY POLES OR SIMILAR STRUCTURES <br />WHICH CAN BE USED TO GAIN ACCESS TO THE BUILDING'S ROOF, WINDOWS OR OTHER <br />OPENINGS SHALL <br />GLAZING NOTES <br />1. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE <br />IDENTIFIED HAVE SUCH ACCESS AREA BARRICADED OR FENCED WITH MATERIALS TO <br />DETER HUMAN CLIMBING. BY A MANUFACTURER'S DESIGNATION SPECIFYING WHO APPLIED <br />THE DESIGNATION, THE MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING <br />STANDARD. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS <br />FOR THE PURPOSED OF SAFETY GLAZING. GLAZING IN SECTION 2406. <br />A. SWING DOORS. <br />B. FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND <br />BIFOLD CLOSET DOOR ASSEMBLIES. <br />C. STORM DOORS. <br />D. UNFRAMED SWINGING DOORS. <br />E. DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS, AND SHOWERS <br />F. FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED <br />EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A <br />CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE WALKING SURFACE. <br />G. FIXED OR OPERABLE PANELS OTHER THAN DESCRIBED IN ITEMS E AND F, WHICH MEETS <br />ALL OF THE FOLLOWING CONDITIONS: <br />i. EXPOSED AREA OF THE INDIVIDUAL PANE GREATER THEN 9 S.F <br />ii. EXPOSED BOTTOM EDGE LESS THEN 18" ABOVE THE FLOOR. iii. EXPOSED TOP EDGE <br />GREATER THEN 36" ABOVE THE FLOOR <br />iv. ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE PLANE OF THE <br />GLAZING <br />H. GUARDS AND RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE. <br />INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS. <br />I. WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS AND SPAS <br />WHERE ALL OF THE FOLLOWING CONDITIONS ARE PRESENT: <br />i. THE BOTTOM EDGE OF THE GLAZING IS LESS THEN 60" ABOVE A WALKING SURFACE ON <br />THE POOL OR SPA SIDE OF THE GLAZING. <br />ii. THE GLAZING IS WITHIN 60" OF A SWIMMING POOL OR SPA WATER'S EDGE. <br />J. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A <br />WALKING <br />SURFACE, WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THEN 60" ABOVE THE <br />PLANE OF THE ADJACENT WALKING SURFACE. <br />K. ADJACENT TO STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A <br />STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE PLANE IS LESS THEN <br />60" ABOVE THE NOSE OF THE TREAD. <br />2. ALL GLASS DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED TO SHOW <br />COMPLIANCE WITH AIR INFILTRATION STANDARDS OF THE 1972 ANSI A134.1, A134.2, A134.3, <br />AND A134.4. <br />REFLECTED CEILING NOTES <br />1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20% OF <br />THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE <br />A MINIMUM CEILING WEIGHT OF FIVE POUNDS PER SQUARE FOOT TO DETERMINE THE <br />LATERAL FORCE. <br />2. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE <br />PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING <br />METHODS MAY BE EMPLOYED: <br />2.1 PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM NO. 12-GAUGE SPLAYED IN <br />FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2” <br />OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 <br />DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS <br />12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4 FEET FROM <br />EACH WALL. <br />2.2. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS <br />RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE <br />RUNNERS AT THE OTHER TWO WALLS. <br />2.3. