4.504.1 <br />COVERING OF <br />DUCT OPENINGS <br />AND PROTECTION <br />OF MECHANICAL <br />EQUIPMENT <br />DURING <br />CONSTRUCTION <br />AT THE TIME OF ROUGH INSTALLATION, DURING STORAGE ON THE <br />CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING <br />AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR <br />DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED BY <br />METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE <br />THE AMOUNT OF WATER, DUST AND DEBRIS WHICH MAY ENTER THE <br />SYSTEM. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY (POLLUTANT CONTROL) CONTINUED <br />4.504.2.1 <br />ADHESIVES, <br />SEALANTS AND <br />CAULKS <br />ADHESIVES, SEALANTS AND CAULKS USED ON THE PROJECT SHALL <br />MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS UNLESS <br />MORE STRINGENT LOCAL OR REGIONAL AIR POLLUTION OR AIR <br />QUALITY MANAGEMENT DISTRICT RULES APPLY: <br />1 - ADHESIVES, ADHESIVES BONDING PRIMERS, ADHESIVE PRIMERS, <br />SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH <br />LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY <br />MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD <br />RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 4.504.1 OR 4.504.2 AS <br />APPLICABLE. SUCH PRODUCTS SHALL ALSO COMPLY WITH RULE <br />1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS <br />(CHLOROFORM, ETHYLENE, DICHLORIDE, METHYLENE CHLORIDE, <br />PERCHLORETHYLENE, AND TRICHLOROETHLENE), EXCEPT FOR <br />AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2 BELOW. <br />2 - AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, <br />AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF <br />PRODUCTION, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN <br />ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID <br />OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND <br />OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF <br />CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE REGULATIONS, <br />TITLE 17, COMMENCING WITH SECTION 94507. <br />4.504.2.2 PAINTS AND <br />COATINGS <br />ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC <br />LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL SUGGESTED <br />CONTROL MEASURES AS SHOWN IN TABLE 4.504.3 UNLESS THE <br />MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT <br />FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE <br />SPECIALTY COATINGS LISTED IN TABLE 4.504.3, SHALL BE <br />DETERMINED BY CLASSIFYING THE COATS AS FLAT, NONFLAT, OR <br />NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED <br />IN SUBSECTIONS 4.21, 4.36, AND 4.37, OF THE 2007 CALIFORNIA AIR <br />RESOURCES BOARD, SUGGESTED CONTROL MEASURE, AND THE <br />CORRESPONDING FLAT, NONFLAT, OR NONFLAT-HIGH GLOSS VOC <br />LIMIT IN 4.504.3 SHALL APPLY. <br />4.504.2.3 AEROSOL PAINTS <br />AND COATINGS <br />AEROSOL PAINTS AND COATINGS SHALL MEET THE <br />PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(a)(2) <br />AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF <br />CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, <br />IN SECTION 94522(e)(1) AND (f)(1) OF CALIFORNIA CODE OF <br />REGULATIONS, TITLE 17 COMMENCING WITH SECTION 94520; AND IN <br />AREAS UNDER THE JURISDICTION OF THE BAY AREA AIR QUALITY <br />MANAGEMENT DISTRICT ADDITIONALLY COMPLY WITH THE PERCENT <br />VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8 RULE 49. <br />4.504.2.4 VERIFICATION <br />VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE <br />PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. <br />DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO THE <br />FOLLOWING: <br />1- MANUFACTURER'S PRODUCT SPECIFICATIONS <br />2 - FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS <br />A4.504.3 CARPET <br />SYSTEMS <br />ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE <br />TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE <br />FOLLOWING: 1 - <br />CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM <br />2 - CALIFORNIA DEPARTMENT OF PUBLIC HEALTH "STANDARD <br />METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC <br />CHEMICAL EMISSIONS FROM INDOOR SOURCES USING <br />ENVIRONMENT CHAMBERS" VERSION 