Laserfiche WebLink
306 <br />8 <br />266 <br />8 <br />BATH <br />8 0 CLG. <br />266 <br />8 <br />26 <br />3 <br />0 <br /> <br />S <br />L <br />KITCHEN <br />8 0 CLG. <br />LIVING <br />8 0 CLG. <br />20'-0" <br />SUB-PANEL <br />TANKLESS <br />WATER HEATER AC CONDENSER <br />A <br />1 <br />2 <br />3 <br />4 <br />5 <br />166 <br />86 <br />1 <br />2 <br />4 <br />3 <br />7 5 <br />6 <br />2,460 SQ. IN. <br />1' <br />- <br />3 <br />" <br />1' <br />- <br />3 <br />" <br />2'-9" <br />10'-11 1/2"3'-3 1/2"5'-9" <br />20 <br />' <br />- <br />1 <br />" <br />9' <br />- <br />7 <br />" <br />7' <br />- <br />1 <br />1 <br />" <br />2' <br />- <br />7 <br />" <br />3' <br />- <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />5'-3 1/2" <br />6'-5"2'-3 1/2" <br />1' <br />- <br />7 <br />" <br />1' <br />- <br />0 <br />" <br />1'-3 1/2" <br />1'-8" <br />1'-9 1/2" <br />3' <br />- <br />7 <br />" <br />4' <br />- <br />4 <br /> <br />1 <br />/ <br />4 <br />" <br />22 <br />-- <br />3 <br />3 <br />- <br />- <br />SQUARE FOOTAGE <br />ADU 402 SQ. FT. <br />TYPICAL EXTERIOR WALL <br />SYSTEM: R-15 <br />2X4 OR 2X6 STUDS AT 16" <br />O.C. (PER PLAN) WITH 1/2" <br />DRYWALL OVER. <br />R-30 + R-15 ROOF ATTIC INSULATION <br />LIVING <br />8' <br />- <br />1 <br />" <br />T.O.PL. <br />F.FL. <br />LIVING KITCHEN 8' <br />- <br />1 <br />" <br />6' <br />- <br />8 <br />" <br />T.O.PL. <br />F.FL. <br />HEADER HT. <br />13 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />BUILDING HEIGHT <br />KEYNOTES <br />DOUBLE SINK WITH GARBAGE DISPOSAL <br />DISHWASHER ( 24" WIDE X 24" DEEP W/ AIR GAP) VERIFY DIMENSIONS WITH <br />MANUFACTURER. <br />30" CLEAR REFRIGERATOR SPACE (PROVIDE RECESSED COLD WATER BIB AND <br />SHUT-OFF FOR ICE-MAKER ) W/ PRE-PLUMB REVERSE OSMOSIS <br />30" GAS SLIDE-IN w/ LIGHT AND FAN AND MICROWAVE ABOVE. <br />SHOWER PAN WITH 6'-0" ( MIN. ) TILE SURROUND OVER 'HARDI-BACKER' OR <br />APPROVED EQUAL BOARD W/ TEMPERED GLASS SHOWER ENCLOSURE. CONTROL <br />VALVES TO BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES PER <br />THE CPC <br />30" X 30" ATTIC ACCESS MIN. WITH 30" MIN CLEAR HEADROOM PROVIDED FAU MAY <br />PASS THROUGH PER THE CRC. PROVIDE SWITCH LIGHT, 110 V OUTLET AND 24" <br />PLATFORM TO FAU. PROVIDE A VINYL FOAM WEATHER-SEAL TO COMPLY W/ IECC <br />STACKED WASHER & DRYER SPACE WITH SMITTY PAN. PROVIDE RECESSED <br />WATER CONNECTIONS & DRYER VENT TO OUTSIDE AIR PER C.M.C. SECTION <br />504.3.2. CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE 4 INCHES IN <br />DIAMETER AND 14' MAXIMUM LENGTH WITH 2 ELBOWS, UNLESS CALCULATIONS <br />ARE PROVIDED. THE DUCT LENGTH SHALL BE REDUCED BY 2 FT FOR EVERY <br />ELBOW IN EXCESS OF TWO. SEE MECHANICAL DRAWINGS FOR VENTS EXCEEDING <br />14' IN LENGTH. <br />NOTES <br />1.REFER TO INTERIOR ELEVATIONS FOR KITCHEN, BATH AND SERVICE ROOM <br />FINISHES. <br />2.ALL GLAZING SHALL COMPLY WITH THE CALIFORNIA RESIDENTIAL CODE AND <br />LOCAL ORDINANCES. REFER TO THE ENERGY CODE COMPLIANCE REPORT FOR <br />'U'-VALUE OF ALL GLAZING. <br />3.REFER TO GENERAL NOTE SHEETS FOR THE GENERAL CONSTRUCTION <br />METHODS AND CONDITIONS. <br />4.ALL