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. IN ADDITION, <br />VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8” OF DISCONTINUITIES SUCH AS MAY <br />OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. <br />2.4. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE <br />STRUCTURE ABOVE. <br />3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER <br />HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL <br />UNITS, UNLESS OTHERWISE NOTED. <br />4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT <br />FINISH, UNLESS OTHERWISE NOTED. <br />FINISH NOTES <br />1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, AND FREE OF <br />IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS <br />HAVE BEEN CORRECTED. <br />2. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW <br />FINISHES. <br />3. PROVIDE STRAIGHT, FLUSH RESILIENT BASE AT CARPETED AREAS, AND COVED, TOP SET <br />RESILIENT BASE AT RESILIENT FLOORING, UNLESS OTHERWISE NOTED. <br />MEANS OF EGRESS <br />1. THE MEANS OF EGRESS SHALL BE ILLUMINATED WITH AT LEAST 1 FOOT CANDLE AT THE <br />FLOOR LEVEL, IN ADDITION TO ANY OTHER CODE REQUIREMENTS. <br />2. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />3. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT <br />LESS THAN 5 FOOT CANDLES (54 LUX). <br />4. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED <br />IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SECTION 2702. <br />5. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. <br />6. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL <br />PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY POWER LOSS. <br />(1011.2-1011.5.3) <br />7. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE <br />OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SEE 1008.1.8.3 <br />8. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34" <br />AND A MAX 48" ABOVE FINISHED FLOOR. <br />9. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. <br />10. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1008.1.8-1008.1.8.6. <br />11. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL <br />TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS <br />OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE <br />WALKING SURFACE. (1006.1) <br />12. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE <br />PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY <br />FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE <br />FOLLOWING AREAS: <br />A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE <br />TWO OR MORE MEANS OF EGRESS: <br />B. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO <br />HAVE TWO OR MORE EXITS. <br />C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE <br />UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR <br />MORE EXITS. <br />D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1024.1, IN <br />BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br />E. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.5, FOR EXIT DISCHARGE <br />DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br />MEANS OF EGRESS (CONT'D) <br />13. