Laserfiche WebLink
Highland Manor <br />1128 Highland St <br />Santa Ana, CA, 92703 <br />SHEET NUMBER <br />SH <br />E <br />E <br />T <br /> <br />TI <br />T <br />L <br />E <br />24 <br />2 <br />6 <br />A <br />DAT <br />E <br />JO <br />B <br /> <br />NO. <br />DR <br />A <br />W <br />N <br />PROJECT NAME <br />PROJECT ADDRESS <br />DR <br />A <br />W <br />I <br />N <br />G <br /> <br />LO <br />G <br />DA <br />T <br />E <br />ID <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />12 <br />/ <br />1 <br />2 <br />/ <br />2 <br />4 <br />12 <br />/ <br />2 <br />3 <br />/ <br />2 <br />4 <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />5 <br />01 02 03 <br />PL <br />A <br />N <br />N <br />I <br />N <br />G <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />PR <br />E <br />L <br />I <br />M <br />I <br />N <br />A <br />R <br />Y <br /> <br />B <br />AN <br />D <br /> <br />S <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />B <br />AN <br />D <br /> <br />S <br />CO <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />#1 <br />A041 <br />DI <br />S <br />A <br />B <br />L <br />E <br />D <br /> <br />AC <br />E <br />S <br />S <br />I <br />B <br />L <br />E <br /> <br />NO <br />T <br />E <br />S <br />JR <br />, <br /> <br />LF <br />NL <br />ALL IDEAS, DESIGNS, ARRANGEMENTS <br />AND PLANS INDICATED OR REPRESENTED <br />BY THIS DRAWING ARE OWNED BY AND <br />PROPERTY OF BELL DESIGN GROUP AND <br />WERE CREATED, EVOLVED AND <br />DEVELOPED FOR USE ON AND IN <br />CONNECTION WITH THE SPECIFIED <br />PROJECT. NONE OF SUCH IDEAS, <br />DESIGNS, ARRANGEMENTS, OR PLANS <br />SHALL BE USED BY OR DISCLOSED TO <br />ANY PERSON, FIRM OR CORPORATION <br />FOR ANY PURPOSE WHATSOEVER <br />WITHOUT THE WRITTEN PERMISSION OF <br />BELL DESIGN GROUP. WRITTEN <br />DIMENSIONS SHALL TAKE PRECEDENCE <br />OVER SCALED DIMENSIONS. <br />CONTRACTOR SHALL VERIFY AND BE <br />RESPONSIBLE FOR ALL DIMENSIONS AND <br />CONDITIONS ON THE JOB, AND THIS <br />OFFICE MUST BE NOTIFIED OF ANY <br />VARIATIONS FROM DIMENSIONS AND <br />CONDITIONS SHOWN BY THESE <br />DRAWINGS. <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br />: <br /> <br />re <br />l <br />a <br />t <br />i <br />v <br />i <br />t <br />y <br /> <br />- <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br /> <br />So <br />f <br />t <br />w <br />a <br />r <br />e <br /> <br />as <br /> <br />a <br />Se <br />r <br />v <br />i <br />c <br />e <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br /> <br /> <br /> <br />2/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />5: <br />2 <br />4 <br /> <br />PM <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FIGURE 11 B-304.3.2 <br />T-SHAPEQ TURNING SPACE <br />dimension showing English units (in <br />inches unless otherwise specified) <br />above the line and SI units (in <br />millimeters unless otherwise specified) <br />below the line <br />dimension for small measurements <br />dimension showing a range with <br />minimum - maximum <br />minimum <br />maximum <br />greater than <br />greater than or equal to <br />less than <br />less than or equal to <br />boundary of c lear floor space or <br />maneuvering clearance <br />centerline <br />a permitted element or its extension <br />direction of travel or approach <br />a wall floor, ceiling or other element <br />cut in section or plan <br />a highlighted element in <br />elevation or plan <br />location zone of element, control or <br />feature <br />DescriptionConvention <br />forward parallel <br />36 <br />914 <br />6 <br /> 152 <br />33-36 <br />838-914 <br />min <br />max <br />> <br />> <br />< <br />< <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br />  <br /> <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br />INFORMATION BULLETIN / PUBLIC - BUILDING CODE <br />REFERENCE NO.: LABC Sec. 11B-304,305,404 Effective: 01/01/2020 <br />DOCUMENT NO.: P/BC 2020-086 Revised: <br />Previously Issued As: P/BC 2017-086 <br />ACCESSIBILITY DETAILS<br /> <br />FOR DOORS, MANEUVERING SPACES & ROUTES<br /> <br />30 <br />" <br /> <br />M <br />I <br />N <br /> <br />UNLESS SPECIFICALLY STATED OTHERWISE, FIGURES ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY. (11B-104.3 FIGURES) <br />(b) T-SHAPED SPACE FOR 180O TURNS <br />(a) 60 INCHES DIAMETER SPACE <br />WHEELCHAIR <br />TURNING SPACE <br />FIGURE 11B-104 <br />GRAPHIC CONVENTION <br />FOR FIGURES <br />48" MIN <br />FIGURE 11B-305.3 <br />CLEAR FLOOR OR GROUND SPACE <br />FIGURE 11B-305.5 <br />POSITION OF CLEAR <br />FLOOR OR GROUND <br />SPACE <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 1 of 7 <br />RUBBER BUMPER ON CHAIR <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br /> <br />  <br />  <br /> <br />  <br /> <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br /> <br />  <br />  <br />  <br /> <br />  <br /> <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />   <br /> <br /> <br />  <br />  <br />  <br /> <br /> <br />  <br />  <br />  <br /> <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE <br />INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />DOORS & MANEUVERING SPACE<br /> <br />60 <br />" <br /> <br />M <br />I <br />N <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />PULL SIDE <br />24" MIN <br />18" MIN <br />CLEAR AT EXTERIOR DOORS <br />CLEAR AT INTERIOR DOORS <br />PROVIDE THIS ADDITIONAL <br />SPACE IF DOOR IS <br />EQUIPPED WITH BOTH A <br />LATCH AND A CLOSER <br />PUSH SIDE <br />12" MIN <br />FRONT APPROACH <br />10" MIN. BOTTOM RAIL <br />DOOR CONSTRUCTION <br />60 <br />" <br />MI <br />N <br />44 <br />" <br />MIN <br />48 <br />" <br /> <br />M <br />I <br />N <br />22" MIN 22" MIN36" MIN <br />HINGE APPROACH, PULL SIDE HINGE APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE, DOOR <br />PROVIDED WITH BOTH CLOSER AND LATCH <br />FIGURE 11B-404.2.4.1 <br />MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 2 of 7 <br />latch approach, push side <br />latch approach, push side, <br />door provided with closer <br />(C) <br />folding door <br />(b) <br />sliding door <br />(a) <br />hinged door <br />FIGURE 11B-404.2.4.1—continued <br />MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <br />  <br />  <br /> <br /> <br />  <br /> <br />  <br /> <br />  <br />  <br /> <br /> <br /> <br />  <br /> <br /> <br />  <br /> <br />  <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE <br />INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />DOORS & MANEUVERING SPACE<br /> <br />FIGURE 11B-404.2.3<br /> <br />CLEAR WIDTH OF DOORWAYS<br /> <br />TABLE 11B-404.2.3<br /> <br />MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES<br /> <br />TYPE OF USE MINIMUM MANEUVERING CLEARANCE <br />APPROACH DIRECTION DOOR or GATE SIDE PERPENDICULAR TO <br />DOORWAY <br />PARALLEL TO DOORWAY <br />(beyond latch side unless noted) <br />From front Pull 60 inches 18 inches <br />From front Push 48 inches 0 inches <br />From hinge side Pull 60 inches 36 inches <br />From hinge side Push 44 inches 22 inches <br />From latch side Pull 60 inches 24 inches <br />From latch side Push 44 inches 24 inches <br />1. ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED. <br />2. ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED. <br />3. BEYOND HINGE SIDE. <br />4. ADD 4 INCHES IF CLOSER IS PROVIDED. <br />5. ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 3 of 7 <br />latch approach, push side <br />latch approach, push side, <br />door provided with closer <br />(C) <br />folding door <br />(b) <br />sliding door <br />(a) <br />hinged door <br />FIGURE 11B-404.2.4.1—continued <br />MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <br />  <br />  <br /> <br /> <br />  <br /> <br />  <br />   <br />  <br /> <br /> <br /> <br />  <br /> <br /> <br />  <br /> <br />  <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE <br />INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />DOORS & MANEUVERING SPACE<br /> <br />FIGURE 11B-404.2.3<br /> <br />CLEAR WIDTH OF DOORWAYS<br /> <br />TABLE 11B-404.2.3<br /> <br />MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES<br /> <br />TYPE OF USE MINIMUM MANEUVERING CLEARANCE <br />APPROACH DIRECTION DOOR or GATE SIDE PERPENDICULAR TO <br />DOORWAY <br />PARALLEL TO DOORWAY <br />(beyond latch side unless noted) <br />From front Pull 60 inches 18 inches <br />From front Push 48 inches 0 inches <br />From hinge side Pull 60 inches 36 inches <br />From hinge side Push 44 inches 22 inches <br />From latch side Pull 60 inches 24 inches <br />From latch side Push 44 inches 24 inches <br />1. ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED. <br />2. ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED. <br />3. BEYOND HINGE SIDE. <br />4. ADD 4 INCHES IF CLOSER IS PROVIDED. <br />5. ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 3 of 7 <br />(C) <br />push side, door provided with <br />both closer and latch <br />(b) <br />push side <br />(a) <br />pull side <br />  <br />  <br /> <br /> <br />  <br /> <br />  <br />  <br />   <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br />  <br />  <br />  <br /> <br /> <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED <br />ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />DOORS & MANEUVERING SPACE<br /> <br />48" MIN 48" MIN <br />(a) (b)<br /> <br />48" MIN <br />(c) <br />FIGURE 11B-404.2.6<br /> <br />DOORS IN SERIES AND GATES IN SERIES<br /> <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 5 of 7 <br />(a ) SINGLE DOOR <br />(b) DOUBLE DOOR <br />(C)PASSA dominant direction of travel <br />AN ADULT SIZE WHEELCHAIR AVERAGES 27 INCHES <br />IN WIDTH. THE REQUIRED 32 INCH CLEAR OPENING <br />ALLOWS 2-1/2 INCHES ON EACH SIDE FOR HANDS. <br />long dimension perpendicular to <br />dominant direction of travel <br />FIGURE 11B-302.2 <br />CARPET PILE HEIGHT <br />FIGURE11B-303.2 <br />VERTICAL CHANGE IN LEVEL <br />FIGURE 11B-303.3 <br />BEVELED CHANGE IN LEVEL <br />FIGURE 11B-302.3 <br />ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES <br /> <br /> <br /> <br />  <br />  <br />11B-404.2.3 <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />* NOTE: <br />SEE FIGURE 11B-404.2.3 <br /> <br /> <br /> <br />  <br /> <br />  <br />  <br />  <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br />  <br />   <br />  <br />  <br />  <br />  <br />   <br /> <br /> <br /> <br /> <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />ACCESSIBLE ROUTES<br /> <br />11B-404.2.3 <br />Door openings shall provide a clear <br />width of 32 inches minimum. Clear <br />openings of doorways with swinging <br />doors shall be measured between the <br />face of the door and the stop, with the <br />door open 90 degrees. Openings more <br />than 24 inches deep shall provide a <br />clear opening of 36 inches minimum. <br />There shall be no projections into the <br />required clear opening width lower than <br />34 inches above the finish floor or <br />ground. Projections into the clear <br />opening width between 34 inches and <br />80 inches above the finish floor or <br />ground shall not exceed 4 inches. <br />11B-404.2.5 <br />THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 <br />INCH HIGH MAXIMUM. RAISED THRESHOLDS AND <br />CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH <br />SECTIONS 11B-302 AND 11B-303. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 6 of 7 <br />(a) <br />180 degree turn <br />(b) <br />180 degree turn <br />(Exception) <br />(a) <br />single space <br />(b) <br />two spaces <br />(b) <br />side <br />entry <br />(a) <br />front or rear <br />entry <br />FIGURE 11B-802.1.2 <br />WIDTH OF WHEELCHAIR SPACES <br />FIGURE 11B-802.1.3 <br />DEPTH OF WHEELCHAIR SPACES <br />FIGURE 11B-403.5.1 <br />CLEAR WIDTH OF AN ACCESSIBLE ROUTE <br />FIGURE 11B-403.5.2 <br />CLEAR WIDTH AT TURN <br /> <br /> <br /> <br />  <br />  <br />  <br /> <br /> <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />  <br /> <br />  <br /> <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br />P/BC 2020-086 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />ACCESSIBLE ROUTES<br /> <br />ACCESSIBLE ROUTE OF TRAVEL <br />11B-403.5.1<br /> <br />SEE CLEAR WIDTH AND EXCEPTIONS <br /> <br />REQUIREMENTS<br /> <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 7 of 7 <br /> <br /> <br /> <br />  <br />  <br /> <br /> <br />   <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br />INFORMATION BULLETIN / PUBLIC - BUILDING CODE <br />REFERENCE NO.: LABC Sec.11B-607,608,610 Effective: 01/01/2020 <br />DOCUMENT NO.: P/BC 2020-088 <br />Previously Issued As: P/BC 2017-088 Revised: <br />ACCESSIBILITY DETAILS FOR TUBS AND SHOWERS <br /> <br />FIGURE 11B-607.2<br /> <br />CLEARANCE FOR BATHTUBS <br /> <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED<br /> <br />ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION.<br /> <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide reasonable <br />accommodation to ensure equal access to its programs, services and activities. <br />Page 1 of 5 <br />FIGURE 11B-607.5 <br />BATHTUB CONTROL LOCATION <br />FIGURE 11B-607.4.1 <br />GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS <br />FIGURE 11B-607.4.2<br /> <br />GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS<br /> <br /> <br /> <br /> <br />  <br />  <br /> <br /> <br />  <br /> <br />  <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br />P/BC 2020-088 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED <br />ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />TUBS AND SHOWERS <br />11B-607.5 Controls, other than drain stoppers, shall be <br />located on an end wall. Controls shall be between the <br />bathtub rim and grab bar, and between the open side of <br />the bathtub and the centerline of the width of the <br />bathtub. Controls shall comply with Section 11B-309.4. <br />11B-607.6 A shower spray unit with a hose 59 inches <br />(1499 mm) long minimum that can be used both as a <br />fixed-position shower head and as a handheld shower <br />shall be provided. The shower spray unit shall have an <br />on/off control with a non-positive shut-off. If an <br />adjustable-height shower head on a vertical bar is used, <br />the bar shall be installed so as not to obstruct the use of <br />grab bars. Bathtub shower spray units shall deliver <br />water that is 120ᄚF (49ᄚC) maximum. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 2 of 5 <br />Note: inside finished dimensions measured at the center points <br />ofopposing sides <br />FIGURE 11B-608.2.1 <br />TRANSFER TYPE SHOWER <br /> <br />COMPARTMENT SIZE AND CLEARANCE<br /> <br />Note: inside finished dimensions measured at the center <br />points ofopposing sides <br />FIGURE 11B-608.2.2<br /> <br />STANDARD ROLL-IN TYPE<br /> <br />SHOWER COMPARTMENT SIZE AND CLEARANCE<br /> <br />Note inside finished dimensions measured at the center <br />points of opposing sides <br />FIGURE 11B-608.2.3 <br />ALTERNATE ROLL-IN TYPE <br />SHOWER COMPARTMENT SIZE AND CLEARANCE <br />FIGURE 11B-608.3.2<br /> <br />GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER<br /> <br />FIGURE 11B-608.3.3<br /> <br />GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS<br /> <br />  <br /> <br /> <br />  <br /> <br /> <br /> <br />  <br />  <br /> <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br />P/BC 2020-088 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY AS <br />AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />TUBS AND SHOWERS<br /> <br />Note: Transfer type shower <br />compartments shall <br />be permitted in transient <br />lodging guest rooms, <br />multibedroom housing <br />units in undergraduate <br />student housing and <br />residential dwelling units; <br />and shall not be permitted <br />at other locations to meet <br />the requirements of Section <br />11B-213.3.6. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br /> 3 of 5 <br /> <br /> <br /> <br /> <br /> <br />  <br />  <br />  <br />  <br /> <br />  <br /> <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br />P/BC 2020-088 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />TUBS AND SHOWERS <br />FIGURE 11B-608.5.1 <br />TRANSFER TYPE SHOWER <br />COMPARTMENT CONTROL FIGURE 11B-608.5.3 <br />ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT <br />CONTROL LOCATION <br />FIGURE 11B-608.5.2 <br />STANDARD ROLL-IN TYPE <br />SHOWER COMPARTMENT CONTROL <br />LOCATIONLOCATION FIGURE 11B-610.2 BATHTUB SEATS <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 4 of 5 <br />FIGURE 11B-610.3.1 <br />RECTANGULAR SHOWER SEAT <br />FIGURE 11B-610.3 <br />EXTENT OF SEAT <br />FIGURE 11B-610.3.2 <br />L-SHAPED SHOWER SEAT <br /> <br /> <br />  <br />  <br />  <br /> <br />  <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />  <br /> <br /> <br /> <br /> <br />  <br />  <br />  <br />  <br /> <br /> <br /> <br />P/BC 2020-088 <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />TUBS AND SHOWERS <br />11B-610.1 General. Seats in bathtubs and shower <br />compartments shall comply with Section 11B-610. <br />11B-610.2 Bathtub seats. The top of bathtub seats shall be <br />17 inches minimum and 19 inches maximum above the <br />bathroom finish floor. The depth of a removable in-tub seat <br />shall be 15 inches (381 mm) minimum and 16 inches <br />maximum. The seat shall be capable of secure placement. <br />Permanent seats at the head end of the bathtub shall be 15 <br />inches deep minimum and shall extend from the back wall to <br />or beyond the outer edge of the bathtub. <br />11B-610.3 Shower compartment seats. A seat in a standard <br />roll-in shower compartment shall be a folding type, shall be <br />installed on the side wall adjacent to the controls, and shall <br />extend from the back wall to a point within 3 inches of the <br />compartment entry. A seat in an alternate roll-in type <br />shower compartment shall be a folding type, shall be <br />installed on the front wall opposite the back wall, and shall <br />extend from the adjacent side wall to a point within 3 inches <br />of the compartment entry. In transfer type showers, the <br />seat shall extend from the back wall to a point within 3 <br />inches(76 mm) of the compartment entry. The top of the <br />seat shall be 17 inches minimum and 19 inches <br />maximum above the bathroom finish floor. When folded, <br />the seat shall extend 6 inches maximum from the mounting <br />wall. Seats shall comply with Section 11B-610.3.1 or 11B- <br />610.3.2. <br />11B-610.3.1 Rectangular seats. The rear edge of a <br />rectangular seat shall be 21/2 inches maximum