My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3428 S Crawford Glen - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Crawford Glen
>
3428 S Crawford Glen
>
3428 S Crawford Glen - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 9:01:37 AM
Creation date
6/30/2025 9:01:28 AM
Metadata
Fields
Template:
Plan
Permit Number
101123954
Full Address
3428 S Crawford Glen
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (6) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (2) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Load Center (2) 3 AWG <br />THHN/THWN-2 <br />(1) 3 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT <br />PAGE <br />REV: B1 6/3/2025 <br />DIANE LE <br />3428 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-428LE <br />SHEET <br />DESIGNER: <br />NITHYA L <br />CUSTOMER RESIDENCE: <br />TEL. (714) 603-8822 <br />APN: 412-531-02 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />MODULE CHARACTERISTICS <br />SILFAB: SIL-430QD-DCA 430 W <br />OPEN CIRCUIT VOLTAGE 38.91 V <br />MAX POWER VOLTAGE 33.25 V <br />SHORT CIRCUIT CURRENT 13.87 A <br />POWER CONTROL SYSTEM (PCS): <br />FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY <br />BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES <br />DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE <br />705.12. <br />ACCORDANCE WITH 240.6(C). <br />SETPOINTS: <br /> <br /> - 80A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL <br /> - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% <br />COMPLIANT) <br />ELECTRICAL <br />CONT. <br />PV-4.1 <br /> ANY MULTIWIRE BRANCH CIRCUITS <br />RELOCATED ARE TO BE IDENTIFIED, GROUPED, <br />AND EQUIPPED WITH A 2-POLE OCPD BREAKER <br />PER CEC 210.4(B,D). <br />TWO GROUNDS RODS OR COLD WATER GAS BOND <br />IF THE RELOCATED LOADS EXTEND MORE <br />THAN 6 FEET, AFCI PROTECTION APPLIES PER <br />2019 CEC 210.12 <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />General Notes: <br />COLD WATER GAS BOND