Laserfiche WebLink
TABLE 4.504.2 <br />SEALANT VOC LIMIT <br />LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER <br />SEALANTS VOC LIMIT <br />ARCHITECTURAL 250 <br />MARINE DECK 760 <br />NONMEMBRANE ROOF 300 <br />ROADWAY 250 <br />SINGLE-PLY ROOF MEMBRANE 450 <br />OTHER 420 <br />SEALANT PRIMERS <br />ARCHITECTURAL <br />- NONPOROUS <br />- POROUS <br />250 <br />775 <br />MODIFIED BITUMINOUS 500 <br />MARINE DECK 760 <br />OTHER 750 <br />TABLE 4.504.1 <br />ADHESIVE VOC LIMIT¹·² <br />LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER <br />ARCHITECTURAL APPLICATIONS VOC LIMIT <br />INDOOR CARPET ADHESIVES 50 <br />CARPET PAD ADHESIVES 50 <br />OUTDOOR CARPET ADHESIVES 150 <br />WOOD FLOORING ADHESIVES 100 <br />RUBBER FLOOR ADHESIVES 60 <br />SUBFLOOR ADHESIVES 50 <br />CERAMIC TILE ADHESIVES 65 <br />VCT AND ASPHALT TILE ADHESIVES 50 <br />DRYWALL AND PANEL ADHESIVES 50 <br />COVE BASE ADHESIVES 50 <br />MULTIPURPOSE CONSTRUCTION ADHESIVES 70 <br />STRUCTURAL GLAZING ADHESIVES 100 <br />SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 <br />OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 <br />SPECIALTY APPLICATIONS <br />PVC WELDING 510 <br />CPVC WELDING 490 <br />ABS WELDING 325 <br />PLASTIC CEMENT WELDING 250 <br />ADHESIVE PRIMER FOR PLASTIC 550 <br />CONTACT ADHESIVE 80 <br />SPECIAL PURPOSE CONTACT ADHESIVE 250 <br />STRUCTURAL WOOD MEMBER ADHESIVE 140 <br />TOP AND TRIM ADHESIVE 250 <br />SUBSTRATE SPECIFIC APPLICATIONS <br />METAL TO METAL 30 <br />PLASTIC FOAMS 50 <br />POROUS MATERIAL (EXCEPT WOOD)50 <br />WOOD 30 <br />FIBERGLASS 80 <br />TABLE 4.504.3 <br />VOC CONTENT LIMITS FOR ACHITECTURAL COATINGS²'³ <br />GRAMS OF VOC PER LITER OF COATING <br />LESS WATER AND LESS EXEMPT COMPOUNDS <br />COATING CATEGORY VOC LIMIT <br />FLAT COATINGS 50 <br />NONFLAT COATINGS 100 <br />NONFLAT-HIGH GLOSS COATINGS 150 <br />SPECIALTY COATINGS <br />ALUMINUM ROOF COATINGS 400 <br />BASEMENT SPECIALTY COATINGS 400 <br />BITUMINOUS ROOF COATINGS 50 <br />BITUMINOUS ROOF PRIMERS 350 <br />BOND BREAKERS 350 <br />CONCRETE CURING COMPOUNDS 350 <br />CONCRETE / MASONRY SEALERS 100 <br />DRIVEWAY SEALERS 50 <br />DRY FOG COATINGS 150 <br />FAUX FINISHING COATINGS 350 <br />FIRE RESISTIVE COATINGS 350 <br />FLOOR COATINGS 100 <br />FORM-RELEASE COMPOUNDS 250 <br />GRAPHIC ARTS COATINGS (SIGN PAINTS)500 <br />HIGH TEMPERATURE COATINGS 420 <br />INDUSTRIAL MAINTENANCE COATINGS 250 <br />LOW SOLIDS COATINGS¹120 <br />MAGNESITE CEMENT COATINGS 450 <br />MASTIC TEXTURE COATINGS 100 <br />METALLIC PIGMENTED COATINGS 500 <br />MULITCOLOR COATINGS 250 <br />PRETREATMENT WASH PRIMERS 420 <br />PRIMERS, SEALERS, AND UNDERCOATERS 100 <br />REACTIVE PENETRATING SEALERS 350 <br />RECYCLED COATINGS 250 <br />ROOF COATINGS 50 <br />RUST