100 AMPS <br />SUB PANEL <br />WP <br />S <br />WP <br />S <br />MOTION SENSOR/ <br />PHOTOCELL <br />MOTION SENSOR/ <br />PHOTOCELL <br />H.B. <br />VP <br />SSSvs <br />F.G.CWHW <br />FOR ELEC <br />CLOTHES DRYER <br />CWF.G. <br />GFCI BELOW <br />FOR COOKTOP <br />+80" GFCI <br />FOR HOOD, <br />RANGE HOOD <br />160 CFM FOR <br />ELECTRIC <br />RANGE AND 280 <br />CFM FOR GAS <br />RANGE <br />KITCHEN HOOD, <br />3 SONE MAX <br />FOR ELECTRIC <br />COOKTOP <br />S <br />+48" <br />+48" <br />+48"+48" <br />S <br />C <br />CL <br />S <br />UTILITY PLAN <br />A1-03SCALE : =UTILITY PLAN 1/4 11'-0" <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />UTILITY LEGEND <br />SWITCH ON VACANCY SENSOR <br />SWITCH ON DIMMER <br /> VP VAPOR PROOF FIXTURE <br /> WP WEATHERPROOF FIXTURE OR OUTLET <br /> K KEYLESS LIGHT FIXTURE <br />110 OUTLET <br />110 OUTLET WITH USB <br />1/2 HOT DUPLEX <br />QUAD PLEX <br />220 DUPLEX <br />GFCI DUPLEX (GFCI & AFCI DUPLEX AT KITCHEN AND LAUNDRY) <br />GFCI DUPLEX (GFCI & AFCI 1/2 HOT DUPLEX AT KITCHEN) <br />220 DISCONNECT <br />SWITCH <br />SWITCH (3-WAY) <br />SWITCH (4-WAY) <br />JUNCTION BOX (SHALL BE CONTROLLED BY DIMMER, VACANCY <br />SENSOR, OR FAN SPEED CONTROL IF NO FIXTURE INSTALLED) <br />HIGH EFFICACY CEILING MOUNTED LIGHT <br />HIGH EFFICACY RECESSED CAN LIGHT <br />HIGH EFFICACY PENDANT LIGHT <br />HIGH EFFICACY WALL MOUNTED LIGHT <br />HIGH EFFICACY UNDER CABINET FIXTURE <br />ADDRESS LIGHT - HIGH EFFICACY <br />SURFACE MOUNTED FIXTURE <br />HIGH EFFICACY TRACK LIGHT <br />HIGH EFFICACY EYEBALL LIGHT <br />THERMOSTAT <br />PUSHBUTTON <br />CHIMES <br />OPTIONAL SECURITY <br />110V SMOKE DETECTOR TO SOUND ALARM AUDIBLE IN ALL <br />SLEEPING AREAS BE HARDWIRED WITH BATTERY BACKUP AND <br />INTERCONNECTED <br />CARBON MONOXIDE DETECTOR INTERCONNECTED <br />COMBINATION CARBON MONOXIDE/SMOKE DETECTOR TO SOUND <br />ALARM AUDIBLE IN ALL SLEEPING AREAS. HARDWIRE WITH <br />BATTERY BACKUP AND INTERCONNECTED <br />EXHAUST FAN 50 CFM MIN WITH HUMIDISTAT. <br />COMBINATION OF EXHAUST FAN & HIGH EFFICACY LIGHT <br />WHOLE BUILDING VENTILATION FAN <br />CEILING FAN <br />TELEPHONE OUTLET W/ "CATEGORY V" WIRE <br />TV OUTLET W/ RG-6 COAXIAL CABLE <br />"CATEGORY V" WIRE W/ RG-6 COAXIAL CABLE <br />FUEL GAS <br />FIREPLACE KEY (LOOSE) <br />ELECTRICAL PANEL. MIN. SIZE 3-WIRE, 100-AMP PANEL. VERIFY <br />SIZE & LOCATION <br />ELECTRIC VEHICLE SERVICE EQUIPMENT <br />HOSEBIB WITH NON-REMOVABLE BACKFLOW PREVENTION DEVICE <br />RECESSED STUB-OUT FOR ICE-MAKER <br />FS FIRE SPRINKLER RISER <br />UTILITY NOTES <br />1.FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED <br />AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE <br />EVENT OF IGNITION OR FLAME FAILURE PER CMC AND CPC. <br />2.GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND <br />HAVE ITS OPENING SEALED ON OUTSIDE PER CPC 1211.0. <br />3.ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE AFCI & GFCI <br />PROTECTED IN KITCHEN AND LAUNDRY AREAS PER CEC 210.52 (C) & 210.12 (A). <br />4.IN ALL AREAS SPECIFIED IN CEC 210.52, ALL 125-VOLT, 15 AND 20 AMP <br />RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES PER CEC <br />406.12 (A). <br /> EXCEPTIONS: <br />1. RECEPTACLES LOCATED MORE THAN 1.7 M (5'-6") ABOVE THE FLOOR <br />2. RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. <br />3. SINGLE RECEPTACLE OR A DUPLEX RECEPTACLE OR TWO APPLIANCES <br />LOCATED WITHIN A DEDICATED SPACE FOR EACH APPLIANCE THAT, IN NORMAL <br />USE, IS NOT EASILY MOVED FROM ONE PLACE TO ANOTHER AND THAT IS CORD <br />AND PLUG CONNECTED. <br />5.PROVIDE TWO OR MORE 20-AMP SMALL-APPLIANCE BRANCH CIRCUITS FOR ALL <br />RECEPTACLE OUTLETS SPECIFIED BY CEC 210.52 (B) PER CEC 210.11 (C)(1). <br />PROVIDE A DEDICATED 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY <br />RECEPTACLE PER CEC 201.11 (C)(2). BATHROOM BRANCH CIRCUITS - AT LEAST <br />ONE 20-AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM <br />RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER <br />CEC 210.11(C)(3). <br />6.ALL 120-VOLT, SINGLE-PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING <br />OUTLETS INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING <br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, <br />RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR <br />ROOMS OR AREAS SHALL BE PROTECTED BY LISTED ARC-FAULT CIRCUIT <br />INTERRUPTER (AFCI), COMBINATION TYPE, INSTALLED TO PROVIDE <br />PROTECTION OF THE BRANCH CIRCUIT PER CEC 210.12 (A)(1). <br />7.PROVIDE A GROUNDING ELECTRODE SYSTEM PER CEC 250.50 - 20 FEET BARE <br />COPPER #4 CONCRETE ENCASED UFER. <br />8.PROVIDE MECHANICAL VENTILATION AND APPLICABLE CONTROLS IN ALL <br />ROOMS CONTAINING BATHING FIXTURES PER CRC R303.3 EXCEPTION AND CMC <br />CHAPTER 4. <br />9.USE CAT-5 FOR STANDARD TELEPHONE WIRING <br />10.ALL RECESSED CAN LIGHTS SHALL BE AIRTIGHT AND IC RATED AND MEET <br />JA8-2016/JA-2016-E REQUIREMENTS PER CALIFORNIA ENERGY CODE SECTION <br />150.0(K)(C). <br />11.PROVIDE UV RESISTANT COVERING AT AC CONDENSER FOR SUCTION LINE <br />INSULATION AT EXPOSED EXTERIOR LOCATIONS. <br />12.KITCHEN HOOD FAN SHALL HAVE A MIN. AIR FLOW OF 110 CFM AND BE <br />EXHAUSTED TO THE OUTDOORS. <br />13.GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM, <br />LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION <br />ROOM, OR SIMILAR ROOM, OR AREA OF DWELLING UNITS, RECEPTACLE <br />OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL <br />PROVISIONS SPECIFIED IN THE FOLLOWING ARTICLES. SPACING CEC <br />210.52(A)(1), WALL SPACE CEC 210.52(A)(2) & FLOOR RECEPTACLES CEC <br />210.52(A)(3). <br />14.COUNTERTOPS: IN KITCHEN & DINING ROOMS OF DWELLING UNITS, <br />RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC. <br />NO MORE THAN (5) DUPLEX RECEPTACLE OUTLETS SERVING THE REQUIRED <br />COUNTERTOP RECEPTACLES SHALL BE INSTALLED ON ANY SMALL APPLIANCE <br />BRANCH CIRCUIT PER THE CEC. <br />15.PROVIDE 1 FOOT CANDLE ON EVERY STAIR TREAD AND LANDING PER THE CRC <br />R303.7. <br />16.THE FOLLOWING FASTENED-IN-PLACE APPLIANCES ARE REQUIRED TO HAVE A <br />SEPARATE MINIMUM 20-AMPERE CIRCUIT: DISHWASHER, TRASH COMPACTOR, <br />MICROWAVE OVEN, AND HYDRO-MASSAGE BATHTUB. THE CLOTHES WASHER <br />CIRCUIT MAY SERVE ONE (1) ADDITIONAL OUTLET IN THE LAUNDRY AREA PER <br />CEC 210.11 (C). <br />17.IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA <br />OF A DWELLING UNIT, THE TWO OR MORE 20-AMPERE SMALL-APPLIANCE <br />BRANCH CIRCUITS REQUIRED BY 210.11(B) SHALL SERVE ALL WALL AND FLOOR <br />RECEPTACLE OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP OUTLETS <br />COVERED BY 210.52(C), AND RECEPTACLE OUTLETS FOR REFRIGERATION <br />EQUIPMENT PER CEC 210.52(B)(1). <br />18.THE MAXIMUM NUMBER OF OUTLETS ON A 20-AMPERE , 125-VOLT CIRCUIT USED <br />EITHER EXCLUSIVELY FOR RECEPTACLES OR EXCLUSIVELY FOR LIGHTING <br />FIXTURES OR FOR ANY COMBINATION OF RECEPTACLES AND LIGHTING <br />FIXTURES SHALL BE 12 PER CEC210.20 (B)(2) AND TABLE 210.21(B)(2). <br />19.OUTLET BOXES OR OUTLET BOX SYSTEMS USED AS THE SOLE SUPPORT OF A <br />CEILING-SUSPENDED (PADDLE) FAN SHALL BE LISTED, SHALL BE MARKED BY <br />THEIR MANUFACTURER AS SUITABLE FOR THIS PURPOSE, AND SHALL NOT <br />SUPPORT CEILING-SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 32KG <br />(70 LB). FOR OUTLET BOXES OR OUTLET BOX SYSTEMS DESIGNED TO SUPPORT <br />CEILING-SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 16 KG (35 LB), <br />THE REQUIRED MARKING SHALL INCLUDE THE MAXIMUM WEIGHT TO BE <br />SUPPORTED PER CEC 314.27(C). <br />20.ALL LUMINAIRES (FIXTURES) INSTALLED IN DAMP LOCATIONS SHALL BE <br />MARKED, "SUITABLE FOR WET LOCATIONS" OR "SUITABLE FOR DAMP <br />LOCATIONS" PER CEC 410.10(A). <br />21.FOR ALL EMPTY J-BOXES MORE THAN 5' ABOVE THE FLOOR: EMPTY J-BOXES <br />WITH UNINSTALLED FIXTURES SHALL NOT EXCEED TOTAL NUMBER OF <br />BEDROOMS, AND SHALL BE ON A VACANCY SENSOR, DIMMER, OR FAN SPEED <br />CONTROL PER CALIFORNIA ENERGY CODE SECTION 150.0(K)1.B. <br />22.ALL INDOOR AND OUTDOOR LIGHTING TO BE HIGH EFFICACY PER CALIFORNIA <br />ENERGY CODE SECTION 150.0(K)1.A. <br />23.ALL BELOW CABINET LIGHTING TO BE SWITCHED SEPARATELY PER CALIFORNIA <br />ENERGY CODE SECTION 150.0(K)2.L. <br />24.WHOLE BUILDING VENTILATION FAN SIZE AND DUCTED PER ASHRAE 62.2-2007. 