1.1, FEBRUARY 2010 (ALSO <br />KNOWN AS SPECIFICATION 01350). <br />3 - NSF/ANSI 140 AT THE GOLD LEVEL <br />4 - SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE <br />GOLD <br />4.504.3.1 CARPET <br />CUSHION <br />ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL <br />MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE'S <br />GREEN LABEL PROGRAM. <br />4.504.3.2 CARPET <br />ADHESIVE <br />ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE <br />4.504.1. <br />4.504.4 <br />RESILIENT <br />FLOORING <br />SYSTEMS <br />WHERE RESILIENT FLOORING IS INSTALLED AT LEAST 80% OF FLOOR <br />AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE <br />OR MORE OF THE FOLLOWING: <br />1 - PRODUCTS COMPLIANT WITH THE CALIFORNIA DEPT. OF PUBLI <br />HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION <br />OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR <br />SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.1, <br />FEBRUARY 2010 (AKA SPECIFICATION 01350), CERTIFIED AS A CHPS <br />LOW-EMITTING MATERIAL IN THE COLLABORATIVE FOR HIGH <br />PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCTS <br />DATABASE. <br />2 - PRODUCTS CERTIFIED UNDER UL GREENGUARD (FORMERLY THE <br />GREENGUARD CHILDREN & SCHOOLS PROGRAM). <br />3 - CERTIFICATION UNDER THE RESILIENT FLOOR COVERING <br />INSTITUTE (RFCI) FLOOR SCORE PROGRAM. <br />4 - MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH <br />"STANDARD METHOD FOR THE TESTING AND EVALUATION OF <br />VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES <br />USING ENVIRONMENT CHAMBERS" VERSION 1.1, FEBRUARY 2010 <br />(ALSO KNOWN AS SPECIFICATION 01350). <br />4.504.5 <br />COMPOSITE <br />WOOD <br />PRODUCTS <br />HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY <br />FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR <br />OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS <br />FOR FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXICS CONTROL <br />MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ETSEQ.), BY OR <br />BEFORE THE DATES SPECIFIED IN THOSE SECTIONS AS SHOWN IN <br />TABLE 4.504.5. <br />4.504.5.1 DOCUMENTATION <br />VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE <br />PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. <br />DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE <br />FOLLOWING: <br />1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. <br />2. CHAIN OF CUSTODY CERTIFICATIONS. <br />3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE <br />WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, <br />ET SEQ.). <br />4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR <br />PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE <br />AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S, AND CANADIAN CSA <br />O121, CSA O151, CSA O153, AND CSA O325 STANDARDS. <br />5. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY (INTERIOR MOISTURE CONTROL) <br />4.505.2 CONCRETE SLAB <br />FOUNDATIONS <br />CONCRETE SLAB FOUNDATIONS REQUIRED TO HAVE A VAPOR <br />RETARDER BY CALIFORNIA BUILDING CODE, CCR, TITLE 24, CHAPTER <br />19 OR CONCRETE SLAB-ON-GROUND FLOORS REQUIRED TO HAVE A <br />VAPOR RETARDER BY THE CALIFORNIA RESIDENTIAL CODE, <br />CHAPTER 5 SHALL COMPLY WITH THIS SECTION. <br />4.505.2.1 CAPILLARY <br />BREAK <br />A CAPILLARY BREAK SHALL BE INSTALLED IN COMPLIANCE WITH AT <br />LEAST ONE OF THE FOLLOWING: <br />1 - A 4 INCH (101.6MM) THICK BASE OF 1/2 INCH (12.7MM) OR LARGER <br />CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER <br />IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN <br />WHICH WILL ADDRESS BLEEDING, SHRINKAGE AND CURLING SHALL <br />BE USED. SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. <br />2 - OTHER EQUIVALENT METHODS APPROVED BY THE ENFORCING <br />AGENCY. 3 - A SLAB DESIGN SPECIFIED BY A <br />LICENSED DESIGN PROFESSIONAL. <br />4.505.3 <br />MOISTURE <br />CONTENT OF <br />BUILDING <br />MATERIAL <br />BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE <br />SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT <br />BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19% <br />MOISTURE CONTENT. MOISTURE CONTENT SHALL BE VERIFIED IN <br />COMPLIANCE WITH ONE OF THE FOLLOWING: <br />1 - MOISTURE CONTENT SHALL BE DETERMINED WITH EITHER A <br />PROBE-TYPE OR A CONTACT-TYPE MOISTURE METER. <br />2 - MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET TO 4 <br />FEET FROM THE GRADE STAMPED END OF EACH PIECE TO BE <br />VERIFIED. 