PREVENTIVE COATINGS 250 <br />SHELLACS <br />- CLEAR <br />- OPAQUE <br />730 <br />550 <br />SPECIALTY PRIMERS, SEALERS, AND <br />UNDERCOATERS 100 <br />STAINS 250 <br />STONE CONSOLIDANTS 450 <br />SWIMMING POOL COATINGS 340 <br />TRAFFIC MARKING COATINGS 100 <br />TUB AND TILE REFINISH COATINGS 420 <br />WATERPROOFING MEMBRANES 250 <br />WOOD COATINGS 275 <br />WOOD PRESERVATIVES 350 <br />ZINC-RICH PRIMERS 340 <br />TABLE 4.504.5 <br />FORMALDEHYDE LIMITS¹ <br />MAXIMUM FORMALDEHYDE EMISSISIONS IN PARTS PER MILLION <br />PRODUCT CURRENT LIMIT <br />HARDWOOD PLYWOOD VENEER CORE 0.05 <br />HARDWOOD PLYWOOD COMPOSITE CORE 0.05 <br />PARTICLEBOARD 0.09 <br />MEDIUM DENSITY FIBERBOARD 0.11 <br />THIN MEDIUM DENSITY FIBERBOARD²0.13 <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />CHAPTER 4 - RESIDENTIAL MANDATORY MEASURES CHECKLIST <br />SECTION HEADING REQUIREMENTS SHEET <br />REFERENCE <br />DIVISION 4.1 - PLANNING AND DESIGN (SITE DEVELOPMENT) <br />4.106.2 <br />STORM WATER <br />DRAINAGE AND <br />RETENTION <br />DURING <br />CONSTRUCTION <br />PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL AND ARE <br />NOT PART OF A LARGER COMMON PLAN OF DEVELOPMENT WHICH IN <br />TOTAL DISTURBS ONE ACRE OR MORE, SHALL MANAGE STORM <br />WATER DRAINAGE DURING CONSTRUCTION. <br />4.106.3 GRADING AND <br />PAVING <br />SITE GRADING OR DRAINAGE SYSTEM WILL MANAGE ALL SURFACE <br />WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. <br />DIVISION 4.1 - ELECTRICAL VEHICLE CHARGING FOR NEW CONSTRUCTION (SITE DEVELOPMENT) <br />4.106.4 <br />ELECTRIC <br />VEHICLE (EV) <br />CHARGING FOR <br />NEW <br />CONSTRUCTION <br />NEW CONSTRUCTION SHALL COMPLY WITH SECTION 4.106.4.1 OR <br />4.106.4.2 TO FACILITATE FUTURE INSTALLATION AND USE OF EV <br />CHARGERS. ELECTRICAL VEHICLE SUPPLY EQUIPMENT (EVSE) <br />SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA <br />ELECTRICAL CODE, ARTICLE 625. <br />4.106.4.1 <br />NEW ONE- AND <br />TWO-FAMILY <br />DWELLINGS AND <br />TOWNHOUSES <br />WITH ATTACHED <br />GARAGES <br />FOR EACH DWELLING UNIT INSTALL A MIN. 1" DIAMETER LISTED <br />RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH <br />CIRCUIT. THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE <br />PANEL AND TERMINATE INTO A LISTED CABINET, BOX OR <br />ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF <br />AN EV CHARGER. THE SERVICE PANEL SHALL PROVIDE CAPACITY TO <br />INSTALL A 40-AMPERE MIN. DEDICATED BRANCH CIRCUIT AND <br />SPACE(S) RESERVED TO PERMIT A BRANCH CIRCUIT OVERCURRENT <br />PROTECTIVE DEVICE. <br />4.106.4.2 <br />NEW <br />MULTIFAMILY <br />DWELLINGS <br />IF RESIDENTIAL PARKING IS AVAILABLE, TEN (10) PERCENT OF THE <br />TOTAL NUMBER OF PARKING SPACES ON A BUILDING SITE, <br />PROVIDED FOR ALL TYPES OF