My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010 W Alco Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Alco Ave
>
2010 W Alco Ave Unit# 2
>
2010 W Alco Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:31 PM
Creation date
6/15/2025 12:44:01 PM
Metadata
Fields
Template:
Plan
Permit Number
101121972
Full Address
2010 W Alco Ave Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 7 <br /> <br />Geotechnical Parameters For Structural Design <br /> <br />For conservative purposes, the following “lowest” code values should be used for <br />structural design, as needed. <br /> <br />a. Allowable vertical bearing earth pressure: 1,500 psf. <br /> <br />An increase of one-third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br /> <br />b. Lateral bearing passive earth pressure: 100 psf. per foot into competent materials <br />below the finished ground surface. <br /> <br />An increase of one third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br /> <br />c. Lateral Sliding Resistance: cohesion = 130 psf. <br /> <br />The cohesion value is to be multiplied by the contact area. <br /> <br />In no case shall the lateral sliding resistance exceed one-half the dead load. <br /> <br />d. Soil unit weight: 120 pcf. <br /> <br />New Building Footings <br /> <br />In general, the foundation system for the proposed structure must be properly designed by <br />the civil/structural design engineer of record for this project and reviewed and approved <br />by the city prior to construction. <br /> <br />The adequacy for support of the proposed structure of the existing footings should be <br />evaluated by the civil/structural design engineer of record for this project. Underpinning <br />footings can be provided, if needed. <br /> <br />New building footings should be embedded minimum 24-inches below the adjacent <br />lowest finished grade. Minimum widths for isolated columns/pad footings, if any, should <br />be 24-inches, and for continuous wall footings should be 15-inches for one-story and 18- <br />inches for two story portions, if any. <br /> <br />Minimum reinforcement for new continuous footings should be two #5 re-bars at top and <br />two #5 re-bars at bottom. <br /> <br />Settlement <br /> <br />Distress to the existing house due to settlement of the underlying soils was not observed. <br />Therefore, deep-seated settlement of the soils underlying the site is not considered to be a <br />2010 W Alco Ave Unit <br />#24/22/2025