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT <br />LESS THAN 30 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT <br />OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM <br />SHALL BE IN ACCORDANCE WITH SECTION 2702. (1006.3) <br />14. EXIT SIGN(S) ARE REQUIRED WHEN 2 OR MORE EXITS ARE REQUIRED. SHOW LOCATION <br />OF ALL EXIT SIGNS (CBC 1011.1) EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED <br />TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 <br />LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG THE <br />PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO <br />DECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.006 <br />FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION, A <br />MAXIMUM-TOMINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE <br />EXCEEDED. <br />15. THE EXIT SIGN SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM <br />PROVIDED FROM STORAGE BATTERIES UNIT EQUIPMENT OR AN ON-SITE GENERATOR <br />SET, AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL <br />CODE. SHOW TWO SOURCES OF POWER FOR MEANS OF EGRESS. (CBC 1006.3) <br />16. EXIT SIGN ARE REQUIRED FOR FLOOR-LEVEL EXIT SIGNS AND EXIT PATH MARKINGS PER <br />CBC 1011.7 AND 1011.8. <br />POWER AND COMMUNICATION NOTES <br />1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE <br />LOCATIONS WITHOWNER. <br />2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS. <br />3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH <br />MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. <br />4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT. <br />5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. <br />6. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH TITLE 24 REQUIREMENTS. FOR ROOMS <br />OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH <br />SWITCH CONTROLLING 50%OF LAMPS PER FIXTURE. <br />7. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED <br />BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND <br />LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER <br />LINE AT +3'-2" ABOVE FINISHED FLOOR. <br />8. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF <br />OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. <br />9. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO <br />NOT INSTALL BACK-TO-BACK. <br />10. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE ONE- <br />PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. <br />11. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT. <br />SPECIAL HAZARDS <br />1. ROOF CONSTRUCTION SUCH AS TELEVISION ANTENNA, GUY WIRES, AND RAZOR RIBBON <br />SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF A FIRE. <br />2. ROOF COVERINGS SHALL CONFORM TO THE BUILDING CODE. <br />3. PROVIDE AN APPROVED SPARK ARRESTOR FOR THE CHIMNEY OF A FIREPLACE, STOVE OR <br />BARBEQUE DEVICE WHICH USES FUEL BURNING MATERIALS. <br />NOTE ON PLANS <br />1. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED <br />2. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT <br />LESS THAN 5 FOOT CANDLES (54 LUX). <br />3. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED <br />IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION IN SECTION 2720. <br />4. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. <br />5. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE <br />AN ILLUMINATION OF NOT LESS THAN 90MIN. IN CASE OF PRIMARY POWER LOSS. <br />(1011.5-1011.6.3) <br />6. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE <br />OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. (1008.1.9) <br />7. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34” <br />AND A MAX. 48” ABOVE THE FINISHED FLOOR. (1008.1.9.2) <br />8. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1008.1.9 <br />9. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL <br />TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS <br />OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAT 1FOOT-CANDLE AT THE <br />WALKING SURFACE. (1006.1) <br />10. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE <br />PROVIDED BY THE PREMISES’ ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY <br />FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE <br />FOLLOWING AREAS (1006.3): <br />A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE <br />TWO OR MORE MEANS OF EGRESS; <br />B. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO <br />HAVE TWO OR MORE EXITS. <br />C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THEIR LEVEL OF EXIT DISCHARGE <br />UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR <br />MORE EXITS. <br />D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1027.1, IN BUILDINGS <br />REQUIRED TO HAVE TWO OR MORE EXITS. <br />E. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.6, FOR EXIT DISCHARGE <br />DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br />11. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR DURATION OF NOT LESS <br />THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN <br />ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN <br />ACCORDANCE WITH SECTION 2702.(1006.3) <br />12. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION <br />THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 LUX) AND A MINIMUM AT ANY POINT <br />OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. <br />ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT -CANDLE (6 LUX) <br />AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE <br />EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION <br />UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. <br />13. THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM <br />PROVIDED FROM STORAGE BATTERIES UNIT EQUIPMENT OR AN ON-SITE GENERATOR SET, <br />AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODE. FOR <br />HIGH RISE BUILDINGS, SEE SECTION 403. <br />SECURITY NOTES <br />1. COORDINATE WITH SECURITY COMPANY FOR INSTALLATION OF ALARM SYSTEMS. <br />2. DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH <br />THE JAMB OR BE PROVIDED WITH SOME DEVICE TO PREVENT THE DOOR FROM BEING <br />OPENED SHOULD THE STOP BE REMOVED. <br />3. STOPS ON OUT-SWINGING DOORS TO BE ONE-PIECE CONSTRUCTION OR FASTENED <br />WITH 3/4" SCREWS 6" O. C. <br />4. ALL PIN-TYPE HINGES ACCESSIBLE FROM THE OUTSIDE WHEN THE DOOR IS CLOSED <br />SHALL HAVE NON-REMOVABLE HINGE PINS OR A MECHANICAL INTERLOCK TO PRECLUDE <br />REMOVAL OF THE DOOR FROM THE EXTERIOR BY REMOVING THE HINGE PINS. IN <br />ADDITION, THEY SHALL HAVE 1/4" MIN. STEEL JAMB STUD WITH 1/4" MIN. PROJECTION. <br />5. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROJECTING <br />DEADBOLTS SHALL BE SECURED TO THE JAMB AND WALL FRAMING WITH 2" LONG <br />SCREWS. (A) THE STRIKE PLATE FOR DEAD BOLTS ON ALL WOOD FRAMED DOORS SHALL <br />BE CONSTRUCTED OF MINIMUM SIXTEEN U.S. GAUGE STEEL, BRONZE, OR BRASS AND <br />SECURED TO THE JAMB BY A MINIMUM OF TWO SCREWS, WHICH MUST PENETRATE AT <br />LEAST TWO INCHES INTO SOLID BACKING BEYOND THE SURFACE TO WHICH THE STRIKE <br />IS ATTACHED. <br />6. ALL EXTERIOR DOORS SHALL BE FLUSH-TYPE HOLLOW METAL OR WOOD DOORS 1-3/4" <br />THICK WITH SOLID CORE CONSTRUCTION, OR FULLY TEMPERED GLASS IF GLASS, AND <br />SHALL BE INSTALLED WITH DEAD LOCKING LATCHES. DEADBOLTS SHALL HAVE A <br />MINIMUM 1" THROW AND A MINIMUM 5/8" EMBEDMENT (STRAIGHT TYPE) AND SHALL <br />CONTAIN HARDENED INSERTS. LOCKS SHALL BE FLUSH, KEY-OPERATED CYLINDERS ON <br />THE EXTERIOR AND SHALL BE OPERABLE WITHOUT KEY, SPECIAL KNOWLEDGE, OR <br />SPECIAL EFFORT ON THE INTERIOR. <br />7. DOOR JAMBS SHALL BE INSTALLED WITH SOLID BACKING IN SUCH A MANNER THAT ANY <br />OPEN SPACE BETWEEN TRIMMERS AND WOOD DOOR JAMBS SHALL BE SOLID SHIMMED <br />BY A SINGLE PIECE EXTENDING NOT LESS THAN TWELVE INCHES ABOVE AND BELOW <br />THE STRIKE PLATE. <br />8. TRIMMERS SHALL BE FULL DOOR LENGTH WITH SOLID BACKING AGAINST SOLE AND <br />HEADER PLATES. <br />9. HORIZONTAL BLOCKING SHALL BE PLACED BETWEEN STUDS AT LOCK STRIKE HEIGHT <br />FOR 3 STUD SPACES <br />10. DOUBLE DOORS (INACTIVE LEAFS) SHALL BE SECURED WITH BOTH HEAD AND BASE <br />FLUSH BOLTS WITH A MINIMUM 5/8" EMBEDMENT. <br />11. NOT LESS THAN THREE FOUR AND ONE-HALF INCH STEEL BUTT HINGES SHALL BE <br />SYMMETRICALLY FASTENED TO BOTH THE DOOR AND FRAME WITH NOT LESS THAN <br />FOUR NO. 9 BY THREE-FOURTHS-INCH WOOD SCREWS OR TO METAL WITH NOT LESS <br />THAN FOUR NO. 8 MACHINE SCREWS. <br />12. KEYING REQUIREMENTS: UPON OCCUPANCY BY THE OWNER OR PROPRIETOR, EACH <br />SINGLE UNIT IN A TRACT OR COMMERCIAL DEVELOPMENT, CONSTRUCTED UNDER THE <br />SAME GENERAL PLAN, SHALL HAVE LOCKS USING COMBINATIONS WHICH ARE <br />INTERCHANGE FREE FROM LOCKS USED IN ALL OTHER SEPARATE DWELLINGS, <br />PROPRIETORSHIPS OR SIMILAR DISTINCT OCCUPANCIES. (ADDED BY ORD. NO. 1945CCS <br />§ 12 (PART), ADOPTED 6/8/99). <br />GENERAL CONSTRUCTION NOTES <br />1. SEE UNIT MATRIX FOR UNIT NUMBERS AND TYPES TO BE UPGRADED. <br />2. ALL ELEVATION DIMENSIONS ARE TO FACE OF FINISH U.O.N. ALL DIMENSIONS ARE TO FACE <br />OF FINISH FOR CLEARANCE PURPOSES, O.U.N. <br />3. CONTRACTOR TO VERIFY IN FIELD ALL DIMENSIONS PRIOR TO CONSTRUCTION. AND TO <br />VERIFY ALL WINDOW LOCATIONS, AND ORIENTATIONS WITHIN UNIT PLANS. CONTRACTOR <br />TO NOTIFY ARCHITECT IF WINDOW LOCATION/SIZE ARE DIFFERENT FROM PLANS. <br />4. CONTRACTOR TO VERIFY EXISTING DOOR HARDWARE AND REPLACE WITH ADA LEVER <br />HARDWARE WITH PUSH BUTTON LOCKS AS REQUIRED. ALL DOORS TO HAVE ACCESSIBLE <br />LEVER-TYPE HARDWARE. ALL DOOR HARDWARE WITH THUMB TURN LOCKS TO BE <br />REPLACED WITH PUSH BUTTON LOCKS. THE LEVER OR LEVER OF ACTUATED LATCHES OR <br />LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2 INCH OF THE DOOR. SEE DOOR <br />SCHEDULE FOR MORE INFO. <br />5. ALL LOW OUTLETS TO BE RAISED/LOWERED, 15" AFF MAX TO BOTTOM OF BOX. CONTROLS, <br />ELECTRICAL OUTLETS, SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE <br />ROOM OR AREA TO CONTROL LIGHTING, ELECTRICAL RECEPTACLES, APPLIANCES OR <br />COOLING, HEATING AND VENTILATION EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 <br />INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES <br />MEASURED FROM THE BOTTOM OF THE OUTLET BOX. RECEPTACLES AT COUNTERS ARE TO <br />BE WITHIN 24" REACH. SEE TYPICAL DETAILS 1/A055. <br />6. ALL INTERIOR DOOR JAMBS TO BE 4" MIN FROM INSIDE CORNER OR CENTERED IN WALL <br />UNLESS NOTED OTHERWISE INTERIOR DIMENSIONS ARE TO FACE OF FINISH U.N.O. <br />7. ALL MECHANICAL, PLUMBING & ELECTRICAL PENETRATIONS THROUGH RATED ASSEMBLIES <br />SHALL BE FIRE STOPPED. <br />8. IF APPLICABLE, PATCH GYP-CRETE, CONCRETE @ FLOOR WHERE WALLS ARE <br />REMOVED.WHEN LOCATING NEW WALLS ON EXISTING GYP-CRETE PRE-DRILL GYP-CRETE <br />AND SCREW BOTTOM PLATE TO SUBFLOOR. WHEN LOCATING ATTACHMENTS IN POST <br />TENSION SLAB - XRAY OR SIMILAR TO LOCATE POSSIBLE POST TENSION CABLES IN AREAS <br />OF WORK. <br />9. AT SHOWERS/TUBS CONTRACTOR TO VERIFY MANUFACTURER'S CLEAR DIMENSION <br />REQUIREMENTS PRIOR TO START OF FRAMING. WHEN CALLED OUT TILE AT SHOWERS/TUBS <br />TO EXTEND TO CEILING AND OUT TO ENDS OF ADJ. WALLS AND BE TERMINATED WITH A <br />BULLNOSE. ALL GYPSUM BOARD BEHIND SHOWERS TO BE WATER RESISTANT GYP BD. <br />PROVIDE