PARKING FACILITIES, SHALL BE <br />ELECTRIC VEHICLE CHARGIND SPACES (EV SPACES) CAPABLE OF <br />SUPPORTING FUTURE EVSE. CALCULATIONS FOR THE REQUIRED <br />NUMBER OF EV SPACES SHALL BE ROUNDED UP TO THE NEAREST <br />WHOLE NUMBER. <br />NOTE: CONSTRUCTION DOCUMENTS ARE INTENDED TO <br />DEMONSTRATE THE PROJECT'S CAPABILITY AND CAPACITY FOR <br />FACILITATING FUTURE EV CHARGING. THERE IS NO REQUIREMENT <br />FOR EV SPACES TO BE CONSTRUCTED OR AVAILABLE UNTIL EV <br />CHARGERS ARE INSTALLED FOR USE. <br />4.106.4.2.1 & <br />4.106.4.2.1.1 <br />ELECTRIC <br />VEHICLE <br />CHARGING <br />SPACE (EV <br />SPACE) <br />LOCATIONS <br />CONSTRUCTION DOCUMENTS SHALL INDICATE THE LOCATION OF <br />PROPOSED EV SPACES. WHERE COMMON USE PARKING IS <br />PROVIDED AT LEAST ONE EV SPACE SHALL BE LOCATED IN COMMON <br />USE AREA AND AVAILABLE FOR USE BY ALL RESIDENTS. <br />WHEN EV CHARGERS ARE INSTALLED, EV SPACES REQUIRED BY <br />4.106.2.2, ITEM 3, SHALL COMPLY WITH AT LEAST ONE OF THE <br />FOLLOWING OPTIONS: <br />1 - THE EV SPACE SHALL BE LOCATED ADJACENT TO AN ACCESSIBLE <br />PARKING SPACE COMPLYING WITH CBC, CHAPTER 11A TO ALLOW <br />USE OF THE EV CHARGER FROM THE ACCESSIBLE PARKING SPACE. <br />2 - THE EV SPACE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO <br />THE BUILDING AS DEFINED BY CBC CHAPTER 2. <br />EXCEPTION: ELECTRIC VEHICLE CHARGING STATIONS DESIGNED <br />AND CONSTRUCTED IN COMPLIANCE WITH THE CALIFORNIA <br />BUILDING CODE, CHAPTER 11B, ARE NOT REQUIRED TO COMPLY <br />WITH SECTION 4.106.4.2.1.1 AND SECTION 4.106.4.2.2, ITEM 3. <br />4.106.4.2.2.1.2 <br />ELECTRIC <br />VEHICLE <br />CHARGING <br />SPACE (EV <br />SPACE) <br />DIMENSIONS AND <br />SLOPE <br />THE EV SPACE SHALL COMPLY WITH THE FOLLOWING: <br />1 - THE MIN. LENGTH SHALL BE 18 FEET. <br />2 - THE MIN. WIDTH SHALL BE 9 FEET. <br />3 - ONE IN EVERY 25 EV SPACE, BUT NOT LESS THAN ONE EV SPACE <br />SHALL ALSO HAVE AN 8-FOOT WIDE MIN. AISLE. A 5-FOOT WIDE MIN. <br />AISLE SHALL BE PERMITTED PROVIDED THE WIDTH OF EV SPACE IS <br />12 FEET. <br />a. SURFACE SLOPE FOR THIS EV SPACE AND THE AISLE SHALL NOT <br />EXCEED 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2.083 PERCENT) <br />IN ANY DIRECTION. <br />4.106.4.2.3 <br />SINGLE EV <br />SPACE <br />REQUIRED <br />INSTALL A LISTED RACEWAY CAPABLE OF ACCOMMODATING A <br />208/240-VOLT DEDICATED BRANCH CIRCUIT. THE RACEWAY SHALL <br />NOT BE LESS THAN TRADE SIZE 1 (NOMINAL 1-INCH INSIDE <br />DIAMETER). THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE <br />OR SUBPANEL AND SHALL TERMINATE INTO A LISTED CABINET, BOX <br />OR ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION <br />OF THE EV SPACE. CONSTRUCTION DOCUMENTS SHALL IDENTIFY <br />THE RACEWAY TERMINATION POINT. THE SERVICE PANEL AND/OR <br />SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE <br />MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO <br />PERMIT INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT <br />PROTECTIVE DEVICE. <br />4.106.4.2.3 <br />MULTIPLE EV <br />SPACES <br />REQUIRED <br />CONSTRUCTION DOCUMENTS SHALL INDICATE THE RACEWAY <br />TERMINATION POINT AND PROPOSED LOCATION OF FUTURE EV <br />SPACE AND EV CHARGERS. CONSTRUCTION DOCUMENTS SHALL <br />ALSO PROVIDE INFORMATION ON AMPERAGE OF FUTURE EVSE, <br />RACEWAY METHOD(S), WIRING SCHEMATICS AND ELECTRICAL LOAD <br />CALCULATIONS TO VERIFY THAT THE ELECTRICAL PANEL SERVICE <br />CAPACITY AND ELECTRICAL SYSTEM, INCLUDING ANY ON-SITE <br />DISTRIBUTION TRANSFORMER(S), HAVE SUFFICIENT CAPACITY TO <br />SIMULTANEOUSLY CHARGE ALL EVs AT ALL REQUIRED EV SPACE AT <br />THE FULL RATED AMPERAGE OF THE EVSE. PLAN DESIGN SHALL BE <br />BASED UPON A 40-AMPERE MINIMUM BRANCH CIRCUIT. RACEWAYS <br />AND RELATED COMPONENTS THAT ARE PLANNED TO BE INSTALLED <br />UNDERGROUND, ENCLOSED, INACCESSIBLE OR IN CONCEALED <br />AREAS AND SPACES SHALL BE INSTALLED AT THE TIME OF ORIGINAL <br />CONSTRUCTION. <br />4.106.4.2.4 IDENTIFICATION <br />THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL <br />IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE <br />SPACE(S) RESERVED FOR FUTURE EV CHARGING PURPOSES AS “EV <br />CAPABLE” IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL <br />CODE. <br />4.106.4.2.5 <br />ELECTRIC <br />VEHICLE READY <br />SPACE SIGNAGE <br />ELECTRIC VEHICLE READY SPACES SHALL BE IDENTIFIED BY <br />SIGNAGE OR PAVEMENT MARKINGS, IN COMPLIANCE WITH <br />CALTRANS TRAFFIC OPERATIONS POLICY DIRECTIVE 13-01(ZERO <br />EMISSION VEHICLE SIGNS AND PAVEMENT MARKINGS) OR ITS <br />SUCCESSOR(S). <br />DIVISION 4.2 - ENERGY EFFICIENCY <br />4.201.1 SCOPE <br />FOR THE PURPOSES OF MANDATORY ENERGY EFFICIENCY <br />STANDARDS IN THIS CODE, THE CALIFORNIA ENERGY COMMISSION <br />WILL CONTINUE TO ADOPT MANDATORY STANDARDS. <br />DIVISION 4.3 - WATER EFFICIENCY AND CONSERVATION (INDOOR WATER USE) <br />4.303.1 <br />WATER <br />CONSERVING <br />PLUMBING <br />FIXTURES AND <br />FITTING <br />PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE <br />FOLLOWING: <br />TOILETS < 1.28 GAL/FLUSH <br />URINALS < .5 GAL/FLUSH <br />SHOWERHEADS < 1.8 GPM @ 80 PSI <br />MULTIPLE SHOWER HEADS COMBINED FLOW RATE OF ALL SHOWER <br />HEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A <br />SINGLE VALVE < 1.8 GPM @ 80 PSI OR DESIGNED TO ALLOW ONLY <br />ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. <br />LAVATORY FAUCETS 0.8 GPM @ 20PSI < X < 1.2 GPM @ 60 PSI <br />LAVATORY FAUCETS IN COMMON AND PUBLIC USE AREAS < .5 GPM <br />@ 60 PSI <br />METERING FAUCETS < .20 GPM PER CYCLE <br />KITCHEN