and the front <br />edge 15 inches minimum and 16 inches maximum from the <br />seat wall. The side edge of the seat shall be 11/2 inches <br />maximum from the adjacent wall. <br />11B-610.3.2 L-shaped seats. The rear edge of an L-shaped <br />seat shall be 21/2 inches maximum and the front edge 15 <br />inches minimum and 16 inches maximum from the seat wall. <br />The rear edge of the “L” portion of the seat shall be 11/2 <br />inches maximum from the wall and the front edge shall be <br />14 inches minimum and 15 inches maximum from the wall. <br />The end of the “L” shall be 22 inches minimum and 23 inches <br />maximum from the main seat wall. <br />11B-610.4 Structural strength. Allowable stresses shall not <br />be exceeded for materials used when a vertical or horizontal <br />force of 250 pounds (1112 N) is applied at any point on the <br />seat, fastener, mounting device, or supporting structure. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 5 of 5 <br />FIGURE 11B-703.3.2 <br />POSITION OF BRAILLE <br />FIGURE 11B-703.4.2 <br />LOCATION OF TACTILE SIGNS AT DOORS <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />P/BC 2020-091 <br />THESE DIAGRAMS ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />HEIGHT OF TACTILE CHARACTERS<br /> <br />ABOVE FINISH FLOOR OR GROUND<br /> <br />TABLE 11B-703.4.1 <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on t he basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 3 of 5 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />P/BC-2020-091 <br />THESE DIAGRAMS ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY <br />AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. <br />TOILETS AND BATHING FACILITIES GEOMETRIC SYMBOLS<br /> <br />FLOOR <br />60 <br />" <br /> <br />M <br />A <br />X <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />X <br />GENDER SPECIFIC GEOMETRIC <br />SYMBOLS APPLY ONLY TO <br />MULTI-ACCOMMODATION <br />RESTROOMS <br />MEN WOMEN <br />SINGLE-USER SIGN STATEMENT AS - <br />“UNISEX RESTROOM”, “ALL GENDER <br />RESTROOM”, “RESTROOM” (TACTILE/ <br />BRAILLE COMPLIANT <br />RESTROOM UNSEX <br /> RESTROOM <br />UNISEX <br />RESTROOM Y <br />CENTER LINE <br />FIN. ELEV. <br />12 <br />" <br /> <br />NOTE: PICTOGRAMS NOT REQUIRED <br />The provisions of CBC Chapter 11B require that a sanitary facility that is not specifically <br />identified as for "men" or "women" (referred to in Chapter 11B as a “unisex” facility) <br />have a geometric symbol on the door that is an equilateral triangle superimposed onto <br />a circle. The "unisex" symbol is the only specific indicator required to be provided by <br />Chapter 11B for a toilet facility that is available for use by all individuals. No pictogram, <br />text, or braille is required on the symbol. (See attachment, Exhibit A.) <br />BASELINE OF THE <br /> <br />HIGHEST LINE OF<br /> <br />RAISED CHARACTERS<br /> <br />X <br />BASELINE OF LOWEST Y <br />UNISEX <br />RESTROOM <br />BRAILLE CELL <br />TACTILE / RAISED CHARACTER & GD-II BRAILLE SIGN <br />11B-703.4.1 Height above finish floor or ground. <br />Tactile characters on signs shall be located 48 inches (1219 mm) minimum <br />above the finish floor or ground surface, measured from the baseline of the <br />lowest Braille cells and 60 inches (1524 mm) maximum above the finish floor or <br />ground surface, measured from the baseline of the highest line of raised <br />characters. Exception: Tactile characters for elevator car controls shall not be <br />required to comply with Section 11B- 703.4.1. 1 <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide <br />reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 4 of 5<br /> <br />1128 W Highland St <br />3/27/2025