My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3428 S Crawford Glen - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Crawford Glen
>
3428 S Crawford Glen
>
3428 S Crawford Glen - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 9:01:37 AM
Creation date
6/30/2025 9:01:28 AM
Metadata
Fields
Template:
Plan
Permit Number
101123954
Full Address
3428 S Crawford Glen
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: B1 6/3/2025 <br />DIANE LE <br />3428 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-428LE <br />SHEET <br />DESIGNER: <br />NITHYA L <br />CUSTOMER RESIDENCE: <br />TEL. (714) 603-8822 <br />APN: 412-531-02 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />INVERTER CALCULATIONS <br />EACH INVERTER HAS THE FOLLOWING VALUES WHICH ARE CALCULATED FOLLOWING THESE FORMULAS: <br />INVERTER X: <br />{[((TEMP COEF VOC) X (VOC)) / 100] X (LOW TEMP - STC TEMP) + VOC} * (# MODULES / STRING) <br />INVERTER POWERWALL 3 1707000-XX-Y <br />INVERTER POWERWALL 3 1707000-XX-Y <br />ALLOWABLE BACKFEED: <br /> MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = <br /> MAIN BREAKER RATING = 225 A <br /> 120 A ≤ 225 A INTERCONNECTION <br /> MEETS CEC 2022 705.13 REQUIREMENTSWIRE CALCULATIONS <br />WIRE AMPACITY CALCULATED FROM 310.15(B)(16) & (17) AS APPROPRIATE WITH AMBIENT TEMPERATURE CALCULATIONS FROM 310.15(B)(3)(C) AND RACEWAY FILL <br />ADJUSTMENTS FROM 310.15(B)(3)(A). CONDUIT ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE THE ROOF DECK. PV CIRCUIT CONDUCTOR AMPACITY IS <br />CONSTRAINED USING THE 75°C COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL <br />ADJUSTMENTS WITHOUT THE CONTINUOUS DUTY UPRATING PER 690.8(B), WHICHEVER IS THE LOWER VALUE WILL GOVERN CONDUCTOR SIZING. NON-PV CIRCUIT <br />CONDUCTORS USE THE AMPACITY IN THE 75°C COLUMN OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, <br />WHICHEVER IS LESS (110.14(C) & 310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY <br />UPRATED CURRENT. <br />CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >= OUTPUT CURRENT <br />PV-4.2 <br />ELECTRICAL CALCS
The URL can be used to link to this page
Your browser does not support the video tag.