100 AMPS
<br />SUB PANEL
<br />WP
<br />S
<br />WP
<br />S
<br />MOTION SENSOR/
<br />PHOTOCELL
<br />MOTION SENSOR/
<br />PHOTOCELL
<br />H.B.
<br />VP
<br />SSSvs
<br />F.G.CWHW
<br />FOR ELEC
<br />CLOTHES DRYER
<br />CWF.G.
<br />GFCI BELOW
<br />FOR COOKTOP
<br />+80" GFCI
<br />FOR HOOD,
<br />RANGE HOOD
<br />160 CFM FOR
<br />ELECTRIC
<br />RANGE AND 280
<br />CFM FOR GAS
<br />RANGE
<br />KITCHEN HOOD,
<br />3 SONE MAX
<br />FOR ELECTRIC
<br />COOKTOP
<br />S
<br />+48"
<br />+48"
<br />+48"+48"
<br />S
<br />C
<br />CL
<br />S
<br />UTILITY PLAN
<br />A1-03SCALE : =UTILITY PLAN 1/4 11'-0"
<br />Client
<br />Project No:23-1107
<br />PHONE NO.
<br />NPS MANAGEMENT
<br />4401 ATLANTIC AVE #200
<br />LONG BEACH, CA 90807
<br />562-528-8100
<br />JWAIM DESIGN
<br />714-494-6810
<br />jwaimdesign@gmail.com
<br />CCOPYRIGHT
<br />It is the clients responsibility prior to or during construction to notify the architect in writing
<br />of any perceived errors or omissions in the plans and specifications of which a contractor
<br />thoroughly knowledgeable with the building codes and methods of construction should
<br />reasonably be aware. Written instructions addressing such perceived errors or omissions
<br />shall be received from the architect prior to the client or clients subcontractors proceeding
<br />with the work. The client will be responsible for any defects in construction if these
<br />procedures are not followed.
<br />GA
<br />R
<br />A
<br />G
<br />E
<br />
<br />A
<br />D
<br />U
<br />16
<br />0
<br />6
<br />
<br />N
<br />
<br />M
<br />A
<br />B
<br />U
<br />R
<br />Y
<br />
<br />S
<br />T
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />No.Date Description
<br />UTILITY LEGEND
<br />SWITCH ON VACANCY SENSOR
<br />SWITCH ON DIMMER
<br /> VP VAPOR PROOF FIXTURE
<br /> WP WEATHERPROOF FIXTURE OR OUTLET
<br /> K KEYLESS LIGHT FIXTURE
<br />110 OUTLET
<br />110 OUTLET WITH USB
<br />1/2 HOT DUPLEX
<br />QUAD PLEX
<br />220 DUPLEX
<br />GFCI DUPLEX (GFCI & AFCI DUPLEX AT KITCHEN AND LAUNDRY)
<br />GFCI DUPLEX (GFCI & AFCI 1/2 HOT DUPLEX AT KITCHEN)
<br />220 DISCONNECT
<br />SWITCH
<br />SWITCH (3-WAY)
<br />SWITCH (4-WAY)
<br />JUNCTION BOX (SHALL BE CONTROLLED BY DIMMER, VACANCY
<br />SENSOR, OR FAN SPEED CONTROL IF NO FIXTURE INSTALLED)
<br />HIGH EFFICACY CEILING MOUNTED LIGHT
<br />HIGH EFFICACY RECESSED CAN LIGHT
<br />HIGH EFFICACY PENDANT LIGHT
<br />HIGH EFFICACY WALL MOUNTED LIGHT
<br />HIGH EFFICACY UNDER CABINET FIXTURE
<br />ADDRESS LIGHT - HIGH EFFICACY
<br />SURFACE MOUNTED FIXTURE
<br />HIGH EFFICACY TRACK LIGHT
<br />HIGH EFFICACY EYEBALL LIGHT
<br />THERMOSTAT
<br />PUSHBUTTON
<br />CHIMES
<br />OPTIONAL SECURITY
<br />110V SMOKE DETECTOR TO SOUND ALARM AUDIBLE IN ALL
<br />SLEEPING AREAS BE HARDWIRED WITH BATTERY BACKUP AND
<br />INTERCONNECTED
<br />CARBON MONOXIDE DETECTOR INTERCONNECTED
<br />COMBINATION CARBON MONOXIDE/SMOKE DETECTOR TO SOUND
<br />ALARM AUDIBLE IN ALL SLEEPING AREAS. HARDWIRE WITH
<br />BATTERY BACKUP AND INTERCONNECTED
<br />EXHAUST FAN 50 CFM MIN WITH HUMIDISTAT.