FAUCETS < 1.8 GPM @ 60 PSI - MAY TEMPORARILY <br />INCREASE TO 2.2 GPM AND MUST DEFAULT TO 1.8 GPM <br />4.303.3 <br />STANDARDS FOR <br />PLUMBING <br />FIXTURES AND <br />FITTINGS <br />PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE AND SHALL <br />MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1701.1 <br />OF THE CALIFORNIA PLUMBING CODE. <br />DIVISION 4.3 - WATER EFFICIENCY AND CONSERVATION (OUTDOOR WATER USE) <br />4.304.1 <br />OUTDOOR <br />POTABLE WATER <br />USE IN <br />LANDSCAPE <br />AREAS <br />AFTER DECEMBER 1, 2018, NEW RESIDENTIAL DEVELOPMENTS WITH <br />AN AGGREGATE LANDSCAPE AREA EQUAL TO OR GREATER THAN <br />500 SQUARE FEET SHALL COMPLY WITH ONE OF THE FOLLOWING <br />OPTIONS: <br />1 - A LOCAL WATER EFFICIENT LANDSCAPE ORDINANCE OR THE <br />CURRENT CALIFORNIA DEPARTMENT OF WATER RESOURCES' <br />MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO), <br />WHICHEVER IS MORE STRINGENT; OR <br />2 - PROJECTS WITH AGGREGATE LANDSCAPE AREAS LESS THAN <br />2,500 SQUARE FEET MAY COMPLY WITH THE MWELO'S APPENDIX D <br />PRESCRIPTIVE COMPLIANCE OPTION. <br />DIVISION 4.4 - MATERIAL CONSERVATION & RESOURCE EFFICIENCY (ENHANCED DURABILITY & REDUCED <br />MAINTENANCE) <br />4.406.1 RODENT <br />PROOFING <br />ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS <br />OR OTHER OPENINGS IN SOLE/BOTTOM PLATES IN EXTERIOR WALLS <br />SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY <br />CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE <br />MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING <br />AGENCY. <br />DIVISION 4.4 - MATERIAL CONSERVATION & RESOURCE EFFICIENCY (CONSTRUCTION WASTE REDUCTION, <br />DISPOSAL & RECYCLING) <br />4.408.1 <br />CONSTRUCTION <br />WASTE <br />REDUCTION <br />RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE <br />NON-HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS, OR <br />MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION <br />WASTE MANAGEMENT ORDINANCE. EXCEPTIONS: <br />1 - EXCAVATED SOIL AND LAND-CLEARING DEBRIS. <br />2 - ALTERNATIVE WASTE REDUCTION METHODS DEVELOPED BY <br />WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLED <br />FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT EXIST <br />OR ARE NOT LOCATED REASONABLY CLOSE TO THE JOBSITE. <br />3 - THE ENFORCING AGENCY MAY MAKE EXCEPTIONS TO THE <br />REQUIREMENTS OF THIS SECTION WHEN ISOLATED JOB SITES ARE <br />LOCATED IN AREAS BEYOND THE HAUL BOUNDARIES OF THE <br />DIVERSION FACILITY <br />4.408.2 <br />CONSTRUCTION <br />WASTE <br />MANAGEMENT <br />PLAN <br />SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN IN <br />CONFORMANCE WITH ITEMS 1 THROUGH 5 OF SECTION 4.408.2. <br />4.408.3 <br />WASTE <br />MANAGEMENT <br />COMPANY <br />UTILIZE A WASTE MANAGEMENT