RATED BOARD WHERE REQUIRED. SHOWER AND TUB WALLS TO BE SMOOTH, <br />HARD, NON-ABSORBANT SURFACE NOT LESS THAN 70" ABOVE DRAIN INLET. <br />10. RESTORE ALL FINISHES AND MATCH EXISTING (IF APPLICABLE) FOR ALL COLORS, TRIM, ETC <br />(UNLESS OTHERWISE NOTED). REPAIR ALL DAMAGE TO LIKE NEW CONDITION. SEAL <br />EXTERNAL CRACKS, JOINTS, ETC WITH CAULKING AND INSTALL PEST PROOF SCREENS <br />WHERE REQUIRED. <br />11. PAINT AT ALL DRYWALL PATCHES SHOULD INCLUDE THE ENTIRE WALL TO CLOSEST <br />INTERSECTION NOT JUST THE AREA OF THE PATCH. <br />12. CONTRACTOR TO MAINTAIN THE INTEGRITY OF ALL FIRE RATINGS. <br />13. SEE A050-A055 FOR MOUNTING HEIGHT, CLEARANCES, & ACCESSIBILITY INFO. ALL <br />THRESHOLDS TO MEET CBC 1132A. REFER TO SHEETS A620-A630 FOR DOOR THRESHOLD <br />TRANSITION REQUIREMENTS. <br />14. ANY EQUIPMENT, GRAB BARS, ACCESSORIES, APPURTENANCES MOUNTED ON STUD WALLS <br />ARE REQUIRED TO BE ATTACHED TROUGH WALL FINISH INTO SOLID BLOCKING U.O.N BY <br />MANUFACTURER SPECIFICALLY. PROVIDE 2 X 8 MIN. BLOCKING @ ALL GRAB BAR LOCATIONS <br />& WHERE SHOWN. SEE TYP. DETAILS. <br />15. VERIFY ALL EQUIPMENT SIZES BEFORE FABRICATION OF CASEWORK, BUILT-IN KITCHEN <br />EQUIPMENT/APPLIANCES (REF, RANGE, MICROWAVE, ETC) & ALL OTHER BUILT-IN TYPE <br />EQUIPMENT SHALL FIT AS TIGHTLY AS POSSIBLE WITHIN EQUIP/APPLIANCE MFR'S <br />REQUIREMENTS TO CASEWORK OPENINGS. <br />16. ANY SUBCONTRACTOR DESIGNED ITEMS TO BE SUBMITTED TO AND APPROVED BY THE <br />ARCHITECT PRIOR CONSTRUCTION. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL <br />CABINETRY/CASEWORK, AND SUBMITTALS FOR APPROVAL FOR ALL FINISHES, APPLIANCES <br />AND PLUMBING FIXTURES. <br />17. PROVIDE BLOCKING FOR ALL CASEWORK, COORDINATE LOCATION WITH CASEWORK <br />MANUFACTURER. <br />18. FLOOR / WALL / CABINET FINISHES TO EXTEND TO BACK WALL AT OPEN SINK, FRIDGE AND <br />WORK STATION BASE CABINETS <br />19. PROVIDE SOLID END PANELS AT OPEN WORK STATIONS AND KITCHEN SINKS WHERE BASE <br />CABINET FINISHED SIDES DO NO OCCUR <br />20. CARE HAS BEEN TAKEN TO FORESEE PERTINENT CONSTRUCTION CONDITIONS. HOWEVER, <br />FIELD CONDITIONS MAY OCCUR WHICH WILL CAUSE A CONFLICT. IT IS THE RESPONSIBILITY <br />OF THE GENERAL CONTRACTOR OR THEIR SUBCONTRACTOR TO ALERT THE ARCHITECT OF <br />ANY SUCH DISCREPANCIES OR CONFLICTS PRIOR TO PERFORMING WORK. FAILURE TO DO <br />SO MAY LEAD TO WORK IN QUESTION BEING REJECTED BY OWNER OR ARCHITECT. <br />21. CLOSET POLE AND SHELF- PROVIDE CONCEALED 2x BLOCKING WITHIN WALLS FOR SHELF <br />AND POLE BRACKET SUPPORT VERIFY LOCATION REQUIREMENTS WITH SUPPLIER. AT <br />SINGLE SHELF AND POLE SET BLOCKING FOR POLE AT 46" A.F.F. AT DOUBLE SHELVES AND <br />POLES SET BLOCKING FOR TOP POLE AT 80" AND LOWER POLE AT 40" A.F.F. SHELVES TO BE <br />5/8'' THK. WOOD FACTORY PRIMED FIELD PAINTED. AT COAT CLOSET, PROVIDE SHELF AND <br />POLE. AT BEDROOM CLOSET, PROVIDE DOUBLE SHELVES AND DOUBLE POLE. <br />GENERAL DEMO NOTES <br />1. REMOVE/RELOCATE EXISTING LIGHTING FIXTURES, SWITCHES, OUTLETS EFFECTED BY <br />WALL CHANGES. ADJUST LOCATION AND REPLACE AS NECESSARY. <br />2. PROVIDE TEMPORARY SHORING AND SUPPORTING STRUCTURE WHERE REQUIRED TO <br />SUPPORT STRUCTURAL LOADS DURING DEMO. <br />3. CONTRACTOR TO REMOVE A PORTION OF THE CEILING IN THE AREA OF THE WALL <br />DEMOLITION AND VERIFY THE DIRECTION OF THE EXISTING FRAMING WHEN DEMO A <br />PORTION OF CEILING. CONTRACTOR IS TO NOTIFY ARCHITECT WHEN INFORMATION <br />IMMEDIATELY. <br />4. CONTRACTOR TO REMOVE A PORTION OF THE WALL FINISH TO DETERMINE IF THERE IS <br />EXISTING PLYWOOD ON EITHER FACE OF THE WALL