<br />COMBINATION OF EXHAUST FAN & HIGH EFFICACY LIGHT
<br />WHOLE BUILDING VENTILATION FAN
<br />CEILING FAN
<br />TELEPHONE OUTLET W/ "CATEGORY V" WIRE
<br />TV OUTLET W/ RG-6 COAXIAL CABLE
<br />"CATEGORY V" WIRE W/ RG-6 COAXIAL CABLE
<br />FUEL GAS
<br />FIREPLACE KEY (LOOSE)
<br />ELECTRICAL PANEL. MIN. SIZE 3-WIRE, 100-AMP PANEL. VERIFY
<br />SIZE & LOCATION
<br />ELECTRIC VEHICLE SERVICE EQUIPMENT
<br />HOSEBIB WITH NON-REMOVABLE BACKFLOW PREVENTION DEVICE
<br />RECESSED STUB-OUT FOR ICE-MAKER
<br />FS FIRE SPRINKLER RISER
<br />UTILITY NOTES
<br />1.FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED
<br />AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE
<br />EVENT OF IGNITION OR FLAME FAILURE PER CMC AND CPC.
<br />2.GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND
<br />HAVE ITS OPENING SEALED ON OUTSIDE PER CPC 1211.0.
<br />3.ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE AFCI & GFCI
<br />PROTECTED IN KITCHEN AND LAUNDRY AREAS PER CEC 210.52 (C) & 210.12 (A).
<br />4.IN ALL AREAS SPECIFIED IN CEC 210.52, ALL 125-VOLT, 15 AND 20 AMP
<br />RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES PER CEC
<br />406.12 (A).
<br /> EXCEPTIONS:
<br />1. RECEPTACLES LOCATED MORE THAN 1.7 M (5'-6") ABOVE THE FLOOR
<br />2. RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE.
<br />3. SINGLE RECEPTACLE OR A DUPLEX RECEPTACLE OR TWO APPLIANCES
<br />LOCATED WITHIN A DEDICATED SPACE FOR EACH APPLIANCE THAT, IN NORMAL
<br />USE, IS NOT EASILY MOVED FROM ONE PLACE TO ANOTHER AND THAT IS CORD
<br />AND PLUG CONNECTED.
<br />5.PROVIDE TWO OR MORE 20-AMP SMALL-APPLIANCE BRANCH CIRCUITS FOR ALL
<br />RECEPTACLE OUTLETS SPECIFIED BY CEC 210.52 (B) PER CEC 210.11 (C)(1).
<br />PROVIDE A DEDICATED 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY
<br />RECEPTACLE PER CEC 201.11 (C)(2). BATHROOM BRANCH CIRCUITS - AT LEAST
<br />ONE 20-AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM
<br />RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER
<br />CEC 210.11(C)(3).
<br />6.ALL 120-VOLT, SINGLE-PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING
<br />OUTLETS INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING
<br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
<br />RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR
<br />ROOMS OR AREAS SHALL BE PROTECTED BY LISTED ARC-FAULT CIRCUIT
<br />INTERRUPTER (AFCI), COMBINATION TYPE, INSTALLED TO PROVIDE
<br />PROTECTION OF THE BRANCH CIRCUIT PER CEC 210.12 (A)(1).
<br />7.PROVIDE A GROUNDING ELECTRODE SYSTEM PER CEC 250.50 - 20 FEET BARE
<br />COPPER #4 CONCRETE ENCASED UFER.
<br />8.PROVIDE MECHANICAL VENTILATION AND APPLICABLE CONTROLS IN ALL
<br />ROOMS CONTAINING BATHING FIXTURES PER CRC R303.3 EXCEPTION AND CMC
<br />CHAPTER 4.
<br />9.USE CAT-5 FOR STANDARD TELEPHONE WIRING
<br />10.ALL RECESSED CAN LIGHTS SHALL BE AIRTIGHT AND IC RATED AND MEET
<br />JA8-2016/JA-2016-E REQUIREMENTS PER CALIFORNIA ENERGY CODE SECTION
<br />150.0(K)(C).
<br />11.PROVIDE UV RESISTANT COVERING AT AC CONDENSER FOR SUCTION LINE
<br />INSULATION AT EXPOSED EXTERIOR LOCATIONS.