COMPANY APPROVED BY THE <br />ENFORCING AGENCY WHICH CAN PROVIDE VERIFIABLE <br />DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND <br />DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL <br />COMPLIES WITH SECTION 4.408.1 <br />4.408.4 & <br />4.408.4.1 <br />WASTE STREAM <br />REDUCTION <br />ALTERNATIVE <br />PROJECTS THAT GENERATE A TOTAL COMBINED WEIGHT OF <br />CONSTRUCTION AND DEMOLITION WASTE DISPOSED OF IN <br />LANDFILLS, WHICH DO NOT EXCEED 3.4 LBS/S.F. (LOW RISE) OR 2 <br />LBS/S.F. (HIGH RISE) OF THE BUILDING AREA SHALL MEET THE <br />MINIMUM 65% CONSTRUCTION WASTE REDUCTION REQUIREMENT IN <br />SECTION 4.408.1 <br />4.408.5 DOCUMENTATION <br />DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY <br />WHICH DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS 1 <br />THROUGH 5, SECTION 4.408.3 OR SECTION 4.408.4. <br />DIVISION 4.4 - MATERIAL CONSERVATION & RESOURCE EFFICIENCY (BUILDING MAINTENANCE & OPERATION) <br />4.410.1 <br />OPERATION AND <br />MAINTENANCE <br />MANUAL <br />AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DISC, <br />WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE <br />ENFORCING AGENCY WHICH COVERS ITEMS 1 THROUGH 10 OF <br />SECTION 4.410.1 SHALL BE PLACED IN THE BUILDING. <br />4.410.2 RECYCLING BY <br />OCCUPANTS <br />WHERE 5 OR MORE MULTI-FAMILY DWELLING UNITS ARE <br />CONSTRUCTED ON A BUILDING SITE, PROVIDE READILY ACCESSIBLE <br />AREA(S) THAT SERVES ALL BUILDINGS ON THE SITE AND IS <br />IDENTIFIED FOR THE DEPOSITING, STORAGE, AND COLLECTION OF <br />NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (AT A <br />MINIMUM) PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS, <br />ORGANIC WASTE, AND METALS, OR MEET A LAWFUL ENACTED LOCAL <br />RECYCLING ORDINANCE, IF MORE RESTRICTIVE. <br />EXCEPTION: RURAL JURISDICTIONS THAT MEET AND APPLY FOR <br />THE EXEMPTION IN PUBLIC RESOURCES CODE SECTION <br />42649.82(a)(2)(A) ET SEQ. ARE NOT REQUIRED TO COMPLY WITH THE <br />ORGANIC WASTE PORTION OF THIS SECTION. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY (FIREPLACES) <br />4.503.1 GENERAL <br />ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENTED <br />SEALED-COMBUSTION TYPE. ANY INSTALLED WOOD STOVE OR <br />PELLET STOVE SHALL COMPLY WITH U.S. EPA NEW SOURCE <br />PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS AS <br />APPLICABLE, AND SHALL HAVE A PERMANENT LABEL INDICATING <br />THEY ARE CERTIFIED TO MEET THE EMISSION LIMITS. WOOD <br />STOVES, PELLET STOVES AND FIREPLACES SHALL ALSO COMPLY <br />WITH LOCAL ORDINANCES. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY (POLLUTANT CONTROL) <br />CA RESIDENTIAL <br />MANDATORY <br />MEASURES <br />A0-41 <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />1606 N Mabury St <br />4/28/2025