My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1902 W Monica Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Monica Ln
>
1902 W Monica Ln
>
1902 W Monica Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:28 PM
Creation date
6/15/2025 12:44:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20184530
Full Address
1902 W Monica Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
By: J.R. <br />Date: 10/7/24 <br />Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7‐16) <br />Vult =100 mph Kzt =1.00 (sec 26.8.2)h = 15 ft <br />Exposure Category = C Kz = 0.85 (sec 26.10.1) <br />Roof Zone = 2 Kd =0.85 (sec 26.6) <br />Roof θ = 7‐27 deg Ke =1.00 (sec 26.9) <br />qh = 0.00256 Kz Kzt Kd Ke V2 qh =18.50 (eq. 26.10‐1) <br />GPp =‐2 uplift γE =1.5 (sec 29.4.4) <br />γa =0.78 (fig 29.4‐8) <br />γE =1.5 FIG 29.4‐7)γc =0.94 (fig 29.4‐7)hpt =0 <br />γa =0.78 (fig 29.4‐8)γp =0.9 (fig 29.4‐7)ω =0.00 deg (panel tilt) <br />GPp =‐2 uplift GCrm =1.4 uplift <br />p = qh (GPp) γE γa (eq 29.4‐7)p = qh (GCrn) γE γC γp (eq 29.4‐6) <br />p =‐43.2 p.s.f.p =32.8 p.s.f. <br />Check Anchorage to Existing Structur <br />0.6DL ‐ 0.6W controlling load combination (eq. 16‐15 for ASD) <br />DL = 2.9 p.s.f.dead load of panel (including rack system) <br />W = 43.2 p.s.f.wind load normal to face of panel <br />Arealag =11.3 sq. ft.area tributary to each anchor <br />SPanc =4.00 ft.spacing of anchors <br />Puplift = Arealag (0.6DL - 0.6W) =273.6 lbs.total uplift on anchor <br />Material = DFL lumber anchor material <br />Dialag =5/16 in.diameter of screw <br />Penlag = 2.5 in.min. penetration to existing framing <br />W lag =266 lb/in.withdrawal load per in. of penetration per NDS Table 11.2A <br />CD = 1.6 load duration factor for wind per NDS Table 2.3.2 <br />Ct = 0.8 temperature factor per NDS Table 2.3.3 <br />Noscrews =1 number of screws in withdrawal <br />Pallow = Penlag (Wlag CD Ct) * Noscrews =851.2 lbs.total allowable withdrawal on anchor <br />Puplift <br />Pallow <br />Anchorage =USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION <br />Wind Uplift Anchorage <br />Flush Mounted Panels ‐ ASCE Section <br />29.4.4 (where applicable) <br />Flat Roof Panels ‐ ASCE Section 29.4.3 <br />(where applicable) <br />=0.32 < 1.00 Anchor is OK! <br />10/7/2024 10:20 AM <br />6 of 7 <br />©McPherson Engineering <br />1902 W Monica Ln <br />12/2/2024
The URL can be used to link to this page
Your browser does not support the video tag.