<br />12.KITCHEN HOOD FAN SHALL HAVE A MIN. AIR FLOW OF 110 CFM AND BE
<br />EXHAUSTED TO THE OUTDOORS.
<br />13.GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM,
<br />LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION
<br />ROOM, OR SIMILAR ROOM, OR AREA OF DWELLING UNITS, RECEPTACLE
<br />OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL
<br />PROVISIONS SPECIFIED IN THE FOLLOWING ARTICLES. SPACING CEC
<br />210.52(A)(1), WALL SPACE CEC 210.52(A)(2) & FLOOR RECEPTACLES CEC
<br />210.52(A)(3).
<br />14.COUNTERTOPS: IN KITCHEN & DINING ROOMS OF DWELLING UNITS,
<br />RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC.
<br />NO MORE THAN (5) DUPLEX RECEPTACLE OUTLETS SERVING THE REQUIRED
<br />COUNTERTOP RECEPTACLES SHALL BE INSTALLED ON ANY SMALL APPLIANCE
<br />BRANCH CIRCUIT PER THE CEC.
<br />15.PROVIDE 1 FOOT CANDLE ON EVERY STAIR TREAD AND LANDING PER THE CRC
<br />R303.7.
<br />16.THE FOLLOWING FASTENED-IN-PLACE APPLIANCES ARE REQUIRED TO HAVE A
<br />SEPARATE MINIMUM 20-AMPERE CIRCUIT: DISHWASHER, TRASH COMPACTOR,
<br />MICROWAVE OVEN, AND HYDRO-MASSAGE BATHTUB. THE CLOTHES WASHER
<br />CIRCUIT MAY SERVE ONE (1) ADDITIONAL OUTLET IN THE LAUNDRY AREA PER
<br />CEC 210.11 (C).
<br />17.IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA
<br />OF A DWELLING UNIT, THE TWO OR MORE 20-AMPERE SMALL-APPLIANCE
<br />BRANCH CIRCUITS REQUIRED BY 210.11(B) SHALL SERVE ALL WALL AND FLOOR
<br />RECEPTACLE OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP OUTLETS
<br />COVERED BY 210.52(C), AND RECEPTACLE OUTLETS FOR REFRIGERATION
<br />EQUIPMENT PER CEC 210.52(B)(1).
<br />18.THE MAXIMUM NUMBER OF OUTLETS ON A 20-AMPERE , 125-VOLT CIRCUIT USED
<br />EITHER EXCLUSIVELY FOR RECEPTACLES OR EXCLUSIVELY FOR LIGHTING
<br />FIXTURES OR FOR ANY COMBINATION OF RECEPTACLES AND LIGHTING
<br />FIXTURES SHALL BE 12 PER CEC210.20 (B)(2) AND TABLE 210.21(B)(2).
<br />19.OUTLET BOXES OR OUTLET BOX SYSTEMS USED AS THE SOLE SUPPORT OF A
<br />CEILING-SUSPENDED (PADDLE) FAN SHALL BE LISTED, SHALL BE MARKED BY
<br />THEIR MANUFACTURER AS SUITABLE FOR THIS PURPOSE, AND SHALL NOT
<br />SUPPORT CEILING-SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 32KG
<br />(70 LB). FOR OUTLET BOXES OR OUTLET BOX SYSTEMS DESIGNED TO SUPPORT
<br />CEILING-SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 16 KG (35 LB),
<br />THE REQUIRED MARKING SHALL INCLUDE THE MAXIMUM WEIGHT TO BE
<br />SUPPORTED PER CEC 314.27(C).
<br />20.ALL LUMINAIRES (FIXTURES) INSTALLED IN DAMP LOCATIONS SHALL BE
<br />MARKED, "SUITABLE FOR WET LOCATIONS" OR "SUITABLE FOR DAMP
<br />LOCATIONS" PER CEC 410.10(A).
<br />21.FOR ALL EMPTY J-BOXES MORE THAN 5' ABOVE THE FLOOR: EMPTY J-BOXES
<br />WITH UNINSTALLED FIXTURES SHALL NOT EXCEED TOTAL NUMBER OF
<br />BEDROOMS, AND SHALL BE ON A VACANCY SENSOR, DIMMER, OR FAN SPEED
<br />CONTROL PER CALIFORNIA ENERGY CODE SECTION 150.0(K)1.B.
<br />22.ALL INDOOR AND OUTDOOR LIGHTING TO BE HIGH EFFICACY PER CALIFORNIA
<br />ENERGY CODE SECTION 150.0(K)1.A.
