POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />CAUTION: MULTIPLE <br />SOURCES OF POWER <br />SERVICE BY QUALIFIED PERSONNEL ONLY <br />N <br />DESIGNER: TAYLOR BICKFORD <br />NEW PV SYSTEM: 9600W DC / 6960W AC <br />Jose Luis Melgoza <br />1902 Monica Ln, Santa Ana, CA 92706 <br />APN: 10104209 <br />DATE: 10/4/2024 TIME: 09:43 AM <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE:DESIGNER SIGNATURE: <br />ROOFTOP <br />PV ARRAY <br />UTILITY METER AND <br />MAIN SERVICE PANEL <br />SUB PANEL <br />YOU ARE HERE <br />PLACARD & <br /> PLACARD MAP <br />007 PP1 <br />LABELING PLAN <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />INSTALLER NOTES: <br />PROPERTY MAP <br />NOTES: <br />FORMAT <br />1. WHITE LETTERING ON A RED BACKGROUND <br />2. MINIMUM 3/8 INCHES LETTER HEIGHT <br />3. ALL LETTERS SHALL BE CAPITALIZED <br />4. ARIAL OR SIMILAR FONT (NON-BOLD) <br />6"X6" DISCONNECT DIRECTORY PLAQUE <br />INSTALL AT MAIN SERVICE PANEL <br />MATERIAL <br />REFLECTIVE, WEATHER RESISTANT <br />MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(USE UL-969 AS STANDARD FOR <br />WEATHER RATING). <br />DURABLE ADHESIVE MATERIALS <br />1902 MONICA LN, SANTA ANA, CA 92706 <br />JURISDICTION STAMPS <br />BACKUP GATEWAY <br />AC DISCONNECT <br />IQ COMBINER <br />BATTERY <br />THIS PANEL IS FED BY <br />MULTIPLE SOURCES <br />(UTILITY & SOLAR)6 <br />[690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT <br />CONTAINING OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO A BUSBAR OR CONDUCTORS <br />SUPPLIED FROM MULTIPLE SOURCES <br />9 <br />[705.12(B)(3)(3)] PLACE THIS LABEL AT P.O.C. TO <br />SERVICE DISTRIBUTION EQUIPMENT <br />WARNING! <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL OVERCURRRENT <br />DEVICES, EXCLUDING MAIN SUPPLY <br />OVERCURRENT DEVICE, SHALL NOT <br />EXCEED AMPACITY OF BUSBAR <br />[690.14(C)(2)] PLACE ON AC DISCONNECT <br />AC DISCONNECT8AC PHOTOVOLTAIC POWER SOURCE <br />7 <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DON'T RELOCATE THIS <br />OVERCURRENT DEVICE <br />PLACE THIS LABEL AT P.O.C. TO SERVICE <br />DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL <br />AND SUBPANEL IF APPLICABLE) <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />3 <br />[690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING <br />MEANS WHERE <br />ENERGIZED IN AN OPEN POSITION <br />1 WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />[690.31(D)(2)] PLACE ON JUNCTION BOXES AND <br />CONDUIT EVERY 10' <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM4 <br />[690.56(C)(2)] PLACE ON INVERTER <br />AC DISCONNECT <br />AC PHOTOVOLTAIC POWER SOURCE5MAX AC OPERATING CURRENT: <br />AC OPERATING VOLTAGE: <br /> MAX <br /> VAC240 <br />[690.54] PLACE LABEL AT "INTERACTIVE POINT OF <br />INTERCONNECTION" (AT MAIN SERVICE PANEL AND <br />SUBPANEL IF APPLICABLE) <br />LABELING NOTES: <br />1.1 LABELING REQUIREMENTS BASED ON THE <br />CALIFORNIA ELECTRICAL CODE, <br />CALIFORNIA FIRE CODE 605.11, OSHA STANDARD <br />1910.145, ANSI Z535. <br />1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE <br />AUTHORITY HAVING JURISDICTION. <br />1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br />1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” <br />AND PERMANENTLY AFFIXED. <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />10 <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND <br />CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED <br />ON OR NO MORE THAN 3 FT AWAY FROM SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE <br />CONNECTED AND SHALL INDICATE THE LOCATION OF ALL <br />IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE <br />SAME LOCATION. [690.56(C)] <br />PV SOLAR BREAKER <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />11 <br />LABEL LOCATED INSIDE <br />PANEL NEXT TO PV BREAKER <br />29.04A <br />SUB <br />PANEL <br />5 6JUNCTION <br />BOX <br />METER <br />MAIN SERVICE <br />PANEL1 <br />7 <br />6 8 <br />10 <br />9 <br />INVERTER <br />INTEGRATED <br />DC DISCONNECT <br />4 <br />2 3 <br />1 <br />WHEN <br />APPLICABLE <br />AC <br />DISCONNECT <br />PRODUCTION <br />METER <br />AC <br />DISCONNECT <br />ROOFTOP ARRAY <br />AC LOAD <br />CENTER <br />735835835 <br />5 <br />11 <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />PRODUCTION <br />METER <br />WHEN <br />APPLICABLE <br />RATED FREQUENCY: <br />PHASES: <br />RATING (kW or kVA): <br />AVAILABLE FAULT CURRENT <br />(AT OUTPUT TERMINALS): <br />MAXIMUM OUTPUT AND INPUT CURRENT <br />(AT OUTPUT TERMINALS): <br />MAXIMUM OUTPUT AND INPUT VOLTAGE <br />(AT OUTPUT TERMINALS): <br />UTILITY-INTERACTIVE CAPABLE: <br />FRANKLIN aPOWER X <br />60 Hz <br />L1 / L2 / N / PE <br />5kW <br />20kA <br />24.5A <br />240V <br />YES <br />ENERGY STORAGE <br />SYSTEM DISCONNECT <br />CAUTION <br />THIS PANEL HAS SPLICED FEED- <br />THROUGH CONDUCTORS. <br />LOCATION OF DISCONNECT AT ENERGY <br />STORAGE BACK UP LOAD PANEL. <br />[312.8(A)(3)] PLACE ON MAIN PANEL IF POINT <br />OF INTERCONNECTION IS SUPPLY SIDE <br />CAUTION <br />DO NOT ADD NEW LOADS <br />BACKUP LOAD CENTER <br />[NEC 408.4] PLACE ON BACKUP LOAD CENTER CAUTION <br />TRI POWER SOURCE. <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />THIRD SOURCE IS ENERGY STORAGE SYSTEM <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED WITHIN LINE OF SIGHT <br />PLACE ON MAIN PANEL IF ESS IS IN LINE OF SIGHT <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED ON ADJACENT WALL <br />PLACE ON MAIN PANEL IF ESS IS ON ADJACENT WALL <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED ON OPPOSITE WALL <br />PLACE ON MAIN PANEL IF ESS IS ON OPPOSITE WALL <br />ADDITIONAL PLACARDS FOR ENERGY STORAGE SYSTEM <br />PLACE ON ACCESSIBLE ESS DISCONNECT <br />ONLY 1 REQUIRED <br />[NEC 220] PLACE ON BACKUP LOAD CENTER <br />[705.12(D)(3)] PLACE ON MAIN PANEL IF <br />PV SYSTEM IS ALSO CONNECTED TO PANEL <br />This item has been digitally <br />signed and sealed on <br />03/31/26 <br />Oct 10, 2024 <br />1902 W Monica Ln <br />12/2/2024