Laserfiche WebLink
BACKUP LOADS <br />LOAD BREAKER RATING  <br />(AMPS)LABEL DEMAND  <br />LOAD <br />1 15A-1P BATHROOM LIGHTS 1500 W <br />2 20A-1P FAU 1 1500 W <br />3 20A-1P FAU 2 1500 W <br />4 20A-1P BATHROOM GFI 1500 W <br />5 20A-1P FRIDGE 1500 W <br />6 20A-1P MICROWAVE 1500 W <br />7 20A-1P DISPOSAL 1500 W <br />8 20A-1P DISHWASHER 1500 W <br />9 20A-1P KITCHEN LIGHTS 1500 W <br />10 20A-1P KITCHEN OUTLETS 1500 W <br />11 20A-1P DRYER 1500 W <br />12 20A-1P LIVING ROOM OUTLETS 1500 W <br />13 20A-1P LIVING ROOM LIGHTS 1500 W <br />14 20A-1P GFI OUTLETS 1500 W <br />15 20A-1P GFI OUTLETS 1500 W <br />16 20A-1P BEDROOM LIGHTS 1 1500 W <br />17 20A-1P BEDROOM LIGHTS 2 1500 W <br />18 20A-1P BEDROOM OUTLETS 1 1500 W <br />19 20A-1P BEDROOM OUTLETS 2 1500 W <br />20 50A-2P AC UNIT 1 6288 <br />21 50A-2P AC UNIT 2 6384 <br />22 50A-2P OVEN 9600 <br />23 50A-2P TESLA EV 9600 <br />24 30A-2P SPA 5760 <br />25 70A-2P SUB PANEL 13440 <br />SUB PANEL LOADS <br />26 15A-1P GARAGE 1500 W <br />27 15A-1P GARAGE FRIDGE 1500 W <br />28 15A-1P OFFICE LIGHTS 1500 W <br />29 15A-1P OFFICE OUTLETS 1500 W <br />30 15A-1P BATHROOM 2 LIGHTS 1500 W <br />31 15A-1P BATHROOM 2 OUTLETS 1500 W <br />32 15A-1P HALF BATH LIGHTS 1500 W <br />33 15A-1P LIVING ROOM LIGHTS 1500 W <br />34 15A-1P LIVING ROOM OUTLETS 1500 W <br />35 15A-1P HALF BATH GFI 1500 W <br />36 15A-1P BEDROOM LIGHTS 3 1500 W <br />37 15A-1P BEDROOM LIGHTS 4 1500 W <br />38 15A-1P BEDROOM OUTLETS 3 1500 W <br />39 15A-1P BEDROOM OUTLETS 4 1500 W <br />40 15A-1P OUTDOOR LIGHTS 1500 W PAGE <br />REV: C 4/8/2025 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />ANGELA SAMPSON <br />3340 S CRAWFORD GLEN,  <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br />  109R-340SAMP <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 642-8754 <br />APN: 412-521-03 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />BACKUP LOAD CALCS <br />ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE  <br />PANEL. <br />BACKED UP LOADS CALCULATION: <br />( 13440VA)/ 240V = 56 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. <br />THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 56A. <br />(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =  <br />56 A X 1.25 = 70A <br />BACKED UP LOADS PANEL BREAKER = 200A <br />70 A < 200A. <br />THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. <br />AC WIRE SIZING FOR BACKUP LOADS PANEL <br />MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />56 A X 1.25 = 70A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X 1 X 95A = 86.45A <br />TERMINAL RATING[110.14(C)] = <br />4 AWG, 75°C RATED = 85A <br />85A < 86.45A    TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />70A≤ 85A   4 AWG AMPACITY OK <br />THEREFORE 4 AWG IS SUFFICIENT. <br />  <br />   <br />PV-4.3 <br />BACKUP LOAD  <br />CALCS <br />C <br />C <br />3340 S Crawford <br />Glen4/28/2025