<br />23.ALL BELOW CABINET LIGHTING TO BE SWITCHED SEPARATELY PER CALIFORNIA
<br />ENERGY CODE SECTION 150.0(K)2.L.
<br />24.WHOLE BUILDING VENTILATION FAN SIZE AND DUCTED PER ASHRAE 62.2-2007. 1
<br />SONE MAX. SEE CF-1R & MF-1R FOR ADDITIONAL INFO. (FAN IS SWITCHED
<br />SEPARATELY FROM THE LIGHTING. PROVIDE LABEL NEXT TO SWITCH STATING
<br />THE FAN CONTROL SHOULD BE ON AT ALL TIMES WHEN THE BUILDING IS
<br />OCCUPIED, UNLESS THERE IS SEVERE OUTDOOR AIR CONTAMINATION.)
<br />25.SMOKE ALARMS SHALL COMPLY WITH NFPA 72 AND CRC R314. SMOKE ALARMS
<br />SHALL BE LISTED IN ACCORDANCE WITH UL 217. COMBINATION SMOKE AND
<br />CARBON MONOXIDE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217
<br />AND UL 2034 AND COMPLY WITH CRC 315.4.
<br />26.CARBON MONOXIDE ALARMS SHALL COMPLY WITH CRC R315. CARBON
<br />MONOXIDE SHALL BE LISTED IN ACCORDANCE WITH UL 2034.
<br />27.OUTDOOR LIGHTING MUST BE CONTROLLED BY AN ON/OFF SWITCH AND:
<br />- PHOTOCELL AND MOTION SENSOR OR
<br />-PHOTO-CONTROL AND AUTOMATIC TIME SWITCH OR
<br />-ASTRONOMICAL TIME CLOCK OR
<br />-AN ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) PER CALIFORNIA ENERGY
<br />CODE SECTION 150.0(k)3.A.
<br />28.ELECTRIC VEHICLE CHARGING STATION TO COMPLY WITH CEC ARTICLE 625.
<br />OUTLET(S) INSTALLED FOR THE PURPOSE OF CHARGING ELECTRIC VEHICLES
<br />ARE REQUIRED TO BE SUPPLIED BY A SEPARATE BRANCH CIRCUIT WITH NO
<br />OTHER OUTLETS.
<br />29.FLUORESCENT LIGHT FIXTURES SHALL BE CONTROLLED BY PIN-BASED
<br />BALLAST OR GU-24 SOCKET.
<br />30.ELEC SUB PANEL - 100A: PER CALGREEN SECTION 4.106.4.1.1 PROVIDE 40A
<br />DEDICATED CIRCUIT LABELED EV CAPABLE
<br />31.ADU ELEC SUB PANEL - 100A - DIDICATED CIRCUITS INCLUDE THE FOLLOWING:
<br />31.1 TANKLESS WATER HEATER - 125V 20A
<br />31.2 ELECTRIC COOK TOP - 240V 50A
<br />31.3 ELECTRIC CLOTHES DRYER - 240V 30A
<br />32.ESS READY INTERCONNECTION WITH A MINIMUM BACKED-UP CAPACITY OF 60A
<br />AND A MINIMUM OF (4) ESS-SUPPLIED BRANCH CIRCUITS TO INCLUDE THE
<br />REFRIGERATOR, ONE LIGHTING CIRCUIT LOCATED NEAR PRIMARY EGRESS AND
<br />AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE
<br />OUTLET.
<br />SSSSSSSSS
<br />SS
<br />3
<br />SSSSSSS
<br />SSS
<br />4
<br />SSSSSS
<br />J
<br />T
<br />P.B.
<br />S
<br />C
<br />S
<br />C
<br />TV
<br />F.G.
<br />ELEC
<br />H.B.
<br />CW
<br />EVSE
<br />USB
<br />SVS
<br />SD
<br />ALL RECESSED LIGHTING AND LED LIGHTING SHALL MEET THE REQUIREMENTS
<br />OF JA8-2016 PER CALIFORNIA ENERGY CODE SECTION 150.0(K)1.C. ALL JA8-2016
<br />COMPLIANT LUMINARIES TO BE ON VACANCY SENSORS OR DIMMERS, UNLESS
<br />IN HALLWAYS OR CLOSETS LESS THAN 70 SQ. FT. PER CALIFORNIA ENERGY
<br />CODE SECTION 150.0(K)2.K.
<br />LIGHTING CONTROLS:
<br />1606 N Mabury St
<br />4/28/2025
|