3 - AT <br />LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED <br />ON WALL AND FLOOR FRAMING WITH DOCUMENTATION ACCEPTABLE <br />TO THE ENFORCING AGENCY PROVIDED AT THE TIME OF APPROVAL <br />TO ENCLOSE THE WALL AND FLOOR FRAMING. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY ( INDOOR AIR QUALITY & EXHAUST) <br />4.506.1 BATHROOM <br />EXHAUST FAN <br />EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL <br />COMPLY WITH THE FOLLOWING: <br />1 - FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO <br />TERMINATE OUTSIDE THE BUILDING. <br />2 - UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE <br />VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY <br />CONTROL <br />a) HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTING <br />BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT. A <br />HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF <br />ADJUSTMENT. <br />b) A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE <br />EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL (I.E. BUILT-IN) <br />NOTE: <br />1)FOR THE PURPOSE OF THIS SECTION A BATHROOM IS A ROOM <br />WHICH CONTAINS A BATHTUB, SHOWER, OR TUB/SHOWER <br />COMBINATION. <br />2) LIGHTING INTEGRAL TO BATHROOM EXHAUST FANS SHALL <br />COMPLY WITH THE CALIFORNIA ENERGY CODE. <br />DIVISION 4.5 - ENVIRONMENTAL QUALITY ( ENVIRONMENTAL COMFORT) <br />4.507.2 <br />HEATING AND AIR <br />CONDITIONING <br />SYSTEM DESIGN <br />HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED, <br />DESIGNED, AND HAVE THEIR EQUIPMENT SELECTED USING THE <br />FOLLOWING METHODS: <br />1 - THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO <br />ANSI/ACCA 2 MANUAL J - 2011 (RESIDENTIAL LOAD CALCULATION), <br />ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE <br />OR METHODS. <br />2 - DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL <br />D-2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR <br />OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. <br />3 - SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO <br />ANSI/ACCA 3 MANUAL S - 2014 (RESIDENTIAL EQUIPMENT <br />SELECTION), OR OTHER EQUIVALENT DESIGN SOFTWARE OR <br />METHODS. <br />EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES <br />NECESSARY TO ENSURE THE SYSTEMS FUNCTION ARE <br />ACCEPTABLE. <br />CHAPTER 7 - INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS (QUALIFICATIONS) <br />702.1 INSTALLER <br />TRAINING [HCD] <br />HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN <br />THE PROPER INSTALLATION OF HVAC SYSTEMS INCLUDING DUCTS <br />AND EQUIPMENT BY A NATIONALLY OR REGIONALLY RECOGNIZED <br />TRAINING OR CERTIFICATION PROGRAM. EXAMPLES OF <br />ACCEPTABLE HVAC TRAINING AND CERTIFICATION PROGRAMS <br />INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: <br />1 - STATE CERTIFIED APPRENTICESHIP PROGRAMS. <br />2 - PUBLIC UTILITY TRAINING PROGRAMS. <br />3 - TRAINING PROGRAMS SPONSORED BY TRADE, LABOR OR <br />STATEWIDE ENERGY OR VERIFICATION ORGANIZATIONS. <br />4 - PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS. <br />5 - OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. <br />702.2 SPECIAL <br />INSPECTION <br />WHEN REQUIRED BY THE ENFORCING AGENCY, SPECIAL <br />INSPECTORS WILL PROVIDE INSPECTIONS OR OTHER DUTIES <br />NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. <br />SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE FOR THE <br />PARTICULAR TYPE OF INSPECTION OR TASK, <br />DIVISION 7.3 - VERIFICATIONS <br />703.1 DOCUMENTATION <br />DOCUMENTATION USED TO SHOW COMPLIANCE SHALL INCLUDE BUT <br />IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, <br />SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, <br />INSPECTION REPORTS OR OTHER METHODS ACCEPTABLE TO THE <br />ENFORCING AGENCY.. <br />CA RESIDENTIAL <br />MANDATORY <br />MEASURES <br />A0-42 <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />1606 N Mabury St <br />4/28/2025