1 <br />SONE MAX. SEE CF-1R & MF-1R FOR ADDITIONAL INFO. (FAN IS SWITCHED <br />SEPARATELY FROM THE LIGHTING. PROVIDE LABEL NEXT TO SWITCH STATING <br />THE FAN CONTROL SHOULD BE ON AT ALL TIMES WHEN THE BUILDING IS <br />OCCUPIED, UNLESS THERE IS SEVERE OUTDOOR AIR CONTAMINATION.) <br />25.SMOKE ALARMS SHALL COMPLY WITH NFPA 72 AND CRC R314. SMOKE ALARMS <br />SHALL BE LISTED IN ACCORDANCE WITH UL 217. COMBINATION SMOKE AND <br />CARBON MONOXIDE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217 <br />AND UL 2034 AND COMPLY WITH CRC 315.4. <br />26.CARBON MONOXIDE ALARMS SHALL COMPLY WITH CRC R315. CARBON <br />MONOXIDE SHALL BE LISTED IN ACCORDANCE WITH UL 2034. <br />27.OUTDOOR LIGHTING MUST BE CONTROLLED BY AN ON/OFF SWITCH AND: <br />- PHOTOCELL AND MOTION SENSOR OR <br />-PHOTO-CONTROL AND AUTOMATIC TIME SWITCH OR <br />-ASTRONOMICAL TIME CLOCK OR <br />-AN ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) PER CALIFORNIA ENERGY <br />CODE SECTION 150.0(k)3.A. <br />28.ELECTRIC VEHICLE CHARGING STATION TO COMPLY WITH CEC ARTICLE 625. <br />OUTLET(S) INSTALLED FOR THE PURPOSE OF CHARGING ELECTRIC VEHICLES <br />ARE REQUIRED TO BE SUPPLIED BY A SEPARATE BRANCH CIRCUIT WITH NO <br />OTHER OUTLETS. <br />29.FLUORESCENT LIGHT FIXTURES SHALL BE CONTROLLED BY PIN-BASED <br />BALLAST OR GU-24 SOCKET. <br />30.ELEC SUB PANEL - 100A: PER CALGREEN SECTION 4.106.4.1.1 PROVIDE 40A <br />DEDICATED CIRCUIT LABELED EV CAPABLE <br />31.ADU ELEC SUB PANEL - 100A - DIDICATED CIRCUITS INCLUDE THE FOLLOWING: <br />31.1 TANKLESS WATER HEATER - 125V 20A <br />31.2 ELECTRIC COOK TOP - 240V 50A <br />31.3 ELECTRIC CLOTHES DRYER - 240V 30A <br />32.ESS READY INTERCONNECTION WITH A MINIMUM BACKED-UP CAPACITY OF 60A <br />AND A MINIMUM OF (4) ESS-SUPPLIED BRANCH CIRCUITS TO INCLUDE THE <br />REFRIGERATOR, ONE LIGHTING CIRCUIT LOCATED NEAR PRIMARY EGRESS AND <br />AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE <br />OUTLET. <br />SSSSSSSSS <br />SS <br />3 <br />SSSSSSS <br />SSS <br />4 <br />SSSSSS <br />J <br />T <br />P.B. <br />S <br />C <br />S <br />C <br />TV <br />F.G. <br />ELEC <br />H.B. <br />CW <br />EVSE <br />USB <br />SVS <br />SD <br />ALL RECESSED LIGHTING AND LED LIGHTING SHALL MEET THE REQUIREMENTS <br />OF JA8-2016 PER CALIFORNIA ENERGY CODE SECTION 150.0(K)1.C. ALL JA8-2016 <br />COMPLIANT LUMINARIES TO BE ON VACANCY SENSORS OR DIMMERS, UNLESS <br />IN HALLWAYS OR CLOSETS LESS THAN 70 SQ. FT. PER CALIFORNIA ENERGY <br />CODE SECTION 150.0(K)2.K. <br />LIGHTING CONTROLS: <br />1606 N Mabury St <br />4/28/2025