WHEN DEMO A PORTION OF WALL. IF <br />PLYWOOD IS FOUND THE STRUCTURAL ENGINEER SHALL BE NOTIFIED TO VERIFY <br />THICKNESS AND NAILING OF WALL BEFORE PROCEEDING WITH DEMOLITION. <br />5. CONTRACTOR TO DETERMINE IF FLOOR JOISTS ARE SPLICED OR BLOCKED OVER WALLS TO <br />BE REMOVED OR DEMOLISHED. IF THERE IS A SPLICE OR BLOCKING AT THE TOP OF THE <br />WALL CONTRACTOR TO NOTIFY ARCHITECT AND ENGINEER FOR DIRECTION BEFORE <br />PROCEEDING WITH DEMOLITION.DEMOLITION CONTRACTOR IS NOT TO REMOVE ANY <br />STRUCTURAL ELEMENTS WITHOUT PRIOR DIRECTION AND AUTHORIZATION BY A <br />STRUCTURAL ENGINEER. <br />6. WALLS TO BE DEMOLISHED ARE NON-BEARING AND NON-SHEAR, AND THIS HAS BEEN <br />VERIFIED BY THE ARCHITECT OF RECORD VIA SITE VISIT OR AS-BUILT. TO COMPLY WITH <br />APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO <br />SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. <br />7. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS BY APPLICABLE CODES <br />AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. <br />8. ERECT AND MAINTAIN DUSTPROOF PARTITIONS TO PREVENT SPREAD OF DUST, FUMES, AND <br />SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS <br />AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. <br />9. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS <br />AT NO COST TO THE OWNER. <br />10. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND <br />OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. <br />11. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES <br />FOR NEW WORK. REMOVE ALL POWER SIGNAL, SWITCHING & OTHER PERTINENT ITEMS <br />FROM WALLS TO BE DEMOLISHED. <br />12. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. REMOVE ABANDONED <br />ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. <br />13. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR FOR NEW FLOOR FINISHES. <br />14. PATCH OR REPAIR THE DRYWALL (WALL AND CEILINGS) MISSING AND/OR DAMAGED AT <br />DEMOLISHED WALLS AND/OR CEILINGS. REPLACE SUBFLOORING, FLOORING, AND/OR <br />BASEBOARD MISSING, REMOVED AND/OR DAMAGED AT DEMOLISHED WALLS. <br />15. CARE SHOULD BE MADE IN CAPPING OFF ALL UNUSED ELECTRICAL AND PLUMBING <br />FEEDS. WHERE POSSIBLE ALL ABANDONED UTILITY FEEDS TO BE REMOVED BACK TO THE <br />SOURCE OF ORIGINATION. <br />16. REMOVE ALL ELECTRICAL CIRCUITS NOT ATTACHED TO FUNCTIONING EQUIPMENT THAT IS <br />TO REMAIN. REMOVE THEM BACK TO PANELS. ALSO REMOVE CONDUITS WHERE POSSIBLE. <br />17. CARE TO BE TAKEN DURING WALL DEMOLITION WHERE NEW WALL CONSTRUCTION IS <br />PROPOSED TO INTERSECT OR JOIN EXISTING OR ADJACENT CONSTRUCTION. <br />18. THE PREMISES AND THE JOB SITE SHALL BE MAINTAINED IN A REASONABLY NEAT AND <br />ORDERLY CONDITION AND LEFT FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND <br />RUBBISH DURING THE ENTIRE CONSTRUCTION PERIOD. REMOVE CRATES, CARTONS, AND <br />OTHER FLAMMABLE WASTE MATERIALS OR TRASH FROM THE WORK AREA AT THE END OF <br />EACH WORKING DAY. PIPE AND DUCT SHAFTS, CHASES, FURRED SPACES, AND SIMILAR <br />SPACES SHALL BE CLEANED AND LEFT FREE OF RUBBISH, LOOSE PLASTER, MORTAR <br />DRIPPINGS, EXTRANEOUS CONSTRUCTION MATERIAL, DIRT, AND DUST. <br />19. CONDUCT DEMOLITION TO AVOID DAMAGE TO EXISTING BUILDING SHELL/ STRUCTURE. <br />CEASE OPERATION AND NOTIFY OWNER IMMEDIATELY IF SHELL/ STRUCTURE APPEARS TO <br />BE IN DANGER. <br />20. THE CONTRACTOR'S DISCRETION IS REFERRED TO FOR INTERPRETATION OF THE LIMITS <br />UNDER WHICH THEY TREAT WALLS WHICH ARE TO REMAIN. WHETHER TO DEMOLISH AN <br />ENTIRE WALL TO BE REUSED OR TO PROVIDE SELECTIVE DEMOLITION. <br />21. AT AREAS OF DRYWALL ONLY DEMO, NOTE MAKE-UP OF ASSEMBLY (NUMBER OF LAYERS OF <br />GYP, RESILIENT CHANNELS, ETC.) SO THAT ASSEMBLY CAN BE MATCH DURING NEW <br />CONSTRUCTION. <br />SOUND <br />1. ALL PENETRATIONS INTO SOUND RATED PARTITIONS OR FLOOR-CEILING ASSEMBLIES WILL <br />BE SEALED WITH APPROVED PERMANENT ACOUSTIC RESILIENT SEALANT. <br />2. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES, APPLIANCE VENTS LOCATED IN SOUND <br />ASSEMBLIES SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF <br />RESILIENT SLEEVES, MOUNTS OR MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL. <br />3. AN APPROVED PERMANENT AND RESILIENT ACOUSTICAL SEALANT WILL BE PROVIDED <br />ALONG THE JOINT BETWEEN THE FLOOR AND THE SEPARATION WALLS <br />4. MINERAL FIBER INSULATION WILL BE INSTALLED IN JOIST SPACES WHEREVER PLUMBING <br />PIPING OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH UNIT PASSES <br />THROUGH THE PLANE OF THE FLOOR-CEILING ASSEMBLY FROM WITHIN A WALL. THE <br />INSULATION SHALL BE INSTALLED TO A POINT 12" BEYOND THE PIPE OR DUCT. <br />5. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS WILL BE <br />SEPARATED HORIZONTALLY BY 24" AND BACK AND SIDES OF BOXES WILL BE SEALED WITH <br />1/8" RESILIENT SEALANT AND BACKED BY A MINIMUM OF 2" THICK MATERIAL FIBER <br />INSULATION. TV, TELEPHONE AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES <br />ACCORDINGLY. <br />INTERIOR ENVIROMENT/INTERIOR FINISHES <br />1. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL <br />LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION 1205.2 <br />OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN <br />AVERAGE ILLUMINATION OF 10 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT <br />OF 30 INCHES ABOVE FLOOR LEVEL. (1205.1 AND 1205.3) <br />2. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS SHALL BE TESTED AS <br />SPECIFIED IN SECTION 802. IN ADDITION, APPLICATIONS ARE TO BE IN ACCORDANCE WITH <br />SECTION 803. 804, AND TABLE 803.5. <br />3. ANY DECORATIONS SHALL BE NONCOMBUSTIBLE OR FLAME-RETARDANT TREATED IN AN <br />APPROVED MANNER ( CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) <br />4. THE FLAME SPREAD RATING OF PANELING MATERIALS ON THE WALLS OF THE CORRIDOR, <br />LOBBY & EXIT ENCLOSURE MUST BE IDENTIFIED ON THE PLANS. <br />5. ADD NOTE ON PLAN: WALL, FLOOR AND CEILING FINISHES SHALL NOT EXCEED THE FLAME <br />SPREAD CLASSIFICATIONS IN CBC 803.9. <br />6. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS <br />SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS <br />THAN 72" IN ABOVE DRAIN INLET. <br />FIRE RESISTANT RATED CONSTRUCTION <br />FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH SECTION 718 AT THE <br />FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED <br />SPACES, AT THE CEILING AND FLOOR LEVELS. 718.2.2 <br />B. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED <br />SPACES, AT 10-FOOT INTERVALS ALONG THE LENGTH OF THE WALL. 718.2.2 <br />C. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND <br />HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE <br />CEILINGS AND SIMILAR LOCATIONS. 718.2.3 <br />D. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM <br />OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF STAIRS <br />IF THE WALL UNDER THE STAIRS IS UNFINISHED. 718.2.4 <br />E. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND <br />SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR <br />LEVELS, WITH NONCOMBUSTIBLE MATERIALS. 718.2.5 <br /> <br />1128 W Highland St <br />3/27/2025