Laserfiche WebLink
8' <br />- <br />1 <br />" <br />F.FL. <br />T.O.PL. <br />11 <br />' <br />- <br />8 <br />" <br />BUILDING HEIGHT <br />6 <br />AD-01 <br />F.FL. <br />T.O.PL. <br />6' <br />- <br />8 <br />" <br />8' <br />- <br />1 <br />" <br />HEADER HT. <br />7 <br />AD-01 <br />2 <br />AD-01 <br />5 <br />AD-01 <br />F.FL. <br />T.O.PL. <br />6' <br />- <br />8 <br />" <br />8' <br />- <br />1 <br />" <br />HEADER HT. <br />2 <br />AD-02 <br />1 <br />AD-02 <br />F.FL. <br />T.O.PL. <br />8' <br />- <br />1 <br />" <br />ELEC. <br />PANEL <br />5:12 <br />5:12 <br />RIDGE <br />ROOF: ASPHALT SHINGLE <br />3' <br />- <br />0 <br />" <br />EA <br />V <br />E <br />1'-6" <br />RAKE <br />1.ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE INTERIOR <br />CONCRETE FLOOR SLAB AT THE FIRST FLOOR OR TOP OF <br />SHEATHING AT THE UPPER FLOORS FLOOR. <br />2.REFER TO DETAILS FOR MINIMUM WINDOW, DOOR AND WALL VENT <br />MOISTURE BARRIER INSTALLATION REQUIREMENTS. <br />3.PROVIDE (2) LAYERS OF MIN. GRADE "D" BUILDING PAPER AT WOOD <br />SHEATHED WALLS RECEIVING EXTERIOR PLASTER. <br />4.ALL HORIZONTAL SURFACES WILL RECEIVE BUILDING PAPER OVER <br />SELF ADHERING, SELF SEALING FLASHING WEATHER BOARD LAPPED <br />6" MINIMUM WITH BUILDING PAPER PRIOR TO THE APPLICATION OF <br />WIRE LATH AND PLASTER. <br />5.ALL STUD WALLS & CEILINGS EXTENDING INTO A SOFFIT WILL BE <br />PREBOARDED WITH GYP-BD PRIOR TO SOFFIT INSTALLATION. <br />6.DUCT TERMINATIONS TO OCCUR PER APPLIANCE MANUFACTURERS <br />REQUIREMENTS VERIFY DISTANCE FROM WINDOW OR DOOR <br />OPENINGS INTO DWELLING UNIT. <br />BUILDING ELEVATIONS <br />A1-04SCALE : =WEST ELEVATION 1/4"11'-0" <br />SCALE : =NORTH ELEVATION 1/4"21'-0" <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />SCALE : =EAST ELEVATION 1/4"41'-0" <br />SCALE : =SOUTH ELEVATION 1/4"51'-0" <br />SCALE : =ROOF PLAN 1/8"31'-0" <br />1606 N Mabury St <br />4/28/2025