EXTERIOR DOORS OF CONDITIONED SPACES SHALL BE FULLY WEATHER <br />STRIPPED. <br />5.CEILING AND SOFFIT HEIGHTS INDICATED ON PLANS ARE NOMINAL DIMENSIONS. <br />CEILING HEIGHTS NOTED AS 7'-0" WILL HAVE A ROUGH FRAMED HEIGHT OF 7'-1". <br />7'-0" CLEAR FINISHED OPENING IS REQUIRED PER THE CALIFORNIA RESIDENTIAL <br />CODE <br />6.EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR <br />OPENING OF NOT LESS THAN 5.7 SQ. FT. THE NET CLEAR HEIGHT OPENING <br />SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL BE NOT <br />LESS THAN 20 INCHES. IT SHALL HAVE THE BOTTOM OF THE CLEAR OPENING <br />NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. <br />7.VENTING SYSTEMS SHALL TERMINATE AT LEAST (4) FEET FROM A PROPERTY <br />LINE PER THE CMC. <br />BUILDING DEPARTMENT NOTES: <br />1. <br />THE STREET ADDRESS SHALL BE POSTED ON THE BUILDING IN SUCH A POSITION <br />TO BE PLAINLY LEGIBLE FROM STREET FRONTING THE PROPERTY. MUST BE <br />ILLUMINATED. <br />2.SEE ENERGY CODE COMPLIANCE REPORT FOR INSULATION VALUES. <br />3. <br />EXCEPT WHERE OTHERWISE NOTED IN THE CRC ALL FOAM PLASTIC OR FOAM <br />PLASTIC CORES IN MANUFACTURED ASSEMBLIES USED IN BUILDING <br />CONSTRUCTION SHALL HAVE A FLAME-SPREAD RATING OF NOT MORE THAN 75 <br />AND SHALL HAVE A SMOKE-DEVELOPED RATING OF NOT MORE THAN 450 WHEN <br />TESTED IN THE MAXIMUM THICKNESS INTENDED FOR USE IN ACCORDANCE WITH <br />ASTM E 84. <br />2X4 STUDS AT 16" o.c. U.N.O. <br />2X6 STUDS AT 16" o.c. U.N.O. <br />INTERIOR SOFFIT <br />4.IN AREAS WHERE EXPANSIVE OR COLLAPSIBLE SOILS ARE KNOWN TO EXIST, ALL <br />DWELLINGS SHALL HAVE A CONTROLLED METHOD OF WATER DRAINAGE FROM <br />THE ROOFS TO GROUND SURFACE. AT LEAST 5 FEET FROM FOUNDATION WALLS <br />TO AN APPROVED DRAINAGE SYSTEM PER THE CRC . <br />5.FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM <br />BACKERS OR FIBER-REINFORCED GYPSUM BACKERS IN COMPLIANCE WITH ASTM <br />C 1288, C 1325, C 1178 OR C 1278, RESPECTIVELY, AND INSTALLED IN <br />ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS SHALL BE USED AS <br />BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN <br />SHOWER AREAS. PER THE CRC. <br />6.A 10 MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED <br />NOT LESS THAN 6 INCHES SHALL BE PLACED BETWEEN THE CONCRETE FLOOR <br />SLAB AND THE PREPARED SUBGRADE PER CRC R506.2.3. WHEN A VAPOR <br />RETARDER IS REQUIRED, A CAPILLARY BREAK SHOULD BE INSTALLED PER <br />CGBSC 4.505.2.1. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />FLOOR PLAN & <br />BUILDING SECTIONS <br />A1-02SCALE : =FLOOR PLAN 1/4 11'-0" <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />WINDOW SCHEDULE:U-FACTOR: 0.3 SHGC: 0.23 <br />A NEW 2'-6"3'SLIDER VINYL WHITE <br />W H TYPE MATERIAL FINISH <br />DOOR SCHEDULE: <br />1 NEW 3'6'-8"SOLID CORE DOUGLAS FIR <br /> NEW 2-6"6'-8"HOLLOW CORE WOOD <br /> NEW 2'-6"6'-8"LOUVERED WOOD <br /> NEW 6'6'-8"SLIDING DOOR WOOD <br /> NEW 5'6'-8"BI-PASS WOOD <br /> NEW 1'-6"6'-8"SOLID CORE DOUGLAS FIR <br />W H TYPE MATERIAL <br />2 <br />3 <br />4 <br />5 <br />6 <br />SCALE : =SECTION 1/4 21'-0" <br />SCALE : =SECTION 1/4 31'-0" <br />1606 N Mabury St <br />4/28/2025