Laserfiche WebLink
PAGE <br />REV: C 4/8/2025 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />ANGELA SAMPSON <br />3340 S CRAWFORD GLEN,  <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br />  109R-340SAMP <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 642-8754 <br />APN: 412-521-03 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />PV-4.2 <br />ELECTRICAL CALCS <br />SYSTEM INFORMATION <br />9.6 KW DC PHOTOVOLTAIC SYSTEM <br />     (8) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA:  <br />POWERWALL 3 1707000-XX-Y <br />     (16) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA:  <br />POWERWALL 3 1707000-XX-Y <br />SYSTEM OCPD SIZE <br />(COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  <br />144 A X 1.25 =180 A → 200 A OVERCURRENT PROTECTION <br />GATEWAY SYSTEM AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = 200 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT  <br />FILL) [TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY) [TABLE 310.16] =  <br />0.91 X 1 X 225A = 204.75A <br />TERMINAL RATING[110.14(C)] = <br />3/0 AWG, 75°C RATED = 200A <br />200A < 204.75A   TERMINAL RATING GOVERNS CONDUCTOR SIZING <br />200A ≤ 200A   3/0 AWG AMPACITY OK <br />THEREFORE 3/0 AWG IS SUFFICIENT. <br />ALLOWABLE BACKFEED <br />ALLOWABLE BACKFEED = MAIN PANEL RATING = 225A <br />LOADS IN MAIN PANEL:0A LOADS + 200A GATEWAY BREAKER = 200A ≤ 225A <br />INTERCONNECTION MEETS CEC 705.12(B)(3)(3) REQUIREMENTS. <br />INVERTER INFORMATION <br />3200 W DC PHOTOVOLTAIC SYSTEM <br />     (8) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA:  <br />POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X  <br />(CONTINUOUS LOAD)[690.8(B)(1)]=  <br />14.88A X 1.25 X 1.25 = 23.25A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)  <br />[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG, 75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />23.25A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)  <br />[210.19(A)(1)] = 48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)  <br />[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = 6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 9 = 356.85 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.88 A X 1 = 18.6A <br />INVERTER INFORMATION <br />6400 W DC PHOTOVOLTAIC SYSTEM <br />     (16) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA:  <br />POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />14.88A X 1.25 X 1.25 = 23.25A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)  <br />[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />23.25A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)  <br />[210.19(A)(1)] =48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)  <br />[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = 6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 8 = 317.20 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.88 A X 2 = 37.2A <br />C <br />3340 S Crawford <br />Glen4/28/2025